Junzhe Wang

Junzhe Wang

Auto-generated profile, based on publicly available information

Junzhe Wang

School of Automation Northwestern Polytechnical University Xi'an China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Jian HuangJian Huang
Jian Huang
JWJunzhe Wang
Junzhe Wang
YTYihua Tan
Yihua Tan
DWDongrui Wu
Dongrui Wu
YCYu Cao
Yu Cao
Since manual inspection of analog instruments is inefficient, many computer vision-based automatic reading systems have been proposed recently. However, most of them use fixed cameras, which are costly due to the large number of used cameras. Although some other systems adopting the pan-tiltzoom camera and the movable inspection robot can avoid using plenty of cameras, they have to overcome high computational cost in aligning the camera to the tested instrument. Meanwhile, most existing systems are instrument type dependent, and hence cannot handle multiple types of instruments simultaneously. In this paper, first, based on an inspection robot, an automatic reading system equipped with a pan-tilt-zoom camera is designed for different types of round-shape analog instruments. Then, a fast camera alignment algorithm based on visual servo is proposed, in which YOLOv3 is applied and improved to locate the instrument, and guide the camera to iteratively align to the instrument. Finally, a monocular-vision pointer reconstruction algorithm is proposed to accurately read the instrument. Experimental results demonstrated that our proposed system is fast and reliable in the camera alignment process, and is effective in reading different types of analog instruments during the robot-based inspection.

1 April 2023 in Highlights in Science, Engineering and Technology
Verified
Journal Article
Open access
PDF file
WMWanli Ma
Wanli Ma
YZYe Zhang
Ye Zhang
JWJunzhe Wang
Junzhe Wang
With the increase of stroke patients, wearable hand rehabilitation exoskeleton devices used to do mechanical rehabilitation training have received attention from researchers. Most of the rigid hand exoskeletons can only perform simple flexion and extension training of the finger as a whole, and not single joint training. Therefore, the subject of this paper is to develop a new multimodal underdriven index finger exoskeleton based on gear drive. The data analysis is compared to achieve the desired specific gesture. This device allows the user to further train the finger and also helps the medical practitioner to better determine the individual joint function of the patient.