Adrian Mancuso

Dr. Adrian Mancuso

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Thomas TschentscherThomas Tschentscher
Thomas Tschentscher
Christian BresslerChristian Bressler
Christian Bressler
JGJan Gruenert
Jan Gruenert
AMAnders Madsen
Anders Madsen
AMAdrian Mancuso
Adrian Mancuso
UZUlf Zastrau
Ulf Zastrau
European XFEL is a free-electron laser (FEL) user facility providing soft and hard X-ray FEL radiation to initially six scientific instruments. Starting user operation in fall 2017 European XFEL will provide new research opportunities to users from science domains as diverse as physics, chemistry, geo- and planetary sciences, materials sciences or biology. The unique feature of European XFEL is the provision of high average brilliance in the soft and hard X-ray regime, combined with the pulse properties of FEL radiation of extreme peak intensities, femtosecond pulse duration and high degree of coherence. The high average brilliance is achieved through acceleration of up to 27,000 electron bunches per second by the super-conducting electron accelerator. Enabling the usage of this high average brilliance in user experiments is one of the major instrumentation drivers for European XFEL. The radiation generated by three FEL sources is distributed via long beam transport systems to the experiment hall where the scientific instruments are located side-by-side. The X-ray beam transport systems have been optimized to maintain the unique features of the FEL radiation which will be monitored using build-in photon diagnostics. The six scientific instruments are optimized for specific applications using soft or hard X-ray techniques and include integrated lasers, dedicated sample environment, large area high frame rate detector(s) and computing systems capable of processing large quantities of data.

12 April 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
AMAdrian Mancuso
Adrian Mancuso
AAAndrew Aquila
Andrew Aquila
LBLewis Batchelor
Lewis Batchelor
RBRichard J. Bean
Richard J. Bean
JBJohan Bielecki
Johan Bielecki
TTThomas Tschentscher
Thomas Tschentscher
The European X-ray Free-Electron Laser (FEL) became the first operational high-repetition-rate hard X-ray FEL with first lasing in May 2017. Biological structure determination has already benefitted from the unique properties and capabilities of X-ray FELs, predominantly through the development and application of serial crystallography. The possibility of now performing such experiments at data rates more than an order of magnitude greater than previous X-ray FELs enables not only a higher rate of discovery but also new classes of experiments previously not feasible at lower data rates. One example is time-resolved experiments requiring a higher number of time steps for interpretation, or structure determination from samples with low hit rates in conventional X-ray FEL serial crystallography. Following first lasing at the European XFEL, initial commissioning and operation occurred at two scientific instruments, one of which is the Single Particles, Clusters and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument. This instrument provides a photon energy range, focal spot sizes and diagnostic tools necessary for structure determination of biological specimens. The instrumentation explicitly addresses serial crystallography and the developing single particle imaging method as well as other forward-scattering and diffraction techniques. This paper describes the major science cases of SPB/SFX and its initial instrumentation – in particular its optical systems, available sample delivery methods, 2D detectors, supporting optical laser systems and key diagnostic components. The present capabilities of the instrument will be reviewed and a brief outlook of its future capabilities is also described.

15 February 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
MVMohammad Vakili
Mohammad Vakili
JBJohan Bielecki
Johan Bielecki
JKJuraj Knoška
Juraj Knoška
FOFlorian Otte
Florian Otte
HHHuijong Han
Huijong Han
JSJoachim Schulz
Joachim Schulz
The Sample Environment and Characterization (SEC) group of the European X-ray Free-Electron Laser (EuXFEL) develops sample delivery systems for the various scientific instruments, including systems for the injection of liquid samples that enable serial femtosecond X-ray crystallography (SFX) and single-particle imaging (SPI) experiments, among others. For rapid prototyping of various device types and materials, sub-micrometre precision 3D printers are used to address the specific experimental conditions of SFX and SPI by providing a large number of devices with reliable performance. This work presents the current pool of 3D printed liquid sample delivery devices, based on the two-photon polymerization (2PP) technique. These devices encompass gas dynamic virtual nozzles (GDVNs), mixing-GDVNs, high-viscosity extruders (HVEs) and electrospray conical capillary tips (CCTs) with highly reproducible geometric features that are suitable for time-resolved SFX and SPI experiments at XFEL facilities. Liquid sample injection setups and infrastructure on the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument are described, this being the instrument which is designated for biological structure determination at the EuXFEL.

