Eran Beit Ner

Eran Beit Ner

Auto-generated profile, based on publicly available information

Eran Beit Ner

Department of Orthopaedics, Shamir (Assaf Harofeh) Medical Center, Zerifin, Israel

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
ENEran Beit Ner
Eran Beit Ner
SDSaad Dosani
Saad Dosani
LBLeela C. Biant
Leela C. Biant
GTGwenllian Fflur Tawy
Gwenllian Fflur Tawy
Background: Failure to accurately replicate the native anatomy and biomechanics of the knee has been suggested to contribute to dissatisfaction after TKA. Custom implants promise a personalized surgical approach, with the aim of improving patient satisfaction and pain as well as lowering revision rates. However, some published research on custom TKA implants has found no clinically important improvements in postoperative validated outcomes scores, risks of revision or reoperation, and implant alignment. In the interest of helping to settle this controversy, a systematic review seems warranted. Question/purpose: In this systematic review, we asked whether custom implants result in clinically important improvements over conventional off-the-shelf implants for anatomically uncomplicated primary TKA in terms of (1) validated outcomes scores, (2) the risk of revision or reoperation, and (3) implant alignment. Methods: The US National Library of Medicine (PubMed/Medline), Embase, Web of Science, and Cochrane Database of Systematic Reviews were systematically searched to identify publications from the past 10 years relevant to this review. Publications that compared the clinical outcome measures, number of revisions and reoperations, and radiological assessment of implant alignment of custom and standard implants with validated endpoints were eligible for inclusion. In the interest of capturing as much potentially relevant information as possible, we applied no requirement for minimum follow-up duration. Clinical outcomes were assessed using patient-reported outcome (PROM) scores including the Knee Society Score (KSS), Forgotten Joint Score, and Knee Injury and Osteoarthritis Outcome Score. The risk for revision or reoperation were evaluated by the number of early and late manipulations, debridement procedures, and replacement of one or more components. Implant alignment was compared using postoperative deviation from the neutral (0°) mechanical axis of the limb and each component and the posterior tibial slope. All qualified studies were retrospective, and all compared custom implants with standard implants. Data on 1510 patients were reviewed (749 with custom implants and 761 with off-the-shelf implants). The mean follow-up time ranged from 12 to 33 months. Results: There was no apparent advantage to custom implants in terms of PROM scores. Of the five studies evaluating clinical outcomes, only one reported better KSS-Function scores at 3 months; two reported no difference, and two found inferior KSS scores. In several studies, custom implants were associated with more frequent reoperations than standard implants. Although in general there were no differences between custom and standard implants in terms of mean coronal plane limb alignment, one of seven studies found that the proportion of patients whose alignment was outside ± 3° from the neutral axis in the coronal plane was lower in the custom group than in the standard group. Conclusion: With generally poorer outcomes scores for pain and function, generally higher risks of reoperation and reintervention, and no overall benefit to alignment, custom implants for primary TKA for the general population currently appear to be inferior to standard implants. Whether the slight reduction in the proportion of patients with alignment outliers observed in a minority of studies will result in a substantial reduction in revision risk over time must be addressed by future studies. However, until or unless such a reduction is proven, we recommend against the routine use of custom implants in practice because of increased costs and the risks associated with their novelty. Level of Evidence: Level III, therapeutic study.

27 October 2020 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
ENEran Beit Ner
Eran Beit Ner
YCYigal Chechik
Yigal Chechik
LLLaura-Ann Lambert
Laura-Ann Lambert
YAYoram Anekstein
Yoram Anekstein
YMYigal Mirovsky
Yigal Mirovsky
YSYossi Smorgick
Yossi Smorgick

20 July 2022 in Injury
Verified
Journal Article
Closed access
AEAhmad Essa
Ahmad Essa
ALAlmog Levi
Almog Levi
TRTzvi Guy Ron
Tzvi Guy Ron
ENEran Beit Ner
Eran Beit Ner
AFAharon S Finestone
Aharon S Finestone
ETEran Tamir
Eran Tamir

