1 July 2001 in RadioGraphics
Fluoroscopic procedures (particularly prolonged interventional procedures) may involve high patient radiation doses. The radiation dose depends on the type of examination, the patient size, the equipment, the technique, and many other factors. The performance of the fluoroscopy system with respect to radiation dose is best characterized by the receptor entrance exposure and skin entrance exposure rates, which should be assessed at regular intervals. Management of patient exposure involves not only measurement of these rates but also clinical monitoring of patient doses. Direct monitoring of patient skin doses during procedures is highly desirable, but current methods still have serious limitations. Skin doses may be reduced by using intermittent exposures, grid removal, last image hold, dose spreading, beam filtration, pulsed fluoroscopy, and other dose reduction techniques. Proper training of fluoroscopic operators, understanding the factors that influence radiation dose, and use of various dose reduction techniques may allow effective management of patient dose.
17 March 2020 in Radiology
MBMythreyi Bhargavan-Chatfield
Mythreyi Bhargavan-Chatfield
+10
In contrast to the six-fold rise in medical radiation exposure that occurred from 1980 to 2006 in the United States, per capita radiation exposure to the population decreased by 20% between 2006 an... Background Comprehensive assessments of the frequency and associated doses from radiologic and nuclear medicine procedures are rarely conducted. The use of these procedures and the population-based...
9 November 2004 in Circulation
Background—
The purpose of this study was to determine the radiation exposure during catheter ablation of atrial fibrillation (AF) using the pulmonary vein (PV) approach.
Methods and Results—
The study included 15 patients with AF and 5 patients each with atrial flutter and atrioventricular nodal reentrant tachycardia (AVNRT) who underwent fluoroscopically guided procedures on a biplane x-ray system operated at a low-frame pulsed fluoroscopy (7.5 frames per second). Radiation exposure was measured directly with 50 to 60 thermoluminescent dosimeters (TLDs). Peak skin doses (PSDs), effective radiation doses, and risk of fatal malignancies were all computed. Mean fluoroscopy durations for AF procedures were 67.8±21 minutes in the right anterior oblique (RAO) and 61.9±16.6 minutes in the left anterior oblique (LAO) projection, significantly different from that required for atrial flutter and AVNRT. The mean PSDs measured with the TLDs were 1.0±0.5 Gy in the RAO and 1.5±0.4 Gy in the LAO projection. The lifetime risk of excess fatal malignancies normalized to 60 minutes of fluoroscopy was 0.07% for women and 0.1% for men.
Conclusions—
The relatively small amounts of the patient’s radiation exposure in this study, despite the prolonged fluoroscopy durations, can be attributed to the use of very-low-frame pulsed fluoroscopy, the avoidance of magnification, and optimal adjustments of the fluoroscopy exposure rates. The resulting lifetime risk of fatal malignancy is within the range previously reported for standard supraventricular arrhythmias.
1 April 2023 in Radiology
The United States accounts for a large and disproportionate share of global medical radiation procedures and collective effective dose, but use of CT increased more in other countries than in the U... The U.S. National Council on Radiation Protection and Measurements (NCRP) conducted a retrospective assessment of the U.S. data, and the United Nations Scientific Committee on the Effects of Atomic...
1 September 2007 in RadioGraphics
Cardiac imaging with multiple-row detector computed tomography (CT) has become possible due to rapid advances in CT technologies. Images with high temporal and spatial resolution can be obtained with multiple-row detector CT scanners; however, the radiation dose associated with cardiac imaging is high. Understanding the physics of cardiac imaging with multiple-row detector CT scanners allows optimization of cardiac CT protocols in terms of image quality and radiation dose. Knowledge of the trade-offs between various scan parameters that affect image quality--such as temporal resolution, spatial resolution, and pitch--is the key to optimized cardiac CT protocols, which can minimize the radiation risks associated with these studies. Factors affecting temporal resolution include gantry rotation time, acquisition mode, and reconstruction method; factors affecting spatial resolution include detector size and reconstruction interval. Cardiac CT has the potential to become a reliable tool for noninvasive diagnosis and prevention of cardiac and coronary artery disease.
1 April 2009 in Journal of the American College of Radiology