Huan Qiu

Huan Qiu

Auto-generated profile, based on publicly available information

Huan Qiu

School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, Singapore

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DZDehong Zhou
Dehong Zhou
HQHuan Qiu
Huan Qiu
SYShunfeng Yang
Shunfeng Yang
YTYi Tang
Yi Tang
Fault diagnosis is indispensable for the reliable operation of modular multilevel converters (MMCs). This paper presents a submodule voltage similarity-based, real-time and fast open-circuit fault diagnosis method for MMCs. The proposed fault detection and location (FDL) method is derived based on the similarity analysis of capacitor voltages under both normal and fault conditions. Due to the absence of the discharging current path caused by the open-circuit fault, capacitor voltage of the SM with the faulty switch will differ from those with healthy switches. This characteristic can be extracted by designing the correlation coefficients of the capacitor voltages at the same arm. With the help of correlation coefficients, the open-circuit fault can be located at the early stage before the capacitor voltage is charged very high. All the data required for the proposed FDL method can be obtained by the available sampled data for the control scheme of MMCs. No extra measurement or hardware is required. Experimental results confirm that the proposed FDL method can detect and locate the open-circuit fault rapidly and accurately within one fundamental period.

27 January 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JWJinyu Wang
Jinyu Wang
XLXiong Liu
Xiong Liu
Qian XiaoQian Xiao
Qian Xiao
DZDehong Zhou
Dehong Zhou
HQHuan Qiu
Huan Qiu
YTYi Tang
Yi Tang

1 September 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HQHuan Qiu
Huan Qiu
JWJinyu Wang
Jinyu Wang
PTPengfei Tu
Pengfei Tu
YTYi Tang
Yi Tang
Modular multilevel converter (MMC) is a promising topology in medium/high-voltage applications for its merits, e.g., scalability, low output current total harmonic distortion, and high efficiency. But the reliability of MMCs is questionable due to more semiconductor devices used than other topologies. Another reliability problem of MMC is the significant uneven loss distribution between the top and bottom semiconductor devices within one submodule (SM) owing to the dc component in the arm currents. The stress difference caused by the uneven loss distribution between the top and bottom semiconductor modules will lead to the lifetime difference of the semiconductor devices, which shortens the lifetime of the whole MMC system. To extend the lifetime of MMCs without the modification of system hardware, this article proposes a device-level loss balancing control method. In this method, the accurate device loss models are established to feedback real-time device losses into the loss balancing controller. The controller (by regulating the SM capacitor voltages) adjusts the semiconductor conducting duty cycles to even the loss distribution without affecting the performance of the ac output and capacitor-voltage balancing. The effectiveness of the proposed control method is validated through experimental results.

18 April 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
DZDehong Zhou
Dehong Zhou
PTPengfei Tu
Pengfei Tu
HQHuan Qiu
Huan Qiu
YTYi Tang
Yi Tang
Open-circuit fault ride-through is indispensable for the reliable operation of modular multilevel converters (MMCs). In this paper, finite-control-set model predictive control (FCSMPC)-based fault detection and isolation (FDI) and fault-tolerant (FT) schemes are proposed for cascaded open-circuit fault ridethrough of MMCs. Taking advantage of the known switching state in FCS-MPC, the errors between the applied and estimated inserted submodule (SM) numbers are utilized for FDI directly. These fault diagnostic signals are independent from the voltage and current ratings, and not sensitive to parameter variations. Moreover, it can locate the fault very fast within a fundamental period. By introducing the healthy state set of the SMs, an FCSMPC strategy with cascaded open-circuit fault ride-through is developed. Switching combinations, which will insert the faulty SMs, are inherently avoided by imposing an additional constraint in the cost function. This integrates the fault ride-through into the control scheme, thereby, resulting in seamless FT operations. The reliability improvement by the proposed fault ride-through scheme is numerically analyzed to present the effectiveness of the proposed method. Experimental results show that open-circuit faults can be detected and isolated within several milliseconds and the cascaded open-circuit faults of MMCs can be seamlessly ridden through by the proposed scheme.

1 September 2018
Verified
Conference Paper
Closed access
DZDehong Zhou
Dehong Zhou
PTPengfei Tu
Pengfei Tu
HQHuan Qiu
Huan Qiu
YTYi Tang
Yi Tang
This paper proposes a model predictive control (MPC) of modular multilevel converters (MMCs) with cascaded open-circuit fault ride-through to improve the reliability of MMCs. Taking advantage of the known switching state in MPC, the open-circuit fault in a submodule (SM) can be detected and isolated within milliseconds by the proposed fault detection and isolation (FDI) scheme. Incorporated with a health state set into MPC, the proposed fault-tolerant control scheme can be integrated into the MPC, and the control of output current, circulating current, and capacitor voltage can be automatically adapted for fault-tolerant operation. Furthermore, the FDI can be reset after one open-circuit fault is isolated, which makes the cascaded multiple open-circuit fault ride-through possible. Experimental results show that fault isolation and system reconfiguration can be completed within several milliseconds and it is possible to seamlessly ride-through cascaded multiple open-circuit faults using the proposed scheme.