Bo Wang

Bo Wang

Auto-generated profile, based on publicly available information

Bo Wang

School of Artificial Intelligence, Hubei University, Wuhan, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BYBo Ye
Bo Ye
ZSZhi Shu
Zhi Shu
BWBo Wang
Bo Wang
SWShufang Wang
Shufang Wang
YFYingbing Fu
Yingbing Fu
SLsheng liu
sheng liu
Wireless Capsule Endoscopy (WCE) allows the screening and diagnosis of a patient’s gastrointestinal tract, including the areas inaccessible to traditional endoscopy, safely and painlessly. However, a large number of images produced in WCE examination require significant time and expertise to process the information and the achieved accuracy is limited due to manual examination by experts. To solve these problems, a novel SE + ResNet-H gastrointestinal lesion recognition model is proposed to automate the screening and detection process. An attention mechanism is added to the original ResNet50 model to form a new attention mechanism + ResNet50 model. Then, transfer learning is integrated with the new attention mechanism + ResNet50 model to classify WCE images. The achieved results in experiment settings involving different combinations of positions and types of added attention mechanisms demonstrate that the average detection accuracy of the optimized improved model can reach up to 97.84% for all types of gastrointestinal images. Subsequently, large-margin cosine loss was used to replace the cross-entropy loss function. Based on the comparative analysis, the improved loss function enhanced the detection accuracy to 98.47% for different types of gastrointestinal images. Furthermore, the results achieved using the Gradient-weighted Class Activation Mapping illustrate that the improved model can capture the focal area well, and promising performance was achieved compared to the original ResNet50 model. The suggested approach can potentially assist endoscopists in the detection and examination of gastrointestinal diseases during endoscopy.

29 August 2025 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
BYBo Ye
Bo Ye
ZSZhi Shu
Zhi Shu
SWShufang Wang
Shufang Wang
BWBo Wang
Bo Wang
GGGuangzheng Gao
Guangzheng Gao
SLsheng liu
sheng liu
With the advancement of capsule endoscopy technology, the treatment of gastrointestinal (GI) tract diseases has entered a new era. Capsule robots enable the diagnosis and treatment of lesions in a painless and minimally invasive manner. Research on highly controllable Drug Delivery Systems (DDSs) using capsule endoscopy is significant for treating GI tract diseases. Despite the variety and complexity of DDS designs, most systems lack the capability for multi-target drug delivery and simultaneous carriage of multiple drugs. This paper proposes a dual-drug-chamber drug delivery capsule robot (DDCR) that utilizes a single Internal Permanent Magnet (IPM) for both drug delivery and propulsion. The design of the dual-drug-chamber primarily aims to carry one or two drugs simultaneously for treating one or multiple target sites. The proposed DDCR uses a balloon mechanism for drug containment. An external magnetic drive system activates a needle attached to a piston, which punctures the balloon and, thereby, releases the medication. This mechanism ensures rapid and effective coverage of lesions by the drugs. Based on both theoretical and experimental results regarding balloon drug loading and the control distance of the external permanent magnet (EPM) control distance, it was established that a drug load of 0.3 ml per chamber was most suitable for the design, and the feasibility of the dosing method was demonstrated. The size (29mm in length and ~13mm in diameter) of the DDCR was also found to be suitable for biological experiments, including multi-target drug delivery. By continuously adjusting the distance between the DDCR and the EPM in porcine small intestine samples, the optimal driving distance and drug delivery distance were found to be 80mm and 140mm.

1 May 2026 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
BYBo Ye
Bo Ye
ZCZuolei Chen
Zuolei Chen
SWShufang Wang
Shufang Wang
SLSixian Liu
Sixian Liu
BWBo Wang
Bo Wang
SLsheng liu
sheng liu