Denture stomatitis is induced by irritation or an inflammatory response when wearing a denture for a long time. Candida species are the leading cause of biofilm formation on the surfaces and fissures of dentures. Thus, this study aimed to formulate and evaluate fluconazole tablets for use in preparing a disinfectant mixture with anticandidal activity. For size enlargement of lactose, a tablet diluent, using polyvinylpyrrolidone (PVP) as an agglomerating agent, was developed to enhance the flowability and compactability of the tablet preparation using direct compression. Lactose agglomerates with 6% PVP were used as a diluent for the fluconazole tablets. Furthermore, other excipients were used, such as a buffering agent, disintegrant, surfactant, and lubricant. The fluconazole tablets obtained could be dispersed and dissolved within 10 min in distilled water to achieve a clear mixture, providing a neutral pH and 96% transmittance. Furthermore, the fluconazole mixtures displayed anticandidal efficiency against C. albicans with a similar effect to the standard fluconazole solution. These findings suggest that the fluconazole-loaded lactose agglomerate tablets show strong potential when prepared using direct compression. The fluconazole mixtures made by dispersing the tablets can be used as a disinfectant for Candida-associated dentures, particularly in patients with oral candidiasis.
A high-performance liquid chromatography method coupled with diode array detection (HPLC-DAD) was developed for simultaneous quantification of andrographolide (AG) and 14-deoxy-11,12-didehydroandrographolide (DDAG) in rat plasma. A salt-assisted liquid–liquid extraction (SALLE) procedure was optimized, with MgSO4 yielding the highest extraction efficiency (>90% for both AG and DDAG), outperforming conventional solvent extraction, and being comparable to solid-phase extraction. The method exhibited acceptable linearity (125–2000 ng/mL, R2 > 0.99), with low limits of detection and quantification of 60 and 70 ng/mL for AG and 201 and 234 ng/mL for DDAG, respectively, while adhering to the ICH M10 criteria for accuracy, precision, and stability under various storage conditions. Stability testing of the prepared samples demonstrated that >99% AG and 95% DDAG were retained when stored at low temperatures, specifically below 4 °C. The developed method was successfully applied in a pharmacokinetic study following oral administration of Andrographis paniculata extract (containing AG 7.5 mg/kg) to healthy Wistar rats. The SALLE-HPLC-DAD method developed herein enables selective AG quantification without significant matrix interference. In conclusion, this study introduces an alternative sample preparation and analytical method that is fast, cost-effective, and reliable, making it suitable for pharmacokinetic studies of the principal biomarker of Andrographis paniculata.
17 May 2025 in International Journal of Biological Macromolecules
A high-performance liquid chromatography method coupled with diode array detection (HPLC-DAD) was developed for the simultaneous quantification of andrographolide (AG) and 14-deoxy-11,12-didehydroandrographolide (DDAG) in rat serum. A salt-assisted liq-uid-liquid extraction (SALLE) procedure was optimized, with MgSO4 yielding the highest extraction efficiency (>90% for both AG and DDAG), outperforming conventional solvent extraction and comparable to solid-phase extraction. The method exhibited acceptable linearity (125–2000 ng/mL, r2 > 0.99), with low limits of detection and quantification of 60 and 70 ng/mL for AG and 201 and 234 ng/mL for DDAG, while adhering to the ICH M10 criteria for accuracy, precision, and stability under various storage conditions. Stability testing of the prepared samples demonstrated that > 99% of AG and 95% of DDAG were retained when stored at low temperatures, specifically below 4 °C. The developed method was successfully applied for a pharmacokinetic study following oral administration of Andrographis paniculata extract (containing AG 7.5 mg/kg) in healthy Wistar rats. The SALLE-HPLC-DAD developed herein enables selective AG quantification without signifi-cant matrix interference. In conclusion, this study introduces an alternate sample prepa-ration and analytical method that is fast, cost-effective, and reliable, making it suitable for pharmacokinetic studies of the principal biomarker of Andrographis paniculata.
10 June 2025 in Journal of Pharmaceutical Innovation