16 June 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
X-ray imaging is a widely used imaging modality in the medical diagnostic field due to its availability, low cost, high spatial resolution and fast image acquisition. X-ray photons in standard X-ray sources are polychromatic. Detectors that allow to extract the “colour” information of the individual X-rays can lead to contrast enhancement, improved material identification or reduction of beam hardening artifacts at the system level, if we compare them with the widely spread energy integrating detectors. Today, in the field of Computed Tomography (CT), prototypes of clinical grade systems based on Spectral Photon Counting detectors are currently available for clinical research from different companies. One of the key system components in that development is the X-ray photon detector. This paper reviews the photon detection hardware, from the conversion of X-rays into electrical signals to the pulse processing electronics. A review of available photon counting Application Specific Integrated Circuits (ASICs) for spectroscopic X-ray imaging is presented with emphasis on the CT medical imaging application.
14 June 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
Time-of-flight positron emission tomography (TOF-PET) scanners demand electronics that are power-efficient, low-noise, cost-effective, and possess a large bandwidth. Recent developments have demonstrated sub-100 ps time resolution with elevated power consumption per channel, rendering this unfeasible to build a scanner. In this work, we evaluate the performance for TOF-PET of the FastIC front-end using different scintillators and silicon photomultipliers (SiPMs). FastIC is an 8-channel ASIC developed in CMOS 65 nm capable of measuring the energy and the arrival time of a detected pulse with 12 mW per channel. Using Hamamatsu SiPMs (S13360-3050PE) coupled to LSO:Ce:0.2%Ca crystals of 2 × 2 × 3 mm and LYSO:Ce:0.2%Ca of 3.13 × 3.13 × 20 mm, we measured a CTR of (95 ± 3) ps and 156 ± 4) ps FWHM, respectively. With FBK NUV-HD LF2 M0 SiPMs coupled to the same crystals, we obtained a CTR of (76 ± 2) ps and (127 ± 3) ps FWHM. We employed FastIC with a TlCl pure Cherenkov emitter, demonstrating time resolutions comparable to those achieved with high-power-consuming electronics. These findings shows that FastIC represents a cost-effective alternative that can significantly enhance the time resolution of current TOF-PET systems while maintaining low power consumption.
1 June 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 October 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 January 2019 in Journal of Instrumentation