Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Montefiore Health System, Albert Einstein College of Medicine , 111 E 210th street, Bronx, NY 10467
Auto-generated profile, based on publicly available information
Aung Lin
Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Montefiore Health System, Albert Einstein College of Medicine , 111 E 210th street, Bronx, NY 10467
Pulsed-field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt electrogram (EGM) signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. The aim of this study is to check whether application repetition and catheter–tissue contact impact lesion formation during PFA. A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 h in the vegetal model and over 6 h in the porcine model. Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 and 4.4 ± 1.3 mm, respectively (P = 0.002). Furthermore, the greater the catheter–tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0 ± 0.9 mm with no contact vs. 5.4 ± 1.4 mm with 30 g of force; P = 0.0001). Pulsed-field ablation delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA are related more to PFA biophysics than to mere EGM attenuation.
An integrative taxonomic analysis based on morphology, color pattern, and the mitochondrial gene ND2 recovered four new species of Hemiphyllodactylus Bleeker that are endemic to the Shan Plateau or Salween Basin in eastern Myanmar. Hemiphyllodactylus ngwelwini sp. nov. from the Shan Plateau is part of the earlier described “eastern Myanmar clade” renamed herein as the north lineage and H. kyaiktiyoensis sp. nov. and H. pinlaungensis sp. nov. of the Shan Plateau and H. zwegabinensis sp. nov. of the Salween Basin compose an entirely new Burmese clade herein referred to as the south lineage. Although the north and south lineages come within 46 km of one another on the Shan Plateau, they are not sister lineages but sequentially separated by two lineages from Yunnan, China and another from northwestern Thailand. Hemiphyllodactylus zwegabinensis sp. nov. is the first species of this genusto be recorded from the Salween Basin and is known only from a wind-blown cloud forest on the top of the insular, karstic mountain Zwegabin in Kayin State. All other Burmese species except for H. typus, are endemic to the various localities throughout the Shan Plateau. These four new species bring the total number of Hemiphyllodactylus in Myanmar to at least 10 which is certainly an extreme underestimate of the diversity of this genus given that we discover new species at every upland locality we survey.
Lizards and snakes (squamates) are known for their varied sex determining systems, and gecko lizards are especially diverse, having evolved sex chromosomes independently multiple times. While sex chromosomes frequently turnover among gecko genera, intrageneric turnovers are known only from Gekko and Hemidactylus. Here, we used RADseq to identify sex-specific markers in two species of Burmese bent-toed geckos. We uncovered XX/XY sex chromosomes in Cyrtodactylus chaunghanakwaensis and ZZ/ZW sex chromosomes in Cyrtodactylus pharbaungensis. This is the third instance of intrageneric turnover of sex chromosomes in geckos. Additionally, Cyrtodactylus are closely related to another genus with intrageneric turnover, Hemidactylus. Together, these data suggest that sex chromosome turnover may be common in this clade, setting them apart as exceptionally diverse in a group already known for diverse sex determination systems.
10 December 2020 in Circulation: Arrhythmia and Electrophysiology
Background: We have previously shown that the presence of dual muscular coronary sinus (CS) to left atrial (LA) connections, coupled with rate-dependent unidirectional block in one limb, is associated with atrial fibrillation (AF) induction. This study sought to examine whether ablation of distal CS to LA connections at a first AF ablation reduces arrhythmia recurrence during follow-up. Methods: In this single-center, randomized, controlled trial, 35 consecutive patients with drug-refractory AF undergoing first-time ablation between August 2018 and August 2019, were randomly assigned to (1) standard ablation (pulmonary vein isolation and nonpulmonary vein trigger ablation) versus (2) standard ablation plus elimination of distal CS to LA connections targeting the earliest LA activation during distal CS pacing with a deca-polar catheter placed with its proximal electrode at the ostium. Change of the local CS atrial electrogram and LA activation sequence to early activation of the LA septum or roof during distal CS pacing were the end point for CS-LA connection elimination. Results: Thirty patients completed 6 months study follow-up (15 patients in each group). Demographic characteristics including age and AF persistence were similar in both groups. After a mean follow-up of 170±22 days, there were 7 atrial arrhythmia recurrences in the standard group and 1 recurrence in the CS-LA connection elimination group (46.7% versus 6.7%, hazard ratio, 0.12, P =0.047). Conclusions: Elimination of distal CS to LA connections reduced atrial arrhythmia recurrences compared with standard pulmonary vein isolation and nonpulmonary vein trigger ablation in patients undergoing a first AF ablation procedure in a small randomized study. This strategy warrants further evaluation in a multicenter randomized trial. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03646643.
Patients with typical atrial flutter (AFL) undergoing successful cavotricuspid isthmus ablation remain at risk for future development of new-onset atrial fibrillation (AF). Conventional monitoring (CM) techniques have shown AF incidence rates of 18%–50% in these patients. To evaluate whether continuous monitoring using implantable loop recorders (ILRs) would enhance AF detection in this patient population. Veteran patients undergoing AFL ablation between 2002 and 2019 who completed at least 6 months of follow-up after the ablation procedure were included. We compared new-onset AF detection between those who underwent CM and those who received ILRs immediately following AFL ablation. A total of 217 patients (age: 66 ± 9 years; all male) participated. CM was used in 172 (79%) and ILR in 45 (21%) patients. Median follow-up duration after ablation was 4.1 years. Seventy-nine patients (36%) developed new-onset AF, which was detected by CM in 51 and ILR in 28 (30% vs 62%, respectively, P < .001). AF detection occurred at 7.7 months (IQR: 4.7–17.5) after AFL ablation in the ILR group vs 41 months (IQR: 23–72) in the CM group (P < .001). Eleven patients (5%) experienced cerebrovascular events (all in the CM group) and only 4 of these patients (36%) were on long-term anticoagulation. Patients undergoing AFL ablation remain at an increased risk of developing new-onset AF, which is detected sooner and more frequently by ILR than by CM. Improving AF detection may allow optimization of rhythm management strategies and anticoagulation in this patient population.