This paper summarizes the technical activities of the Task Force on Power System Dynamic State and Parameter Estimation. This Task Force was established by the IEEE Working Group on State Estimation Algorithms to investigate the added benefits of dynamic state and parameter estimation for the enhancement of the reliability, security, and resilience of electric power systems. The motivations and engineering values of dynamic state estimation (DSE) are discussed in detail. Then, a set of potential applications that will rely on DSE is presented and discussed. Furthermore, a unified framework is proposed to clarify the important concepts related to DSE, forecasting-aided state estimation, tracking state estimation and static state estimation. An overview of the current progress in DSE and dynamic parameter estimation is provided. The paper also provides future research needs and directions for the power engineering community.
30 September 2020 in IEEE Transactions on Power Systems
Power system dynamic state estimation (DSE) remains an active research area. This is driven by the absence of accurate models, the increasing availability of fast-sampled, time-synchronized measurements, and the advances in the capability, scalability, and affordability of computing and communications. This paper discusses the advantages of DSE as compared to static state estimation, and the implementation differences between the two, including the measurement configuration, modeling framework and support software features. The important roles of DSE are discussed from modeling, monitoring and operation aspects for today's synchronous machine dominated systems and the future power electronics-interfaced generation systems. Several examples are presented to demonstrate the benefits of DSE on enhancing the operational robustness and resilience of 21st century power system through time critical applications. Future research directions are identified and discussed, paving the way for developing the next generation of energy management systems and novel system monitoring, control and protection tools to achieve better reliability and resiliency.
Dynamic state estimation (DSE) accurately tracks the dynamics of a power system and provides the evolution of the system state in real-time. This paper focuses on the control and protection applications of DSE, comprehensively presenting different facets of control and protection challenges arising in modern power systems. It is demonstrated how these challenges are effectively addressed with DSE-enabled solutions. As precursors to these solutions, reformulation of DSE considering both synchrophasor and sampled value measurements and comprehensive comparisons of DSE and observers have been presented. The usefulness and necessity of DSE based solutions in ensuring system stability, reliable protection and security, and resilience by revamping of control and protection methods are shown through examples, practical applications, and suggestions for further development.
24 February 2023 in Superconductor Science and Technology
This paper presents a roadmap to the application of AI techniques and big data (BD) for different modelling, design, monitoring, manufacturing and operation purposes of different superconducting applications. To help superconductivity researchers, engineers, and manufacturers understand the viability of using AI and BD techniques as future solutions for challenges in superconductivity, a series of short articles are presented to outline some of the potential applications and solutions. These potential futuristic routes and their materials/technologies are considered for a 10–20 yr time-frame.
14 January 2021 in IEEE Transactions on Industrial Electronics
Existing nonunit protection schemes inevitably require setting, which is a serious problem in practical engineering. Faults occurred at different fault zones will result in different equivalent models, therefore, the fault zone can be determined by recognizing which equivalent model the fault fits well with. In this article, this “model recognition” idea is introduced in fault identification and a “setting-less” protection method is proposed. First, the Peterson equivalent circuits when faults occur at backward external zone, internal zone, and forward external zone are presented, respectively. Accordingly, the corresponding three fault voltage expressions are derived, which are defined as three fault modes. Then, the three fault modes are used to approximate the measured fault voltage using Levenberg-Marquardt optimal approximation method. The fault mode that best fits the measured fault voltage is recognized as the final determined fault mode, which is used for fault identification without setting threshold value. Numerous test studies carried out in Power Systems Computer Aided Design/Electromagnetic Transients including DC (PSCAD/EMTDC) and real-time digital simulator have demonstrated that the proposed method can be utilized for different multiterminal dc systems and is effective under different fault locations, different fault types, and high fault impedances. The proposed method does not require high sampling frequency and has good robustness against measuring noise.
3 January 2018 in IEEE Transactions on Power Delivery
Power systems are experiencing drastic changes with the introduction of renewables and customer owned resources. These changes introduce new challenges in protection, control and operation of power systems. In protection, it is necessary to develop new methods that are immune to the new characteristics and they avoid relay misoperations. In particular, any protection system is vulnerable to hidden failures. This paper introduces a new dynamic state estimation-based centralized protection scheme (DSEBCPS) at a substation level. This system supplements dynamic state estimation-based protection for individual zones known as “setting-less relays” to secure their operation against hidden failures. The DSEBCPS communicates with the setting-less relays via the station bus and obtains essential information from each protection zone, such as phasor quantities and breakers and disconnects status. This information is processed by DSEBCPS to perform dynamic state estimations in the quasi domain once per cycle to detect any sort of abnormality within the substation. Upon detecting abnormalities, the DSEBCPS performs hypothesis testing to distinguish between fault and hidden failure. Its capability to detect hidden failure in real time is used to secure setting-less relays from misoperation, which bridges a critical gap in protection systems. This capability is demonstrated through numerical experiments.