The Laser Interferometer Space Antenna (LISA) and its metrology chain have to fulfill stringent performance requirements to enable the space-based detection of gravitational waves. This implies the necessity of performance verification methods. In particular, the extraction of the interferometric phase, implemented by a phasemeter, needs to be probed for linearity and phase noise contributions. This Letter reports on a hexagonal quasimonolithic optical bench implementing a three-signal test for this purpose. Its characterization as sufficiently stable down to picometer levels is presented as well as its usage for a benchmark phasemeter performance measurement under LISA conditions. These results make it a candidate for the core of a LISA metrology verification facility.
The Laser Interferometer Space Antenna (LISA) aims to observe gravitational waves in the mHz regime over its 10-year mission time. LISA will operate laser interferometers between three spacecrafts. Each spacecraft will utilize independent clocks which determine the sampling times of onboard phasemeters to extract the interferometric phases and, ultimately, gravitational wave signals. To suppress limiting laser frequency noise, signals sampled by each phasemeter need to be combined in postprocessing to synthesize virtual equal-arm interferometers. The synthesis in turn requires a synchronization of the independent clocks. This article reports on the experimental verification of a clock synchronization scheme down to LISA performance levels using a hexagonal optical bench. The development of the scheme includes data processing that is expected to be applicable to the real LISA data with minor modifications. Additionally, some noise coupling mechanisms are discussed.
Laser interferometers are the core measurement tool in gravitational wave observatories. An important factor that can limit the performance is the relative power instability of the laser, a problem often called relative intensity noise (RIN). But exactly how this influences the interferometer performance is not completely understood. Therefore in this paper we analyze laser RIN coupling into the phase readout in balanced and unbalanced heterodyne interferometers. We describe the coupling theoretically, then simulate and finally measure it. Our results reveal a combination of RIN contributions from the heterodyne frequency and twice the heterodyne frequency in the interferometric phase readout. We also show that when an additional, correlated reference measurement is subtracted the combined coupling factor depends on the differential phase between the two measurements and thus can be minimized. Our results have implications for noise models in future space-based gravitational wave observatories like Laser Interferometer Space Antenna, where RIN-to-phase coupling arises directly and is modulated via spacecraft jitter, testmass position and orientation.
The Laser Interferometer Space Antenna (LISA) is a gravitational wave detector in space. It relies on a postprocessing technique named time-delay interferometry to suppress the overwhelming laser frequency noise by several orders of magnitude. This algorithm requires intersatellite-ranging monitors to provide information on spacecraft separations. To fulfill this requirement, we use on-ground observatories, optical sideband-sideband beatnotes, pseudorandom noise ranging (PRNR), and time-delay interferometric ranging (TDIR). This article reports on the experimental end-to-end demonstration of a hexagonal optical testbed used to extract absolute ranges via the optical sidebands, PRNR, and TDIR. These were applied for clock synchronization of optical beatnote signals sampled at independent phasemeters. We set up two possible PRNR processing schemes: Scheme 1 extracts pseudoranges from PRNR via a calibration relying on TDIR; Scheme 2 synchronizes all beatnote signals without TDIR calibration. The schemes rely on newly implemented monitors of local-PRNR biases. After the necessary PRNR treatments (unwrapping, ambiguity resolution, bias correction, in-band jitter reduction, and/or calibration), Schemes 1 and 2 achieved ranging accuracies of 2.0–8.1 cm and 5.8–41.1 cm, respectively, below the classical 1-m mark with margins. Published by the American Physical Society 2024
We present the development of an advanced phasemeter for the deep phase modulation interferometry technique. This technique aims for precise length measurements with a high dynamic range using little optical hardware. The advanced phasemeter uses fast ADCs and an FPGA to implement a design of multiple single-bin Fourier transforms running at high sampling rates. Non-linear noise sources in the design were analyzed and suppressed. A null measurement with an optical beatnote signal using λ = 1064nm was conducted. It showed a sensitivity of below 10Hz and above, with a large dynamic range. The shown performance could enable the measuring of optical path lengths with sensitivities down to and , respectively, over several fringes in an interferometric setup.
Tracking moving masses in several degrees of freedom with high precision and large dynamic range is a central aspect in many current and future gravitational physics experiments. Laser interferometers have been established as one of the tools of choice for such measurement schemes. Using sinusoidal phase modulation homodyne interferometry allows a drastic reduction of the complexity of the optical setup, a key limitation of multi-channel interferometry. By shifting the complexity of the setup to the signal processing stage, these methods enable devices with a size and weight not feasible using conventional techniques. In this paper we present the design of a novel sensor topology based on deep frequency modulation interferometry: the self-referenced single-element dual-interferometer (SEDI) inertial sensor, which takes simplification one step further by accommodating two interferometers in one optic. Using a combination of computer models and analytical methods we show that an inertial sensor with sub-picometer precision for frequencies above 10 mHz, in a package of a few cubic inches, seems feasible with our approach. Moreover we show that by combining two of these devices it is possible to reach sub-picometer precision down to 2 mHz. In combination with the given compactness, this makes the SEDI sensor a promising approach for applications in high precision inertial sensing for both next-generation space-based gravity missions employing drag-free control, and ground-based experiments employing inertial isolation systems with optical readout.