Gholamreza Ghorbani Amjad

Gholamreza Ghorbani Amjad

Auto-generated profile, based on publicly available information

Gholamreza Ghorbani Amjad

Department of Orthopedics, School of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2010 in Pakistan Journal of Biological Sciences
Verified
Journal Article
Closed access
AYA. Yavarikia
A. Yavarikia
GAG.G. Amjad
G.G. Amjad
KDK. Davoudpour
K. Davoudpour
The Influence of Tourniquet Use and Timing of its Release on Blood Loss in Total Knee Arthroplasty

1 January 2017
Verified
Closed access
MTMohammad Naghi Tahmasebi
Mohammad Naghi Tahmasebi
GAGholamreza Ghorbani Amjad
Gholamreza Ghorbani Amjad
MKMohammad Hassan Kaseb
Mohammad Hassan Kaseb
KBKaveh Bashti
Kaveh Bashti

15 February 2010 in Pakistan Journal of Biological Sciences
Verified
Journal Article
Closed access
AYAlireza Yavarikia
Alireza Yavarikia
KDKhashayar Davoudpour
Khashayar Davoudpour
GAGholamreza Ghorbani A
Gholamreza Ghorbani A
A Study of the Long Term Effects of Anatomical Open Reduction of Patella on Patellofemoral Articular Cartilage in follow up Arthroscopy

23 January 2025 in Journal of Orthopaedic Reports
Verified
Journal Article
Open access
SSSepehr Shirouei
Sepehr Shirouei
MKMehdi Karimi
Mehdi Karimi
GAGholamreza Ghorbani Amjad
Gholamreza Ghorbani Amjad
MMMorteza Majidi
Morteza Majidi
NSNiyousha Shirsalimi
Niyousha Shirsalimi
AMAbbas Moradi
Abbas Moradi

12 June 2025 in The Journal of Knee Surgery
Verified
Journal Article
Closed access
PDF file
MMMina Mirzaiee
Mina Mirzaiee
BIBehzad Imani
Behzad Imani
GAGholamreza Ghorbani Amjad
Gholamreza Ghorbani Amjad
ASAli Reza Soltanian
Ali Reza Soltanian
MMMaryam Maddineshat
Maryam Maddineshat
Total knee replacement surgery may result in keloids and hypertrophic scars that cause pain and itching. Limited research on wound closure techniques has led to differing opinions among orthopedic surgeons about the best methods to minimize scarring. Our study compares three suture techniques—tandem pulley stitch, modified buried vertical mattress suture (MBVMS), and modified vertical–horizontal mattress suture—alongside subcuticular suture in total knee joint replacement surgeries. A single-blind randomized trial was conducted with 91 candidates for knee replacement surgery at Besat Hospital in Hamadan University of Medical Sciences from June to November 2023. The participants were divided into four groups—three interventions and one control—using a random block design of four. We evaluated the average scores for scar assessment and surgeon satisfaction using the Patient and Observer Scar Assessment Scale (POSAS) and the Visual Analog Scale (VAS). These evaluations were performed at 2 weeks, 6 weeks, and 3 months after the surgery. In each of the four study groups, the scar scores at all time intervals, as evaluated by both surgeons and patients, were lowest (best) for the following groups in order: modified buried vertical mattress, subcuticular, modified vertical-horizontal mattress, and tandem pulley stitch. In each of the four study groups, the VAS score was highest (better) across all time intervals among the patient groups, ranked in the following order: modified buried vertical mattress, subcuticular, modified vertical-horizontal mattress, and tandem pulley stitch. The present study showed that the MBVMS revealed better results in terms of scar scores, as well as surgeon and patient satisfaction. This suture can be a suitable alternative to the subcuticular suture in knee joint replacement surgeries.

17 December 2024 in Health Science Reports
Verified
Journal Article
Open access
VCVahid Chamani
Vahid Chamani
MBMahmood Bahramizadeh
Mahmood Bahramizadeh
MKMobina Khosravi
Mobina Khosravi
ABAkbar Biglarian
Akbar Biglarian
GAGholamreza Ghorbani Amjad
Gholamreza Ghorbani Amjad
MAMokhtar Arazpour
Mokhtar Arazpour
Background and Aims: The patellar tendon‐bearing (PTB) brace is a crucial device designed to lessen axial forces on the tibia. The newly designed PTB brace allows clinicians to measure offloading amount in the realtime. This study aimed to explore the relationship between a rise in displacement between the foot plate and calf shells of this new PTB brace and changes in the amount of offloading on the tibia.Methods: This pilot study used a sample of five individuals with midshaft tibia fractures to investigate the effectiveness of the PTB brace under different conditions. The PTB brace was tested in six different conditions, with the displacement between the foot plate and calf shells varying in increments of 0.5 cm, from 1 cm to 3.5 cm.Results: The new PTB brace provided varying levels of offloading, ranging from 22% to 38%. As the vertical distance between the calf shells and foot plate increased, the offloading levels also increased significantly. The study observed significant differences in weight reduction (p = 0.02) and offloading percentages (p = 0.048) when comparing 1 cm and 1.5 cm displacement.Conclusion: The findings suggest that maintaining a distance of 1.5 cm or more between the calf shells and foot plate is effective in reducing weight and offloading on the tibia. These results have important implications for clinicians using PTB braces to treat tibia fractures, highlighting the importance of adjusting the displacement of the PTB brace to optimize patient outcomes.