Peter Irwin

Peter Irwin

Auto-generated profile, based on publicly available information

Peter Irwin

Senior Technical Director, Rowan Williams Davies & Irwin Inc., 600 Southgate Dr., Guelph, Canada N1G 4P6. ORCID:

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2008 in Journal of Wind Engineering and Industrial Aerodynamics
Verified
Journal Article
Closed access
PIPeter A. Irwin
Peter A. Irwin

1 January 2019 in Journal of Structural Engineering
Verified
Journal Article
Closed access
AMAlireza Mohammadi
Alireza Mohammadi
Atorod AzizinaminiAtorod Azizinamini
Atorod Azizinamini
LGLawrence Griffis
Lawrence Griffis
PIPeter Irwin
Peter Irwin
This paper presents a wind performance–based evaluation of an existing 47-story steel moment frame high-rise building designed and built in the early 1970s according to the Houston Building Code in effect at the time with limited wind design criteria (strength requirement under factored wind loads, but no serviceability requirements considered) and no seismic design criteria. The building survived Hurricane Alicia (a Category-3 storm, 1983) without significant structural damage. The nonlinear dynamic response of the building to different wind hazard levels was evaluated by developing a 3D nonlinear finite-element model and using an incremental dynamic analysis (IDA) approach. Using results obtained from the IDA study and using wind performance criteria currently in practice, a wind performance assessment was carried out by evaluating the estimated performance levels as a function of basic wind speed. The results of this study indicated a surprisingly robust lateral capacity associated with the structural nonlinearity that occurred, but confirmed the existence of unacceptable serviceability performance under various levels of wind loading.

1 November 2022 in Natural Hazards Review
Verified
Journal Article
Closed access
PDF file
SLSi Han Li
Si Han Li
PIPeter Irwin
Peter Irwin
ZLZoubir Lounis
Zoubir Lounis
AAAhmed Attar
Ahmed Attar
JDJan Dale
Jan Dale
SBSonia Beaulieu
Sonia Beaulieu
Modern structural design codes assume a statistically stationary climate. However, it is now known that the climate is changing at a rate that calls into question the stationarity assumption. This study was undertaken to explore various methods of accounting for climate nonstationarity. The geographical domain of this study covers most of Canada, intending to explore how best to update future climatic variables in the National Building Code of Canada (NBC). Outputs from future climate simulations for North America by Environment and Climate Change Canada (ECCC) and the Pacific Climate Impacts Consortium (PCIC) were used, focusing on a representative concentration pathway (RCP) scenario, namely the RCP8.5 emissions scenario. Surface hourly mean wind speeds and ground snow amounts were extracted from the simulations and used to detect and quantify trends in the extreme climatic variables from 1950 through 2100. This study reviewed different concepts for evaluating climatic design variables under stationary and nonstationary climates. It was found that within the range of linear nonstationarity detected for grid points within Canada, the results predicted using these nonstationary methods are close. Therefore, a simpler approach, namely Minimax design life level, was adopted to estimate the design wind speeds for 1/50 and 1/500 annual probability of exceedance and the design ground snow loads for 1/50 and 1/1,000 annual probability of exceedance. Design values derived based on nonstationary approaches were compared with the results estimated using the conventional return period concept between 1986 and 2016 and a moving-time-window method between 2060 and 2090 centered at 2075.

1 November 2017 in Engineering Structures
Verified
Journal Article
Closed access
MMMohammadtaghi Moravej
Mohammadtaghi Moravej
PIP. Irwin
P. Irwin
IZI. Zisis
I. Zisis
ACA. Gan Chowdhury
A. Gan Chowdhury
BHB. Hajra
B. Hajra

13 November 2012
Verified
Conference Paper
Closed access
DKDerek Kelly
Derek Kelly
DPDennis Poon
Dennis Poon
PIPeter Irwin
Peter Irwin
JXJiming Xie
Jiming Xie
The Shanghai Center is slated to be the tallest building in China, topping out at a height of 632 m. Due to the tower being situated in a typhoon zone, as well as its height and unusual shape, RWDI undertook a comprehensive wind engineering program. The program included an initial, exploratory set of tests which were done to assist the project team in optimizing the tower's shape and orientation with respect to the prevailing winds. Once the shape had been finalized, detailed tests were conducted which included a pressure study, an aeroelastic model study, and a high-speed Reynold's number test because of the tower's rounded corners. Based on the wind engineering studies, Thornton-Tomasetti was then able to develop an efficient design for the tower that consisted of super-columns with outriggers that work in conjunction with the inner building core, comprising an effective system for resisting wind loads.

1 January 2006
Verified
Conference Paper
Closed access
JXJiming Xie
Jiming Xie
MHMark Hunter
Mark Hunter
PIPeter Irwin
Peter Irwin