21 November 2025 in IEEE Transactions on Instrumentation and Measurement
The online monitoring of SiC MOSFET gate-oxide degradation presents significant challenges in terms of safety and sensitivity due to the harsh electromagnetic environment and the subtle nature of aging symptoms. To address these challenges, this article proposes a novel non-contact monitoring method for detecting gate-oxide degradation in SiC MOSFETs by extracting the amplitude feature of the turn-on switching oscillation from the gate current. Theoretical analysis reveals that gate-oxide degradation in SiC MOSFETs results in an increase in turn-on time, which subsequently impacts the gate switching oscillation current through the high-frequency (HF) coupling effect of the Miller capacitance. A non-contact monitoring scheme is proposed, utilizing an HF oscillation current sensor and peak detection circuit. To validate the proposed method, an experimental study was conducted on a half-bridge converter equipped with 1.2 kV/30 A SiC MOSFETs. High electric field (HEF) accelerated aging tests were performed under a gate-source voltage condition of Vgs=33 V to investigate the characteristics of gate-oxide degradation. The experimental results demonstrate that the peak of the gate HF switching oscillation current is sensitive to gate-oxide degradation (e.g., 40% before end-of-life), which can be captured online in real-time without interfering with the normal operation of the converter.