19 March 2023 in Annaly khirurgicheskoy gepatologii = Annals of HPB surgery
Aim. To describe the experience of using augmented reality system in abdominal surgery at one clinical center.Materials and methods. In 2021–2022, five patients underwent laparoscopy with augmented reality technology. The interventions included echinococcectomy with resection of IV, V, VI liver segments, pancreaticoduodenal resection for pancreatic head cancer, excision of mesostenium cyst, resection of pancreas body and tail for neuroendocrine tumor.Results. Application of 3D models requires putting on glasses, scaling and setting a model on the screen image, which sometimes prolonged surgery time to 25 minutes. In a number of operations the use of augmented reality navigated the surgeon when working near vascular structures. After looking through the AR model, a surgeon felt more confident in terms of individual anatomy.Conclusion. Augmented reality can become a reliable and promising tool in abdominal surgery. However, further technological development in augmented reality systems is needed to increase their performance.
8 June 2021 in Journal of Robotic Surgery
23 December 2024 in The International Journal of Medical Robotics and Computer Assisted Surgery
27 June 2025 in Annaly khirurgicheskoy gepatologii = Annals of HPB surgery
Aim. To summarize the experience of applying augmented reality technology in hepatopancreatobiliary surgery.Materials and methods. From November 2021 to January 2024, 43 patients underwent surgery using augmented reality technology. These procedures included pancreatoduodenectomy, distal pancreatectomy, irreversible electroporation of neoplasms, pancreatic pseudocyst removal, resection of the common bile duct with biliodigestive anastomosis formation, atypical liver resections, right hemihepatectomy, and transarterial chemoembolization of hepatic tumor arteries.Results. The use of augmented reality technology showed no significant increase in operative time. In minimally invasive liver procedures, augmented reality proved to be a convenient navigation tool, contributing to reduced fluoroscopy duration and overall operative time. Analysis of Likert scales completed as feedback forms for intraoperative use by the surgical team demonstrated that augmented reality technology was convenient and beneficial for enhancing visualization and navigation.Conclusion. Augmented reality has proven to be an effective, reliable, and promising tool for hepatopancreatobiliary surgery. However, further technological advancements are required to fully realize its potential. Enhancing the performance of augmented reality systems – including their accuracy, stability, and adaptability to various clinical scenarios – will make them more dependable and versatile for a wide range of surgical procedures.
21 October 2026 in Endoscopic Surgery
Objective.To summarize the clinical experience of using augmented reality for preoperative planning and intraoperative navigation across several surgical specialties. Material and methods. From 2022 through 2025, 74 AR-assisted procedures were performed at the University Clinic of the Russian University of Medicine, Ministry of Health of the Russian Federation. The series included procedures in abdominal, interventional, maxillofacial, reconstructive, head and neck, and urologic surgery. Results. Intraoperative setup of the AR system required no more than 15 min and did not materially increase the overall procedure time. Among patients with head and neck tumors, mean operating time was 110±10 min with AR guidance, compared with 130±10 min for comparable procedures performed without AR. Three-dimensional visualization influenced the choice of surgical approach in 5 of 14 patients (35.7%). No perioperative complications were recorded in this group. During transarterial chemoembolization, AR facilitated spatial interpretation of the vascular anatomy. Procedure and fluoroscopy times tended to be shorter, although the differences between groups did not reach statistical significance. Post-procedure Likert-scale ratings provided by the surgical teams supported the system’s usability and its perceived contribution to improved visualization and navigational accuracy. Conclusion. These findings support the clinical feasibility of AR navigation and suggest that it may be particularly useful in anatomically complex regions, in the presence of variant vascular anatomy, and when deep structures are poorly visualized. However, the heterogeneity of the study population and the absence of standardized outcome measures preclude regarding this series as definitive evidence of effectiveness. Further advances will require more accurate segmentation and spatial registration, compensation for intraoperative tissue deformation, and automation of routine model-preparation steps. The authors’ approach to the real-time accumulation of spatially registered ultrasound data represents a promising avenue for addressing some of these limitations.