Andreas Frommhold

Andreas Frommhold

Auto-generated profile, based on publicly available information

Andreas Frommhold

IMEC, Kapeldreef 75, B-3001 Leuven, Belgium

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2024 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
VPVicky Philipsen
Vicky Philipsen
AFAndreas Frommhold
Andreas Frommhold
DTDevesh Thakare
Devesh Thakare
GLGuillaume Libeert
Guillaume Libeert
ILInhwan Lee
Inhwan Lee
EHEric Hendrickx
Eric Hendrickx
We are on the eve of the next big step in lithography technology with the introduction of high numerical aperture EUV. The change from NA 0.33–0.55 in EUV lithography is an increase of 67%, which is the largest jump in the last decades, and puts tight requirements on focus and edge placement. Moreover, the lithography system has changed from fully isomorphic, i.e. same demagnification in all directions, to an anamorphic system, i.e. the demagnification in scan direction has doubled with respect to the slit direction. At imec we are fostering the ecosystem surrounding the lithography tool. In this paper we focus on the imaging and mask innovations supporting the EUV ecosystem, which are categorized into four areas: novel absorber masks, stitching, mask variability, and innovative imaging solutions. The current drivers of IC manufacturers implementing (high NA) EUV lithography (EUVL) are reduction of the EUV exposure dose and decrease in wafer stochastics. We discuss how these four areas have the potential to deliver in EUVL an increase in productivity, an improvement in the process window and a reduction in stochasticity at wafer level.

29 November 2019
Verified
Conference Paper
Closed access
AFAndreas Frommhold
Andreas Frommhold
DCDorin Cerbu
Dorin Cerbu
JBJoost Bekaert
Joost Bekaert
LLLieve Van Look
Lieve Van Look
MMMark J. Maslow
Mark J. Maslow
EHEric Hendrickx
Eric Hendrickx
Stochastic defects have become a major center of attention in EUV lithography as their yield impact poses a potential barrier for future nodes. An important task then is to quantify these stochastic defects, both for process qualification and studying the root causes. Here e-beam provides the most information and sensitivity. However, quantifying defect-free process windows with SEM is not practical for the moment at the million or billion feature level of interest. In this work we propose a method, which maps the entire Focus-Exposure Matrix (FEM) at a relatively low sampling depth (~10,000 contact holes (CH) per condition). This allows to screen for defects based on a limited number of CD measurements as a simple and fast estimate if there is an increased risk for defectivity. With the obtained data we identify potential correlators that link stochastic defects to characteristics of the CD distributions per condition such as Mean CD and LCDU. By fitting the observed trends, we then extrapolate down to the desired failure level and deduce the cut-off value (defect threshold) for the correlator there. To investigate the performance of the correlators we define a failure rate of ‘1 or less’ fails out of one million contacts. With the individual defect thresholds for the failure modes of interest we predict the defect-free region of the FEM where the correlator values are above the determined threshold. An example of this analysis is shown in Figure 1 for a Pitch 40 square contact hole array. As we have no knowledge of the continuation of this trend beyond our measurements, we verify our prediction within the presumed defect-free region by measuring 1 million contact holes for a few select Dose/Focus conditions. We find in general a good agreement between our prediction and the measured dies. The conditions towards the outermost edge of the FEM can exhibit slightly higher defect rates than predicted. Based on these findings together with reports by others that similar trends continue at least down to the 1E-6 level for Line-Space and CH features, we are confident that our approach provides a valuable tool for defectivity analysis. Our compound correlator, which we christened ‘Tail CD’, demonstrates that Mean CD alone is not sufficient to judge a process. Furthermore, we find that the Defect and CD Process Windows are shifted with respect to each other. Hence CD re-targeting is advisable to improve their overlap. We show examples of exercising the proposed method on multiple features types as well as highlighting its use to study the impact of factors such as processing, illumination shape and resist on the observed defectivity correlation trends.

20 March 2015
Verified
Conference Paper
Closed access
PDF file
AFAndreas Frommhold
Andreas Frommhold
ABA G Brown
A G Brown
RPRichard E. Palmer
Richard E. Palmer
TLThomas A Lada
Thomas A Lada
ARAlexander Robinson
Alexander Robinson