Xing Lei

Dr. Xing Lei

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2025 in Electronics
Verified
Journal Article
Open access
PDF file
ZYZhoufei Yao
Zhoufei Yao
XLXing Lei
Xing Lei
XDXizhou Du
Xizhou Du
This paper provides an in-depth review of degradation mechanisms and condition monitoring methods for critical components in modular multilevel converter (MMC) high-voltage direct current (HVDC) systems, including insulated gate bipolar transistors (IGBTs), metallized film capacitors, and cross-linked polyethylene (XLPE) DC cables. This study systematically evaluates the strengths and limitations of existing technologies, while also projecting future trends in technological advancements. By exploring the multi-fields-coupled degradation processes of these components, the mechanisms of switching oscillations, and the flexible and controllable applications of MMC, this review offers valuable insights for improving the accuracy, real-time performance, and reliability of component condition monitoring. The findings aim to contribute to the advancement and broader application of MMC HVDC systems in modern power networks.

23 October 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
ZCZiqian Cheng
Ziqian Cheng
HMHaibao Mu
Haibao Mu
XZXingyu Zou
Xingyu Zou
CSCi Song
Ci Song
RWRenjie Wang
Renjie Wang
Guanjun ZhangGuanjun Zhang
Guanjun Zhang
Frequency domain reflectometry (FDR) based on reflection coefficient spectrum (RCS) is a fast, effective, and non-destructive method for cable defect location. However, due to the impedance mismatch between the tested cable and the signal connection line, as well as multiple reflections of the testing signal within the cable, spurious peaks frequently appear in the location curve, which will affect field judgment and limit the practical applications of FDR. In order to address this issue, an algorithm based on reflection coefficient spectral variational mode decomposition (RCS-VMD) is proposed to improve the conventional cable defect location method based on FDR. The RCS-VMD algorithm determines the order of the RCS decomposition components and identifies the components to be removed based on the principles of VMD. The Pearson correlation coefficient is also introduced as a criterion for removing and reconstructing the VMD components. The simulation and experimental results demonstrate that the improved method can effectively distinguish and eliminate abnormal frequency components caused by the aforementioned factors, thereby suppressing corresponding spurious peaks in the location curve. The peak values of the spurious peaks caused by impedance mismatch at the test terminal and multiple reflections can be reduced by over 90.02%.

21 November 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HLHao Li
Hao Li
ZYZehao Yang
Zehao Yang
DXDawei Xiang
Dawei Xiang
XTXin Tian
Xin Tian
HCHaoyang Cui
Haoyang Cui
XLXing Lei
Xing Lei
The online monitoring of SiC MOSFET gate-oxide degradation presents significant challenges in terms of safety and sensitivity due to the harsh electromagnetic environment and the subtle nature of aging symptoms. To address these challenges, this article proposes a novel non-contact monitoring method for detecting gate-oxide degradation in SiC MOSFETs by extracting the amplitude feature of the turn-on switching oscillation from the gate current. Theoretical analysis reveals that gate-oxide degradation in SiC MOSFETs results in an increase in turn-on time, which subsequently impacts the gate switching oscillation current through the high-frequency (HF) coupling effect of the Miller capacitance. A non-contact monitoring scheme is proposed, utilizing an HF oscillation current sensor and peak detection circuit. To validate the proposed method, an experimental study was conducted on a half-bridge converter equipped with 1.2 kV/30 A SiC MOSFETs. High electric field (HEF) accelerated aging tests were performed under a gate-source voltage condition of Vgs=33 V to investigate the characteristics of gate-oxide degradation. The experimental results demonstrate that the peak of the gate HF switching oscillation current is sensitive to gate-oxide degradation (e.g., 40% before end-of-life), which can be captured online in real-time without interfering with the normal operation of the converter.

13 April 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
CSCi Song
Ci Song
HMHaibao Mu
Haibao Mu
XZXingyu Zou
Xingyu Zou
ZCZiqian Cheng
Ziqian Cheng
KFKaixuan Fan
Kaixuan Fan
Guanjun ZhangGuanjun Zhang
Guanjun Zhang
The travelling wave reflection method is widely used to detect cable defects in modern industrial systems due to its non-destructive nature and high efficiency. However, the overlapping echoes of the defect with short length will result in inaccurate defect evaluation. In view of this, this paper proposes a novel cable defect diagnosis method based on stepped-frequency waveform reflectometry (SFWR) and assisted digital twin technology. First, the frequency response functions (FRFs) of two typical defects: point-like defect and line-like defect are constructed, and the limitations of line loss compensation for evaluating the short line-like defect is analysed. Then, a distinction method based on polarity interval is proposed to determine whether defect echoes exhibit overlapping. Finally, the assisted digital twin technology is used to separate defect overlapping echoes, ensuring the accuracy of defect evaluation. Simulations and experiments show that the method proposed in this paper exhibits good performance in evaluating the line-like defect with short length.