Background: We objectively assessed the optical quality and intraocular scattering by means of parameters provided by a clinical double‐pass system in healthy young subjects and thereby we obtained new reference data for clinical diagnosis. We calculated normal values of neural contrast sensitivity function (nCSF) from the measured modulation transfer function (MTF) and the contrast sensitivity function (CSF). Methods: Eligible subjects were healthy adults aged from 18 to 30 years with a logMAR visual acuity (VA) of 0.0 or better and normal values of CSF. Optical quality measurements for a 4.0 mm pupil were performed using the Optical Quality Analysis System (OQAS) based on the double‐pass technique. The following parameters were analysed: the modulation transfer function cutoff frequency (MTFcutoff), the Strehl2D ratio, the OQAS values (OV) at 100, 20 and nine per cent contrasts and the objective scatter index (OSI). Results: A total of 178 volunteers responded to the call, of whom 181 eyes were finally part of the study taking into account the criteria for inclusion. The values for the optical quality parameters were: 44.54 ± 7.14 cpd (MTFcutoff), 0.27 ± 0.06 (Strehl2D ratio), 1.48 ± 0.24 (OV100%), 1.58 ± 0.32 (OV20%), 1.64 ± 0.39 (OV9%), and 0.38 ± 0.19 (OSI). The nCSF calculated was 1.76 ± 0.21 (3 cpd), 2.13 ± 0.23 (6 cpd), 2.01 ± 0.28 (12 cpd) and 1.86 ± 0.33 (18 cpd). Conclusion: The normal values provided can be a useful tool for discriminating healthy eyes from early abnormal ones in which the optical quality or sensory function is impaired.
Purpose To evaluate objectively intraocular scattering in eyes with nuclear, cortical and posterior subcapsular cataracts by means of an objective scatter index (OSI) obtained from double-pass images. To compare the results with those obtained using clinical conventional procedures. Methods In this prospective, observational, cross-sectional, non-consecutive case series study, 188 eyes with cataracts of 136 patients were analysed (123 eyes had nuclear, 41 eyes had cortical and 24 eyes had posterior subcapsular cataracts). The control group consisted of 117 eyes of 68 healthy patients. Patient examination included subjective refraction, best spectacle-corrected visual acuity (BSCVA), cataract grade using the lens opacities classification system III (LOCS III) and OSI. Results We found a decrease in the BSCVA and an increase in the OSI with increasing cataract grade. Statistically significant differences were observed when the OSI of eyes without cataracts and those with different LOCS III were compared. The comparison between the OSI and LOCS III reported good percentages of agreement regarding the number of eyes classified in equivalent levels: 72.4% (nuclear cataracts), 86.6% (cortical cataracts) and 84.3% (posterior subcapsular cataracts). A non-linear regression model was applied between OSI and BSCVA, which resulted in the following multiple correlation coefficients: r=0.878 (nuclear), r=0.843 (cortical) and r=0.844 (posterior subcapsular). Conclusions The results of the study showed that OSI is a useful parameter for evaluating large amounts of intraocular scattering that can be used, in combination with other conventional procedures, as a valuable tool in clinical practice to grade cataracts objectively.
1 January 2012 in Journal of Cataract & Refractive Surgery
To use a double-pass system to compare the optical quality after photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) for mild to moderate myopia. Universitat Politècnica de Catalunya, Terrassa, Barcelona Institute of Ocular Microsurgery, Barcelona, Spain. Comparative case series. Optical quality was assessed with a clinical double-pass system preoperatively and 3 months after PRK or LASIK. The modulation transfer function (MTF), retinal image quality parameters (MTF cutoff frequency, Strehl ratio), and intraocular scattering (objective scatter index [OSI]) were calculated. This study evaluated 34 eyes that had PRK and 55 eyes that had LASIK. Both PRK and LASIK had a statistically significant impact on retinal image quality, although no significant differences between the techniques were observed. The MTF at 30 cycles per degree decreased by a factor of 1.50 in the PRK group and by a factor of 1.32 in the LASIK group. The MTF cutoff frequency decreased by a factor of 1.04 in the PRK group and by a factor of 1.06 in the LASIK group. The Strehl ratio decreased by a factor of 1.10 and 1.07, respectively. Photorefractive keratectomy and LASIK increased the objective scatter index by factors of 1.48 and 1.57, respectively. Significant correlations between the preoperative refraction and the OSI were found. Retinal image quality was similarly reduced with PRK and LASIK, with no significant differences between the 2 methods. Some PRK patients had a residual refractive error that might have been related to corneal-wound healing still present 3 months postoperatively.
