Jeroen P. M. Peters

Jeroen P. M. Peters

Auto-generated profile, based on publicly available information

Jeroen P. M. Peters

Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht, The Netherlands

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JPJeroen P. M. Peters
Jeroen P. M. Peters
JHJan A. A. van Heteren
Jan A. A. van Heteren
AWAnne W. Wendrich
Anne W. Wendrich
GZGijsbert A. van Zanten
Gijsbert A. van Zanten
WGWilko Grolman
Wilko Grolman
ASAdriana L Smit
Adriana L Smit
Single-sided deafness (SSD) leads to difficulties with speech perception in noise, sound localisation, and sometimes tinnitus. Current treatments (Contralateral Routing of Sound hearing aids (CROS) and Bone Conduction Devices (BCD)) do not sufficiently overcome these problems. Cochlear implants (CIs) may help. Our aim was to evaluate these treatments in a Randomised Controlled Trial (RCT). Adult SSD patients were randomised using a web-based randomisation tool into one of three groups: CI; trial period of ‘first BCD, then CROS’; trial period of ‘first CROS, then BCD’. After these trial periods, patients opted for BCD, CROS, or No treatment. The primary outcome was speech perception in noise (directed from the front (S0N0)). Secondary outcomes were speech perception in noise with speech directed to the poor ear and noise to the better ear (SpeNbe) and vice versa (SbeNpe), sound localisation, tinnitus burden, and disease-specific quality of life (QoL). We described results at baseline (unaided situation) and 3 and 6 months after device activation. 120 patients were randomised. Seven patients did not receive the allocated intervention. The number of patients per group after allocation was: CI (n = 28), BCD (n = 25), CROS (n = 34), and No treatment (n = 26). In S0N0, the CI group performed significantly better when compared to baseline, and when compared to the other groups. In SpeNbe, there was an advantage for all treatment groups compared to baseline. However, in SbeNpe, BCD and CROS groups performed worse compared to baseline, whereas the CI group improved. Only in the CI group sound localisation improved and tinnitus burden decreased. In general, all treatment groups improved on disease-specific QoL compared to baseline. This RCT demonstrates that cochlear implantation for SSD leads to improved speech perception in noise, sound localisation, tinnitus burden, and QoL after 3 and 6 months of follow-up. For most outcome measures, CI outperformed BCD and CROS. Trial registration: Netherlands Trial Register (www.trialregister.nl): NTR4580, CINGLE-trial.

1 January 2020 in Trends in Hearing
Verified
Journal Article
Open access
PDF file
MDMichael F. Dorman
Michael F. Dorman
SNSarah Cook Natale
Sarah Cook Natale
LBLeslie Baxter
Leslie Baxter
DZDaniel M. Zeitler
Daniel M. Zeitler
MCMatthew L. Carlson
Matthew L. Carlson
JNJack H. Noble
Jack H. Noble
Fourteen single-sided deaf listeners fit with an MED-EL cochlear implant (CI) judged the similarity of clean signals presented to their CI and modified signals presented to their normal-hearing ear. The signals to the normal-hearing ear were created by (a) filtering, (b) spectral smearing, (c) changing overall fundamental frequency (F0), (d) F0 contour flattening, (e) changing formant frequencies, (f) altering resonances and ring times to create a metallic sound quality, (g) using a noise vocoder, or (h) using a sine vocoder. The operations could be used singly or in any combination. On a scale of 1 to 10 where 10 was a complete match to the sound of the CI, the mean match score was 8.8. Over half of the matches were 9.0 or higher. The most common alterations to a clean signal were band-pass or low-pass filtering, spectral peak smearing, and F0 contour flattening. On average, 3.4 operations were used to create a match. Upshifts in formant frequencies were implemented most often for electrode insertion angles less than approximately 500°. A relatively small set of operations can produce signals that approximate the sound of the MED-EL CI. There are large individual differences in the combination of operations needed. The sound files in Supplemental Material approximate the sound of the MED-EL CI for patients fit with 28-mm electrode arrays.