29 August 2020 in Journal of Infection Prevention
Verified
Journal Article
Closed access
PDF file
RGRon Gilat
Ron Gilat
IMIlan Y Mitchnik
Ilan Y Mitchnik
ENEran Beit Ner
Eran Beit Ner
NSNoam Shohat
Noam Shohat
ETEran Tamir
Eran Tamir
GAGabriel Agar
Gabriel Agar
Protective lead garments (PLG) worn in the operating room are a potential source for bacterial colonisation and thus may increase the risk of intraoperative infection. The clinical significance of such bacterial contamination has yet been established. Although disinfection protocols have been employed, their effectiveness is also unknown. We sought to describe and compare the bacterial profile of PLGs with a focus on common pathogens involved in surgical site infections (SSI) and prosthetic joint infections (PJI). We studied body aprons and neck-thyroid protective shields. We sampled 20 body aprons and 21 neck PLGs, swabbing the inside and outside of the PLGs. Swabs were cultured on different media and the results were assessed and compared. Of PLGs, 87.8% were contaminated. The neck-thyroid shield PLGs was generally more contaminated than body apron PLGs and exhibited significantly higher loads of Staphylococcus epidermidis (P = 0.048). Other pathogen cultured were Micrococcus spp., Acinetobacter lwoffii (A. lwoffii), Bacillus species (Bacillus spp.), Moraxella osloensis (M. osloensis) and Pseudomonas stutzeri (P. stutzeri). No other common pathogens associated with SSI or PJI were detected. PLGs are heavily contaminated despite regular cleaning protocols. Neck PLGs are highly contaminated with potentially infectious agents. As neck PLGs are often directly exposed above the surgical sterile gown and the surgical field, measures should be undertaken to reduce their exposure and bacterial load, perhaps by suggesting users consider avoiding the use of intraoperative fluoroscopy when possible or alternatively supporting the use of body exhaust suits when PLGs are needed.

15 June 2021 in CARTILAGE
Verified
Journal Article
Closed access
PDF file
YCYigal Chechik
Yigal Chechik
ENEran Beit Ner
Eran Beit Ner
OLOleg Lysyy
Oleg Lysyy
STSigal Tal
Sigal Tal
NSNeta Stern
Neta Stern
DLDror Lindner
Dror Lindner
Objective: While articular cartilage defects are common incidental findings among adult athletes, the effect of running on the cartilage of adolescent athletes have rarely been assessed. This study aims to assess the variations in the articular cartilage of the knees in healthy adolescent basketball players using quantitative T2 MRI (magnetic resonance imaging). Design: Fifteen adolescent basketball players were recruited (13.8 ± 0.5 years old). Girls were excluded to avoid potential gender-related confounding effects. Players underwent a pre-run MRI scan of both knees. All participants performed a 30-minute run on a treadmill. Within 15 minutes after completion of their run, players underwent a second, post-run MRI scan. Quantitative T2 maps were generated using the echo modulation curve (EMC) algorithm. Pre-run scans and post-run scans were compared using paired t test. Results: Participants finished their 30-minute run with a mean running distance of 5.77 ± 0.42 km. Pre-run scans analysis found statistically significant ( P < 0.05) changes in 3 regions of the knee lateral compartment representing the cartilaginous tissue. No differences were found in the knee medial compartment. Post-run analysis showed lower T2 values in the medial compartment compared to the pre-run scans in several weight-bearing regions: femoral condyle central (pre/post mean values of 33.9/32.2 ms, P = 0.020); femoral condyle posterior (38.1/36.8 ms, P = 0.038); and tibial plateau posterior (34.1/31.0 ms, P < 0.001). The lateral regions did not show any significant changes. Conclusions: Running leads to microstructural changes in the articular cartilage in several weight-bearing areas of the medial compartment, both in the femoral and the tibial cartilage.

2 November 2021 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
ENEran Beit Ner
Eran Beit Ner
OROded Rabau
Oded Rabau
SDSaad Dosani
Saad Dosani
UHUri Hazan
Uri Hazan
YAYoram Anekstein
Yoram Anekstein
YSYossi Smorgick
Yossi Smorgick