3 July 2020 in IEEE Transactions on Industrial Electronics
The speed regulation problem of permanent magnet synchronous motor (PMSM) system is investigated under a non-cascade structure. Despite its superiority in straightforward control design, simple parameter adjustment and satisfying system dynamic performance, the structure brings two problems: the overcurrent protection and unmatched disturbance rejection. Under this structure, the current cannot any more be restricted by a reference value, and ought to be constrained within a certain range to ensure the circuit safety. Besides, unmatched distur- bances, mainly caused by external load torques, may result in undesired interference and even violate the constraint requirement due to their direct effects on the current. Toward that end, a novel overcurrent protection control algorithm is designed to tackle the current constraint and unmatched disturbances simultaneously. A disturbance observer (DOB) is utilized for unmatched disturbance estimation. A constraint coping mechanism is constructed to restrict the current. Then, a key nonlinear item is proposed by augmenting the disturbance estimation and the constrained current. Finally, a composite controller is proposed with concise structure and rigorous closed-loop stability analysis. Numerical and experimental tests further validate that the proposed control approach achieves promising speed tracking performance and guarantees the current constraint in the presence of unmatched disturbances.
31 July 2018 in IEEE Transactions on Industrial Informatics
Under the noncascade structure, a permanent-magnet synchronous motor (PMSM) regulates the speed and current in one loop. On the one hand, fast dynamic performance requires large transient current to provide a high torque. On the other hand, unlike a cascade control, the q -axis current is no longer governed by a reference current signal. In such a system, the nominal controllers cannot guarantee that the q -axis current is within the required range. But an excessively large transient current may threaten the circuit safety. To solve the overcurrent protection problem, the ordinary solution is to choose conservative control parameters, but the dynamic performance inevitably suffers a certain degree of loss. In order to improve this drawback, a simple and effective control scheme is introduced with a current-constrained technique. By constructing a special nonlinear gain, the punishment mechanism for the q -axis current is established in the control action directly. The proposed control approach does not impose limitations on the initial state. Moreover, it has good robustness to load torque uncertainty and undergoes rigorous theoretical analysis. Besides, the proposed current-constrained controller has a very concise structure. It yields a higher reliability of the PMSM control system. Comparative simulation and experimental results between the classic PID and the current-constrained controller on the PMSM servo system verify the feasibility of the presented control scheme.
25 October 2017 in IEEE Transactions on Control Systems Technology
The output voltage tracking problem with overcurrent protection for a pulse width modulation-based dc-dc buck converter is investigated in this brief. On the one hand, large transient current during the start-up phase is required for fast dynamics. On the other hand, overlarge transient current may lead to a risk of hardware damage. Conventionally, this problem is solved by choosing conservative control parameters, while the dynamic performance is sacrificed to a certain extent. Besides, the load uncertainty is inevitable in practical applications. Hence, a control design that keeps a good balance between dynamic performance, overcurrent protection, and robustness is desired. To this end, a novel and simple current-constrained controller is constructed. Both dynamic performance and current constraint are taken into account. The low complexity of the proposed current-constrained controller yields a higher reliability of dc-dc buck converter control system, and reduces cost of hardware. Moreover, it shows a nice property of robustness against load uncertainty. Control action is penalized by adjusting controller gains automatically when inductor current tends to the barrier bound. Rigorous stability analysis is given under the presented controller. Comparative simulation and experimental results between the proposed control scheme and the classic proportion-integration-differentiation control scheme on the buck converter system are illustrated to verify the feasibility and effectiveness of the proposed control scheme.