17 April 2019 in Audiology and Neurotology
Verified
Journal Article
Open access
PDF file
JPJeroen P.M. Peters
Jeroen P.M. Peters
EBEdwin Bennink
Edwin Bennink
GZGijsbert A. van Zanten
Gijsbert A. van Zanten
Background: In electric-acoustic pitch matching experiments in patients with single-sided deafness and a cochlear implant, the observed “mismatch” between perceived pitch and predicted pitch, based on the amended Greenwood frequency map, ranges from –1 to –2 octaves. It is unknown if and how this mismatch differs for perimodiolar versus lateral wall electrode arrays. Objectives: We aimed to investigate if the type of electrode array design is of influence on the electric-acoustic pitch match. Method: Fourteen patients (n = 8 with CI422 + lateral wall electrode array, n = 6 with CI512 + perimodiolar electrode array; Cochlear Ltd.) compared the pitch of acoustic stimuli to the pitch of electric stimuli at two test sessions (average interval 4.3 months). We plotted these “pitch matches” per electrode contact against insertion angle, calculated from high-resolution computed tomography scans. The difference between these pitch matches and two references (the spiral ganglion map and the default frequency allocation by Cochlear Ltd.) was defined as “mismatch.” Results: We found average mismatches of –2.2 octaves for the CI422 group and –1.3 octaves for the CI512 group. For any given electrode contact, the mismatch was smaller for the CI512 electrode array than for the CI422 electrode array. For all electrode contacts together, there was a significant difference between the mismatches of the two groups (p < 0.05). Results remained stable over time, with no significant difference between the two test sessions considering all electrode contacts. Neither group showed a significant correlation between the mismatch and phoneme recognition scores. Conclusion: The pitch mismatch was smaller for the perimodiolar electrode array than for the lateral wall electrode array.

1 December 2016 in Hearing Research
Verified
Journal Article
Closed access
JPJeroen P.M. Peters
Jeroen P.M. Peters
EBEdwin Bennink
Edwin Bennink
WGWilko Grolman
Wilko Grolman
GZGijsbert A. van Zanten
Gijsbert A. van Zanten

1 July 2018 in Otology & Neurotology
Verified
Journal Article
Closed access
JPJeroen P. M. Peters
Jeroen P. M. Peters
AWAnne W. Wendrich
Anne W. Wendrich
RERuben H. M. van Eijl
Ruben H. M. van Eijl
KRKoenraad S. Rhebergen
Koenraad S. Rhebergen
HVHuib Versnel
Huib Versnel
WGWilko Grolman
Wilko Grolman
Hypothesis: A cochlear implant (CI) restores hearing in patients with profound sensorineural hearing loss by electrical stimulation of the auditory nerve. It is unknown how this electrical stimulation sounds. Background: Patients with single-sided deafness (SSD) and a CI form a unique population, since they can compare the sound of their CI with simulations of the CI sound played to their nonimplanted ear. Methods: We tested six stimuli (speech and music) in 10 SSD patients implanted with a CI (Cochlear Ltd). Patients listened to the original stimulus with their CI ear while their nonimplanted ear was masked. Subsequently, patients listened to two CI simulations, created with a vocoder, with their nonimplanted ear alone. They selected the CI simulation with greatest similarity to the sound as perceived by their CI ear and they graded similarity on a 1 to 10 scale. We tested three vocoders: two known from the literature, and one supplied by Cochlear Ltd. Two carriers (noise, sine) were tested for each vocoder. Results: Carrier noise and the vocoders from the literature were most often selected as best match to the sound as perceived by the CI ear. However, variability in selections was substantial both between patients and within patients between sound samples. The average grade for similarity was 6.8 for speech stimuli and 6.3 for music stimuli. Conclusion: We obtained a fairly good impression of what a CI can sound like for SSD patients. This may help to better inform and educate patients and family members about the sound of a CI.

11 July 2017 in Laboratory Animals
Verified
Journal Article
Open access
PDF file
ABAren Bezdjian
Aren Bezdjian
SKSjaak F L Klis
Sjaak F L Klis
JPJeroen P M Peters
Jeroen P M Peters
WGWilko Grolman
Wilko Grolman
ISInge Stegeman
Inge Stegeman
Research involving animal models is crucial for the advancement of science, provided that experiments are designed, performed, interpreted, and reported well. In order to investigate the quality of reporting of articles in otorhinolaryngology research using animal models, a PubMed database search was conducted to retrieve eligible articles. The checklist of the ARRIVE (Animal Research: Reporting of In Vivo Experiments) guidelines was used to assess the quality of reporting of articles published in ear, nose and throat (ENT) and multidisciplinary journals. Two authors screened titles, abstracts, and full texts to select articles reporting otorhinolaryngology research using in vivo animal models. ENT journals ( n = 35) reported a mean of 57.1% adequately scored ARRIVE items (median: 58.3%; 95% confidence interval [CI; 53.4–60.9%]), while articles published in multidisciplinary journals ( n = 36) reported a mean of 49.1% adequately scored items (median: 50.0; 95% CI [46.2–52.0%]). Articles published in ENT journals showed better quality of reporting of animal studies based on the ARRIVE guidelines ( P < 0.05). However, adherence to the ARRIVE guidelines is generally poor in otorhinolaryngology research using in vivo animal models. The endorsement of the ARRIVE guidelines by authors, research and academic institutes, editorial offices and funding agencies is recommended for improved reporting of scientific research using animal models.