19 November 2012 in Physical Review B
Raman spectra, supplemented by powder x-ray diffraction and magnetization data of isovalently A- and B-site substituted BiFeO3 in the Bi1$-${}xLaxFeO3 (0$\le${}x$\le${}1), Bi1$-${}xTbxFeO3 (0$\le${}x$\le${}0.2), and Bi0.9Sm0.1Fe1$-${}xMnxO3 (0$\le${}x$\le${}0.3) series, are presented. A good agreement between the structural transitions observed by x-ray diffraction and the vibrational modes observed in the Raman spectra is found over the whole substitutional ranges, and in particular we find spectroscopic signatures of a PbZrO3-type structure for Bi0.8La0.2FeO3. Mode assignments in the substituted materials are made based on Raman spectra of the end-members BiFeO3 and LaFeO3. Moreover, by comparing spectra from all samples with R3c structure, the phonon assignment in BiFeO3 is revisited. A close connection between the degree of octahedral tilt and the Raman shift of the A1 oxygen a$-${}a$-${}a$-${} tilt mode is established. An explanation for the strong second-order scattering observed in Bi1$-${}xLaxFeO3 and Bi1$-${}xTbxFeO3 is suggested, including the assignment of the previously mysterious BiFeO3 mode at 620~cm$-${}1. Finally, the magnetization data indicates a transition from a cycloidal modulated state towards a canted antiferromagnet with increasing A-site substitution, while Bi0.9Sm0.1Fe1$-${}xMnxO3 with x=0 and 0.15 exhibit an anomalous closing of the hysteresis loop at low temperatures. For low A-site substitution levels (x$\le${}0.1) the decreasing Raman intensity of the Fe derived modes correlates with the partial destruction of the spin cycloid as the substitution level increases.
2 October 2018 in Nature Communications
The new European X-ray Free-Electron Laser is the first X-ray free-electron laser capable of delivering X-ray pulses with a megahertz inter-pulse spacing, more than four orders of magnitude higher than previously possible. However, to date, it has been unclear whether it would indeed be possible to measure high-quality diffraction data at megahertz pulse repetition rates. Here, we show that high-quality structures can indeed be obtained using currently available operating conditions at the European XFEL. We present two complete data sets, one from the well-known model system lysozyme and the other from a so far unknown complex of a β-lactamase from K. pneumoniae involved in antibiotic resistance. This result opens up megahertz serial femtosecond crystallography (SFX) as a tool for reliable structure determination, substrate screening and the efficient measurement of the evolution and dynamics of molecular structures using megahertz repetition rate pulses available at this new class of X-ray laser source.
18 November 2019 in Nature Methods
12 April 2019 in Journal of Synchrotron Radiation
The European X-ray Free-Electron Laser (FEL) became the first operational high-repetition-rate hard X-ray FEL with first lasing in May 2017. Biological structure determination has already benefitted from the unique properties and capabilities of X-ray FELs, predominantly through the development and application of serial crystallography. The possibility of now performing such experiments at data rates more than an order of magnitude greater than previous X-ray FELs enables not only a higher rate of discovery but also new classes of experiments previously not feasible at lower data rates. One example is time-resolved experiments requiring a higher number of time steps for interpretation, or structure determination from samples with low hit rates in conventional X-ray FEL serial crystallography. Following first lasing at the European XFEL, initial commissioning and operation occurred at two scientific instruments, one of which is the Single Particles, Clusters and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument. This instrument provides a photon energy range, focal spot sizes and diagnostic tools necessary for structure determination of biological specimens. The instrumentation explicitly addresses serial crystallography and the developing single particle imaging method as well as other forward-scattering and diffraction techniques. This paper describes the major science cases of SPB/SFX and its initial instrumentation – in particular its optical systems, available sample delivery methods, 2D detectors, supporting optical laser systems and key diagnostic components. The present capabilities of the instrument will be reviewed and a brief outlook of its future capabilities is also described.
12 October 2017 in Physical Review Letters
We use extremely bright and ultrashort pulses from an x-ray free-electron laser (XFEL) to measure correlations in x rays scattered from individual bioparticles. This allows us to go beyond the traditional crystallography and single-particle imaging approaches for structure investigations. We employ angular correlations to recover the three-dimensional (3D) structure of nanoscale viruses from x-ray diffraction data measured at the Linac Coherent Light Source. Correlations provide us with a comprehensive structural fingerprint of a 3D virus, which we use both for model-based and ab initio structure recovery. The analyses reveal a clear indication that the structure of the viruses deviates from the expected perfect icosahedral symmetry. Our results anticipate exciting opportunities for XFEL studies of the structure and dynamics of nanoscale objects by means of angular correlations.
28 August 2018 in Nature Communications
X-ray free-electron lasers (XFELs) enable novel experiments because of their high peak brilliance and femtosecond pulse duration. However, non-superconducting XFELs offer repetition rates of only 10–120 Hz, placing significant demands on beam time and sample consumption. We describe serial femtosecond crystallography experiments performed at the European XFEL, the first MHz repetition rate XFEL, delivering 1.128 MHz X-ray pulse trains at 10 Hz. Given the short spacing between pulses, damage caused by shock waves launched by one XFEL pulse on sample probed by subsequent pulses is a concern. To investigate this issue, we collected data from lysozyme microcrystals, exposed to a ~15 μm XFEL beam. Under these conditions, data quality is independent of whether the first or subsequent pulses of the train were used for data collection. We also analyzed a mixture of microcrystals of jack bean proteins, from which the structure of native, magnesium-containing concanavalin A was determined.