Guobao Wang

Guobao Wang

Auto-generated profile, based on publicly available information

Guobao Wang

Department of Radiology, University of California Davis Health, Sacramento, CA, USA

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2014 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GWGuobao Wang
Guobao Wang
JQJinyi Qi
Jinyi Qi
Image reconstruction from low-count positron emission tomography (PET) projection data is challenging because the inverse problem is ill-posed. Prior information can be used to improve image quality. Inspired by the kernel methods in machine learning, this paper proposes a kernel based method that models PET image intensity in each pixel as a function of a set of features obtained from prior information. The kernel-based image model is incorporated into the forward model of PET projection data and the coefficients can be readily estimated by the maximum likelihood (ML) or penalized likelihood image reconstruction. A kernelized expectation-maximization algorithm is presented to obtain the ML estimate. Computer simulations show that the proposed approach can achieve better bias versus variance trade-off and higher contrast recovery for dynamic PET image reconstruction than the conventional maximum likelihood method with and without post-reconstruction denoising. Compared with other regularization-based methods, the kernel method is easier to implement and provides better image quality for low-count data. Application of the proposed kernel method to a 4-D dynamic PET patient dataset showed promising results.

2 August 2012 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GWGuobao Wang
Guobao Wang
JQJinyi Qi
Jinyi Qi
Iterative image reconstruction for positron emission tomography (PET) can improve image quality by using spatial regularization that penalizes image intensity difference between neighboring pixels. The most commonly used quadratic penalty often oversmoothes edges and fine features in reconstructed images. Nonquadratic penalties can preserve edges but often introduce piece-wise constant blocky artifacts and the results are also sensitive to the hyper-parameter that controls the shape of the penalty function. This paper presents a patch-based regularization for iterative image reconstruction that uses neighborhood patches instead of individual pixels in computing the nonquadratic penalty. The new regularization is more robust than the conventional pixel-based regularization in differentiating sharp edges from random fluctuations due to noise. An optimization transfer algorithm is developed for the penalized maximum likelihood estimation. Each iteration of the algorithm can be implemented in three simple steps: an EM-like image update, an image smoothing and a pixel-by-pixel image fusion. Computer simulations show that the proposed patch-based regularization can achieve higher contrast recovery for small objects without increasing background variation compared with the quadratic regularization. The reconstruction is also more robust to the hyper-parameter than conventional pixel-based nonquadratic regularizations. The proposed regularization method has been applied to real 3-D PET data.

21 September 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
GWGuobao Wang
Guobao Wang
ARArman Rahmim
Arman Rahmim
RGRoger N. Gunn
Roger N. Gunn
Positron emission tomography (PET) is actively used in a diverse range of applications in oncology, cardiology, and neurology. The use of PET in the clinical setting focuses on static (single time frame) imaging at a specific time-point post radiotracer injection and is typically considered as semi-quantitative; e.g., standardized uptake value (SUV) measures. In contrast, dynamic PET imaging requires increased acquisition times but has the advantage that it measures the full spatiotemporal distribution of a radiotracer and, in combination with tracer kinetic modeling, enables the generation of multiparametric images that more directly quantify underlying biological parameters of interest, such as blood flow, glucose metabolism, and receptor binding. Parametric images have the potential for improved detection and for more accurate and earlier therapeutic response assessment. Parametric imaging with dynamic PET has witnessed extensive research in the past four decades. In this article, we provide an overview of past and present activities and discuss emerging opportunities in the field of parametric imaging for the future.

1 January 2013 in Theranostics
Verified
Journal Article
Open access
GWGuobao Wang
Guobao Wang
JQJinyi Qi
Jinyi Qi
Dynamic positron emission tomography (PET) can monitor spatiotemporal distribution of radiotracer in vivo. The spatiotemporal information can be used to estimate parametric images of radiotracer kinetics that are of physiological and biochemical interests. Direct estimation of parametric images from raw projection data allows accurate noise modeling and has been shown to offer better image quality than conventional indirect methods, which reconstruct a sequence of PET images first and then perform tracer kinetic modeling pixel-by-pixel. Direct reconstruction of parametric images has gained increasing interests with the advances in computing hardware. Many direct reconstruction algorithms have been developed for different kinetic models. In this paper we review the recent progress in the development of direct reconstruction algorithms for parametric image estimation. Algorithms for linear and nonlinear kinetic models are described and their properties are discussed.

18 November 2021 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
GWGuobao Wang
Guobao Wang
LNLorenzo Nardo
Lorenzo Nardo
MPMamta Parikh
Mamta Parikh
YAYasser G. Abdelhafez
Yasser G. Abdelhafez
ELElizabeth Li
Elizabeth Li
RBRamsey D. Badawi
Ramsey D. Badawi
Quantitative dynamic PET with compartmental modeling has the potential to enable multiparametric imaging and more accurate quantification as compared to static PET imaging. Conventional methods for parametric imaging commonly use a single kinetic model for all image voxels and neglect the heterogeneity of physiological models, which can work well for single-organ parametric imaging but may significantly compromise total-body parametric imaging on long axial field-of-view scanners. In this paper, we evaluate the necessity of voxel-wise compartmental modeling strategies, including time delay correction and model selection, for total-body multiparametric imaging. Methods: Ten subjects (5 patients with metastatic cancer and 5 healthy volunteers) were scanned on the uEXPLORER total-body PET/CT system following injection of 370 MBq 18F-fluorodeoxyglucose (FDG). Dynamic data were acquired for 60 minutes. Total-body parametric imaging was performed using two approaches. One is the conventional method that uses a single irreversible two-tissue compartmental model with and without time delay correction. The second approach selects the best kinetic model from three candidate models for individual voxels. The differences between the two approaches were evaluated for parametric imaging of micro kinetic parameters and FDG net influx rate Ki. Results: Time delay correction had a non-negligible effect on kinetic quantification of various organs and lesions. The effect was larger in lesions with higher blood volume. Parametric imaging of Ki with the standard two-tissue model introduced artifacts in vascular regions, which was overcome by the voxel-wise model selection strategy. Conclusion: The time delay and appropriate kinetic model vary in different organs and lesions. Modeling of the time delay of the blood input function and model selection improved total-body multiparametric imaging.

12 May 2009 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
GWGuobao Wang
Guobao Wang
JQJinyi Qi
Jinyi Qi
Indirect and direct methods have been developed for reconstructing parametric images from dynamic positron emission tomography (PET) data. Indirect methods are simple and easy to implement because reconstruction and kinetic modeling are performed in two separate steps. Direct methods estimate parametric images directly from dynamic PET sinograms and, in theory, can be statistically more efficient, but the algorithms are often difficult to implement and are very specific to the kinetic model being used. This paper presents a class of generalized algorithms for direct reconstruction of parametric images that are relatively easy to implement and can be adapted to different kinetic models. The proposed algorithms use optimization transfer principle to convert the maximization of a penalized likelihood into a pixel-wise weighted least squares (WLS) kinetic fitting problem at each iteration. Thus, it can employ existing WLS algorithms developed for kinetic models. The proposed algorithms resemble the empirical iterative implementation of the indirect approach, but converge to a solution of the direct formulation. Computer simulations showed that the proposed direct reconstruction algorithms are flexible and achieve a better bias-variance tradeoff than indirect reconstruction methods.