Walan Grizolli

Walan Grizolli

Auto-generated profile, based on publicly available information

Walan Grizolli

Lawrence Berkeley National Laboratory

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2008 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
BGBeatriz Gomes Guimarães
Beatriz Gomes Guimarães
LSLucas Sanfelici
Lucas Sanfelici
RNRegis T Neuenschwander
Regis T Neuenschwander
FRFlávio Rodrigues
Flávio Rodrigues
WGWalan C Grizolli
Walan C Grizolli
Igor PolikarpovIgor Polikarpov
Igor Polikarpov

1 January 2017 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
SUSamuli Urpelainen
Samuli Urpelainen
CSConny Såthe
Conny Såthe
WGWalan Grizolli
Walan Grizolli
MAMarcus Agåker
Marcus Agåker
AHAshley R. Head
Ashley R. Head
FHFranz Hennies
Franz Hennies
SPECIES is an undulator-based soft X-ray beamline that replaced the old I511 beamline at the MAX II storage ring. SPECIES is aimed at high-resolution ambient-pressure X-ray photoelectron spectroscopy (APXPS), near-edge X-ray absorption fine-structure (NEXAFS), X-ray emission spectroscopy (XES) and resonant inelastic X-ray scattering (RIXS) experiments. The beamline has two branches that use a common elliptically polarizing undulator and monochromator. The beam is switched between the two branches by changing the focusing optics after the monochromator. Both branches have separate exit slits, refocusing optics and dedicated permanent endstations. This allows very fast switching between two types of experiments and offers a unique combination of the surface-sensitive XPS and bulk-sensitive RIXS techniques both in UHV and at elevated ambient-pressure conditions on a single beamline. Another unique property of the beamline is that it reaches energies down to approximately 27 eV, which is not obtainable on other current APXPS beamlines. This allows, for instance, valence band studies under ambient-pressure conditions. In this article the main properties and performance of the beamline are presented, together with selected showcase experiments performed on the new setup.

15 June 2020 in Optics Express
Verified
Journal Article
Closed access
DCDaniele Cocco
Daniele Cocco
CHCorey Hardin
Corey Hardin
DMDaniel Morton
Daniel Morton
LLLance Lee
Lance Lee
MNMay Ling Ng
May Ling Ng
GDGuillaume Dovillaire
Guillaume Dovillaire
This article describes the development and testing of a novel, water-cooled, active optic mirror system (called “REAL: Resistive Element Adjustable Length”) that combines cooling with applied auxiliary heating, tailored to the spatial distribution of the thermal load generated by the incident beam. This technique is theoretically capable of sub-nanometer surface figure error control even at high power density. Tests conducted in an optical metrology laboratory and at synchrotron X-ray beamlines showed the ability to maintain the mirror profile to the level needed for the next generation storage rings and FEL mirrors.

14 February 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
TKTomasz Kolodziej
Tomasz Kolodziej
SSStanislav Stoupin
Stanislav Stoupin
WGWalan Grizolli
Walan Grizolli
JKJacek Krzywinski
Jacek Krzywinski
SXShi Xianbo
Shi Xianbo
YSYuri Shvyd'KO
Yuri Shvyd'KO

8 February 2019 in Optics Letters
Verified
Journal Article
Open access
PDF file
WGWalan Grizolli
Walan Grizolli
SXShi Xianbo
Shi Xianbo
LALahsen Assoufid
Lahsen Assoufid
Vibration of optics is one of the major limiting factors of the performance of state-of-the-art beamlines at low-emittance synchrotron facilities. We present a theoretical model with experimental data describing vibration-induced effects on x-ray beam coherence. Owing to the incoherent nature of vibration, the decrease in the beam spatial coherence perturbed by optics vibrations can be characterized by modeling the effective source profile of the vibrating beam. The measurements were carried out by using grating interferometry and a refractive lens with controlled vibration as test optics. The experimental results confirm the model and reveal the dependency of the measured beam spatial coherence on the acquisition time. The proposed method can be used to identify the eigenfrequency of the optical system as well as to optimize beamline operation and experimental conditions for coherence-related techniques.

1 February 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
WGWalan Grizolli
Walan Grizolli
Joakim LaksmanJoakim Laksman
Joakim Laksman
FHFranz Hennies
Franz Hennies
BJBrian Norsk Jensen
Brian Norsk Jensen
RNRalf Nyholm
Ralf Nyholm
RSRami Sankari
Rami Sankari
A high precision five rotation-axes polarimeter using transmission multilayers as polarizers and reflection multilayers as analyzers has been designed and manufactured. To cover the extreme ultraviolet regime, Mo/Si, Cr/C, Sc/Cr, and W/B4C multilayers for transmission and reflection have also been designed and produced. The polarimeter mechanics is supported on a hexapod to simplify the alignment relative to photon beam. The instrument is designed so that it can be easily transferred between different beamlines.