Joakim Laksman

Dr. Joakim Laksman

European X-Ray Free-Electron Laser, Schenefeld, Schleswig-Holstein, Germany
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
TMTheophilos Maltezopoulos
Theophilos Maltezopoulos
FDFlorian Dietrich
Florian Dietrich
WFWolfgang Freund
Wolfgang Freund
UJUlf Fini Jastrow
Ulf Fini Jastrow
AKAndreas Koch
Andreas Koch
JGJan Gruenert
Jan Gruenert

1 October 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
NKNaresh Kujala
Naresh Kujala
WFWolfgang Freund
Wolfgang Freund
JLJia Liu
Jia Liu
AKAndreas Koch
Andreas Koch
TFTorben Falk
Torben Falk
JGJan Grünert
Jan Grünert
The European X-ray Free-Electron Laser Facility in Germany delivers x-ray pulses with femtosecond pulse duration at a repetition rate of up to 4.5 MHz. The free-electron laser radiation is created by the self-amplified spontaneous emission (SASE) process, whose stochastic nature gives rise to shot-to-shot fluctuations in most beam properties, including spectrum, pulse energy, spatial profile, wavefront, and temporal profile. Each spectrum consisting of many spikes varies in width and amplitude that appear differently within the envelope of the SASE spectrum. In order to measure and study the SASE spectrum, the HIgh REsolution hard X-ray single-shot (HIREX) spectrometer was installed in the photon tunnel of the SASE1 undulator beamline. It is based on diamond gratings, bent crystals as a dispersive element, and a MHz-repetition-rate strip detector. It covers a photon energy range of 3 keV–25 keV and a bandwidth of 0.5% of the SASE beam. The SASE spikes are resolved with 0.15 eV separation using the Si 440 reflection, providing a resolving power of 60 000 at a photon energy of 9.3 keV. The measured SASE bandwidth is 25 eV. In this paper, we discuss the design specifications, installation, and commissioning of the HIREX spectrometer. The spectral results using Si (110), Si (111), and C (110) crystals are presented.

15 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSSvitozar Serkez
Svitozar Serkez
WDWinfried Decking
Winfried Decking
LFLars Froehlich
Lars Froehlich
NGNatalia Gerasimova
Natalia Gerasimova
JGJan Gruenert
Jan Gruenert
GGGianluca Geloni
Gianluca Geloni
X-ray pump/X-ray probe applications are made possible at X-ray Free Electron Laser (XFEL) facilities by generating two X-ray pulses with different wavelengths and controllable temporal delay. In order to enable this capability at the European XFEL, an upgrade project to equip the soft X-ray SASE3 beamline with a magnetic chicane is underway. In the present paper we describe the status of the project, its scientific focus and expected performance, including start-to-end simulations of the photon beam transport up to the sample, as well as recent experimental results demonstrating two-color lasing at photon energies of 805 eV + 835 eV and 910 eV + 950 eV. Additionally, we discuss methods to analyze the spectral properties and the intensity of the generated radiation to provide on-line diagnostics for future user experiments.
1

2 August 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
JGJan Grünert
Jan Grünert
MCMarc Planas Carbonell
Marc Planas Carbonell
FDFlorian Dietrich
Florian Dietrich
TFTorben Falk
Torben Falk
WFWolfgang Freund
Wolfgang Freund
OBOleg Brovko
Oleg Brovko

26 March 2015 in Physical Review A
Verified
Journal Article
Open access
PDF file
TBT. Barillot
T. Barillot
CCC. Cauchy
C. Cauchy
PHP.-A. Hervieux
P.-A. Hervieux
MGM. Gisselbrecht
M. Gisselbrecht
SCS. E. Canton
S. E. Canton
FLF. Lépine
F. Lépine
This combined experimental and theoretical study demonstrates that the surface plasmon resonance in C60 alters the valence photoemission quantum phase, resulting in strong effects in the photoelectron angular distribution and emission time delay. Electron momentum imaging spectroscopy is used to measure the photoelectron angular distribution asymmetry parameter that agrees well with our calculations from the time-dependent local density approximation (TDLDA). Significant structure in the valence photoemission time delay is simultaneously calculated by TDLDA over the plasmon active energies. Results reveal a unified spatial and temporal asymmetry pattern driven by the plasmon resonance and offer a sensitive probe of electron correlation. A semiclassical approach facilitates further insights into this link that can be generalized and applied to other molecular systems and nanometer-sized metallic materials exhibiting plasmon resonances.

9 March 2012 in The Journal of Chemical Physics
Verified
Journal Article
Closed access
PDF file
Joakim LaksmanJoakim Laksman
Joakim Laksman
EME. P. Månsson
E. P. Månsson
CGC. Grunewald
C. Grunewald
ASA. Sankari
A. Sankari
MGM. Gisselbrecht
M. Gisselbrecht
SSS. L. Sorensen
S. L. Sorensen
The fragmentation of the doubly-charged carbon dioxide molecule is studied after photoexcitation to the C 1s12πu and O 1s12πu states using a multicoincidence ion-imaging technique. The bent component of the Renner-Teller split states populated in the 1s→ π* resonant excitation at both the carbon and oxygen 1s ionization edges opens pathways to potential surfaces in highly bent geometries in the dication. Evidence for a complete deformation of the molecule is found in the coincident detection of C+ and O2+ ions. The distinct alignment of this fragmentation channel indicates rapid deformation and subsequent fragmentation. Investigation of the complete atomization dynamics in the dication leading to asymmetric charge separation shows that the primary dissociation mechanisms, sequential, concerted, and asynchronous concerted, are correlated to specific fragment kinetic energies. The study shows that the bond angle in fragmentation can extend below 20°.