Purpose: To evaluate the eye's optical quality after phakic intraocular lens (IOL) implantation and LASIK for moderate to high myopia. Methods: The retinal image quality of 45 patients was evaluated after undergoing one of three surgical procedures (9 patients with Verisyse IOL [AMO] implants, 11 patients with Veriflex IOL [AMO] implants, and 25 patients who underwent LASIK). Patients were aged <40 years, had at least 5.00 diopters of myopia, and had preoperative best spectacle-corrected visual acuity and postoperative uncorrected visual acuity better than 20/30. The eye's optical quality was measured using the Optical Quality Analysis System (OQAS, Visiometrics S.L.), which is an instrument based on the double-pass technique. Measurements were performed before surgery and 1 day and 1 month after surgery. Results: Optical quality worsened noticeably 1 day after surgery with the Verisyse IOL with a 50% to 60% loss, most likely due to the large incision and the presence of sutures in most eyes. The LASIK technique and Veriflex IOL implant did not cause as remarkable a decrease in optical quality (20% to 25% loss). One month after surgery, the optical quality of patients with IOL implants was high, although some surgically induced astigmatism remained, especially in the Verisyse patients. Conversely, LASIK patients had slightly lower optical quality, with optical parameters that represented 90% of their initial value. Conclusions: Verisyse and Veriflex phakic IOL implantation and LASIK are both safe and effective in correcting moderate to high myopia, but they involve different processes of optical quality recovery. One day after surgery, the Verisyse IOL implantation significantly reduced the eye's optical quality, mainly due to the larger incision required and the higher number of sutures used. This reduction was not as remarkable with the other two techniques. However, 1 month after surgery, patients with IOL implants recovered more optical quality than LASIK patients. [ J Refract Surg. 2009;25:689–698.]
1 November 2010 in Journal of Cataract & Refractive Surgery
To evaluate the effect on vision of laser in situ keratomileusis (LASIK) based on preoperative optical quality. Universitat Politècnica de Catalunya, Terrassa, and Barcelona Institute of Ocular Microsurgery, Barcelona, Spain. Comparative case series. The relative change in optical quality and visual acuity were evaluated in eyes that had LASIK for myopia. The optical quality was assessed before and 3 months after surgery using parameters provided by a double-pass system. Patients were classified into 4 groups by preoperative optical quality: low (Group 1), moderate (Group 2), high (Group 3), and very high (Group 4). The study evaluated 25 patients (50 eyes). The optical quality parameters improved postoperatively in Group 1 and Group 2, with the improvement ranging from 15% to 21% and from 13% to 17%, respectively. The preoperative and postoperative optical quality in Group 3 was similar. The optical quality in Group 4 worsened significantly by percentages ranging from -20% to -26%. Although visual acuity had the same trend, there were no statistically significant changes. The changes in optical quality after LASIK surgery depended on the patient's preoperative optical quality; visual acuity showed the same trend, although no change was significant.
To conduct a clinical validation of a virtual reality-based experimental system that is able to assess the spherical subjective refraction simplifying the methodology of ocular refraction. For the agreement assessment, spherical refraction measurements were obtained from 104 eyes of 52 subjects using three different methods: subjectively with the experimental prototype (Subj.E) and the classical subjective refraction (Subj.C); and objectively with the WAM-5500 autorefractor (WAM). To evaluate precision (intra- and inter-observer variability) of each refractive tool independently, 26 eyes were measured in four occasions. With regard to agreement, the mean difference (±SD) for the spherical equivalent (M) between the new experimental subjective method (Subj.E) and the classical subjective refraction (Subj.C) was -0.034D (±0.454D). The corresponding 95% Limits of Agreement (LoA) were (-0.856D, 0.924D). In relation to precision, intra-observer mean difference for the M component was 0.034±0.195D for the Subj.C, 0.015±0.177D for the WAM and 0.072±0.197D for the Subj.E. Inter-observer variability showed worse precision values, although still clinically valid (below 0.25D) in all instruments. The spherical equivalent obtained with the new experimental system was precise and in good agreement with the classical subjective routine. The algorithm implemented in this new system and its optical configuration has been shown to be a first valid step for spherical error correction in a semiautomated way.