Yuri V. Poduraev

Yuri V. Poduraev

Auto-generated profile, based on publicly available information

Yuri V. Poduraev

Technobiomed Research Insitute, FSBEI HE ROSUNIMED OF MOH OF RUSSIA,Moscow,Russia

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2019 in Russian Open Medical Journal
Verified
Journal Article
Open access
ACAndrey A. Chunikhin
Andrey A. Chunikhin
EBErnest Bazikyan
Ernest Bazikyan
YPYury V. Poduraev
Yury V. Poduraev
AVAndrey A. Vorotnikov
Andrey A. Vorotnikov
DKDaniil D. Klimov
Daniil D. Klimov
Introduction The development of robotic complexes in various branches of industrial production in recent decades has not left aside medicine. Surgical robotic systems began their development in medical practice with the positioning of endoscopic instruments, allowing to help the surgeon to control the video image of the surgical field and the accuracy of the instrument direction in any laparoscopic surgery [1]. Such systems began to be used in 1995 in performing operations of hip joint replacement based on computed tomography images [2].

17 April 2021
Verified
Book Chapter
Closed access
PDF file
MSMikhail A. Solovyev
Mikhail A. Solovyev
AVAndrei A. Vorotnikov
Andrei A. Vorotnikov
AGAndrey A. Grin
Andrey A. Grin
DKDaniil D. Klimov
Daniil D. Klimov
YPYuri V. Poduraev
Yuri V. Poduraev
VKVladimir V. Krylov
Vladimir V. Krylov

23 December 2024 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
ELEvgenii O. Lopukhov
Evgenii O. Lopukhov
IFIlya A. Frolov
Ilya A. Frolov
MSMikhail A. Solovyev
Mikhail A. Solovyev
LPLeonid S. Prokhorenko
Leonid S. Prokhorenko
DMDenis. S. Mishchenkov
Denis. S. Mishchenkov
OLOleg Levchenko
Oleg Levchenko

8 June 2021 in Journal of Robotic Surgery
Verified
Journal Article
Closed access
PDF file
LPLeonid Prokhorenko
Leonid Prokhorenko
DKDaniil Klimov
Daniil Klimov
AVAndrei Vorotnikov
Andrei Vorotnikov
DMDenis Mishchenkov
Denis Mishchenkov
YPYuri Poduraev
Yuri Poduraev

15 May 2023
Verified
Conference Paper
Closed access
ELEvgenii O. Lopukhov
Evgenii O. Lopukhov
MSMikhail A. Solovyev
Mikhail A. Solovyev
AVAndrei A. Vorotnikov
Andrei A. Vorotnikov
YPYuri V. Poduraev
Yuri V. Poduraev
AGAndrey A. Grin'
Andrey A. Grin'
OLOleg Levchenko
Oleg Levchenko
The main stage of the operation for transpedicular fixation of the spine is the insertion of a pedicular screw into the vertebral body. The main parameters of the neurosurgical process are the value of the torque and the length of the pathway of the screw entry into the vertebral body. Evaluation of these parameters is possible when using a multifunctional wireless device that includes a force-moment and inertial sensors. The data on the torque and angular path are processed according to an algorithm that allows determining the dependence of the torque on the length of the pathway of the pedicular screw into the vertebra. Analyzing the determined dependence during statistical experiments, it becomes possible to find additional parameters of the neurosurgical manipulation. These parameters can be criteria for the quality of neurosurgical manipulation performed or used to assess the strength properties of material. In this paper, a data processing algorithm is given to obtain the dependence of the torque on the length of the pathway of approach of the pedicular screw. The criteria for determining the process of neurosurgical manipulation for the insertion of a pedicular screw are presented, described on the basis of the obtained dependence of the torque on the length of the pathway of the screw.

1 June 2023 in Robotics and Technical Cybernetics
Verified
Journal Article
Closed access
EBEgor Belitsky
Egor Belitsky
MSMikhail Solovyev
Mikhail Solovyev
VKVladislav Kovalsky
Vladislav Kovalsky
AVAndrei Vorotnikov
Andrei Vorotnikov
AKAnton Kordonsky
Anton Kordonsky
DMDepartment of Health of the city of Moscow
Department of Health of the city of Moscow
In the modern world, there is a trend towards the introduction of mechatronics in an increasing number of areas of science and technology in order to solve complex problems of controlling functional movements. One of these problems is the problem of forming surfaces of complex shapes. This task is relevant in many areas of human activity such as industry, art, and human-machine interfaces. However, among the existing solutions, there are none that could provide the possibility of forming complex surfaces under the influence of a load, while providing compact weight-dimensional characteristics. The purpose of this article is to develop the concept of a mechatronic device for the tasks of constructing surfaces of complex shape with high accuracy, the possibility of positioning under a large axial load, and measuring the axial forces exerted by objects of manipulation. The article selects the initial design parameters based on the analysis of devices similar in functionality. Next, the selection of compo-nents, the development of the layout of functional components, control electronics, and design, and the implemen-tation of a 3D model of the final device are carried out. It also describes a method for managing a group of re-ceived mechatronic devices by using a single data bus with a specialized protocol.