25 April 2016 in Scientific Reports
Verified
Journal Article
Open access
CYChun Hong Yoon
Chun Hong Yoon
MYMikhail V. Yurkov
Mikhail V. Yurkov
ESEvgeny A. Schneidmiller
Evgeny A. Schneidmiller
LSLiubov Samoylova
Liubov Samoylova
ABAlexey Buzmakov
Alexey Buzmakov
AMAdrian Mancuso
Adrian Mancuso
The advent of newer, brighter, and more coherent X-ray sources, such as X-ray Free-Electron Lasers (XFELs), represents a tremendous growth in the potential to apply coherent X-rays to determine the structure of materials from the micron-scale down to the Angstrom-scale. There is a significant need for a multi-physics simulation framework to perform source-to-detector simulations for a single particle imaging experiment, including (i) the multidimensional simulation of the X-ray source; (ii) simulation of the wave-optics propagation of the coherent XFEL beams; (iii) atomistic modelling of photon-material interactions; (iv) simulation of the time-dependent diffraction process, including incoherent scattering; (v) assembling noisy and incomplete diffraction intensities into a three-dimensional data set using the Expansion-Maximisation-Compression (EMC) algorithm and (vi) phase retrieval to obtain structural information. We demonstrate the framework by simulating a single-particle experiment for a nitrogenase iron protein using parameters of the SPB/SFX instrument of the European XFEL. This exercise demonstrably yields interpretable consequences for structure determination that are crucial yet currently unavailable for experiment design.

22 February 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
JSJoachim Schulz
Joachim Schulz
JBJ. Bielecki
J. Bielecki
RDR. B. Doak
R. B. Doak
KDK. Dörner
K. Dörner
RGRita Graceffa
Rita Graceffa
AMAdrian Mancuso
Adrian Mancuso
The SPB/SFX instrument of the European XFEL provides unique possibilities for high-throughput serial femtosecond crystallography. This publication presents the liquid-jet sample delivery setup of this instrument. The setup is compatible with state-of-the-art gas dynamic virtual nozzle systems as well as high-viscosity extruders and provides space and flexibility for other liquid injection devices and future upgrades. The liquid jets are confined in a differentially pumped catcher assembly and can be replaced within a couple of minutes through a load-lock. A two-microscope imaging system allows visual control of the jets from two perspectives.

3 December 2023 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
Hitoshi SoyamaHitoshi Soyama
Hitoshi Soyama
XLXiaoyu Liang
Xiaoyu Liang
WYWataru Yashiro
Wataru Yashiro
KKKentaro Kajiwara
Kentaro Kajiwara
EAEleni Myrto Asimakopoulou
Eleni Myrto Asimakopoulou
Alexander KorsunskyAlexander Korsunsky
Alexander Korsunsky
Hydrodynamic cavitation is useful in many processing applications, for example, in chemical reactors, water treatment and biochemical engineering. An important type of hydrodynamic cavitation that occurs in a Venturi tube is vortex cavitation known to cause luminescence whose intensity is closely related to the size and number of cavitation events. However, the mechanistic origins of bubbles constituting vortex cavitation remains unclear, although it has been concluded that the pressure fields generated by the cavitation collapse strongly depends on the bubble geometry. The common view is that vortex cavitation consists of numerous small spherical bubbles. In the present paper, aspects of vortex cavitation arising in a Venturi tube were visualized using high-speed X-ray imaging at SPring-8 and European XFEL. It was discovered that vortex cavitation in a Venturi tube consisted of angulated rather than spherical bubbles. The tangential velocity of the surface of vortex cavitation was assessed considering the Rankine vortex model.