The seismic response of structures to strong ground motions is a complex problem that has been studied for decades. However, current seismic regulations do not assess the potential level of damage that a structure may undergo during a given seismic event. This will happen in spite that the design objectives for any structural system are formulated in terms of acceptable levels of damage. This paper develops simple expressions to estimate plastic energy demands for soft soil sites (particularly, those located in Mexico City) capable of generating long duration narrow-banded ground motions. To overcome the limited scope of previous studies, about 35,000 seismic simulations were performed using two scaling methodologies: linear and seismological. A new simplified relation between plastic hysteretic energy and maximum ductility demands is presented, and also, a discussion offered on how this relation can be used to allow for an energy-based design aimed at controlling structural damage under the explicit consideration of low cycle fatigue.
25 September 2015 in Steel and Composite Structures
In recent years, it has been shown that the seismic performance of existing buildings can be enhanced considerably by bracing them with post‐tensioned rods or cables. This upgrading technique has several advantages, which include architectural versatility, low cost and fast construction. Furthermore, it does not add a significant mass to the existing building. The objectives of the present paper are to: investigate the use of post‐tensioned steel bracing for seismic retrofit of non‐ductile reinforced concrete frames with unreinforced masonry infills, discuss some of the issues that need to be addressed in the design of the rehabilitated building, assess the advantages of this rehabilitation technique by studying the seismic performance of an infilled non‐ductile frame building before and after it has been upgraded with post‐tensioned braces, and propose research recommendations.
The use of seismic base-isolation in Mexican projects has increased in the last decade. Particularly, the technology has been used in several buildings with very different characteristics, located in Mexico City. Before 2023, the Mexico City Building Code (MCBC, 2019) did not include in its Complementary Technical Standard for Seismic Design (CTS-SD 2023) requirements for the analysis, design, review and construction of base-isolated structures. Because of this, international design and evaluation standards, such as ASCE 7, EN 1998 and EN 15129, were widely used. Although these international standards are widely acknowledged for their exceptional quality, they do not consider the unique characteristics of Mexico City, including its soft soil conditions and other local factors. To improve the situation, the committee responsible for updating the CTS-SD elaborated and incorporated a new base-isolation chapter into the 2023 edition of this standard. Chapter 13 explicitly establishes the basis for the use of base-isolation in Mexico City, setting a historical precedent as it is the first legal document in the country that addresses this technology. This paper discusses the particularities of the CTS-SD approach for base-isolation in a city that has soils exhibiting a wide variety of dynamic properties. Among the innovative aspects contained in Chapter 13 in relation to international standards are: 1) The definition of a design objectives matrix that relates the minimum required performance for the different seismic intensity levels relevant to the design; 2) The use, for pre-design purposes, of spectral modal dynamic analyses under the consideration of a segmented spectrum that takes into account the different damping levels associated with the fundamental mode and higher modes of vibration; 3) The requirement to carry out a performance-based evaluation to assess the design of base-isolated structures located in the Transitional and Lake Zones of Mexico City; and 4) Specific recommendations to achieve an adequate contrast of lateral stiffness between the superstructure and the isolation system.