6 September 2018 in Geophysical Research Letters
We tested the performance of an infrasonic array consisting of three microphones with a 20‐m aperture at Stromboli volcano, Italy. There were four active vents separated by ∼10∘. We employed multiple signal classification (MUSIC) to estimate direction of arrival (DOA) of the detected signals. Using test signals of which the source vents were identified by visual observation, the resolution of DOA estimation of MUSIC is compared with those of Capon beamforming, grid search, and semblance. We confirmed that MUSIC and grid search gave better resolution of DOA than the other two methods. Also, MUSIC provided the best resolutions in time and frequency. It was shown that the DOA switched between different vents or fluctuated in short time scales and can vary with frequency, which indicate multiple active sources. Possible DOA estimation errors were evaluated. A small aperture infrasonic array combined with MUSIC will become a powerful tool for studying and monitoring active volcanoes.
24 September 2021 in Earth, Planets and Space
A volcanic eruption transmits both seismic and infrasound signals. The seismo-acoustic power ratio is widely used to investigate the eruption behaviors and the source dynamics. It is often the case that seismic data during an eruption are significantly contaminated or even dominated by ground shaking due to infrasound (air-to-ground signals). To evaluate the contribution of infrasound-originated power in the seismic data, we need a response function of the seismic station to infrasound. It is rare to obtain a seismo-acoustic data set containing only infrasound signals, though it is ideal for calculating the response function. This study proposes a simple way to calculate the response function using seismo-acoustic data containing infrasound and independent seismic waves. The method requires data recorded at a single station and mainly uses the cross-correlation function between the infrasound data and the Hilbert transform of the seismic data. It is tested with data recorded by a station at Kirishima volcano, Japan, of which response function has been constrained. It is shown that the method calculates a proper response function even when the seismic data contain more significant seismic power (or noise) than the air-to-ground signals. The proposed method will be useful in monitoring and understanding eruption behaviors using seismo-acoustic observations.
7 December 2021 in Geophysical Journal International
SUMMARY: This study tested a very-small-aperture 3-D (VSA-3D) infrasonic array. A 3-D array is ideal for resolving the back elevation angle (BEL), which has become important in the analysis of volcanic jet noise or geological flows on steep mountain slopes. Although a VSA infrasonic array, with an aperture as small as a few tens of metres, has recently been shown to have a sufficient resolution of the backazimuth (BAZ) of incident signals, its BEL resolution is considered to be poor. We performed a four-element 3-D array experiment with a 20-m aperture and 2-m height at the summit of Stromboli Volcano. We analysed the direction of arrival (DOA) with the MUSIC algorithm as a function of frequency and conducted a cluster analysis for the estimated DOA–frequency functions of eruption signals. As a result, individual infrasonic signals were successfully related to eruptive vents. We also calculated the standard deviation (STD) of the DOAs in each cluster. Of the observed BAZ-STDs and BEL-STDs, 80 per cent were <2.0° and <4.6°, respectively. A comparison among the array geometries showed that the installation of a sensor above the ground, even at only 2 m, improved the BEL resolution, indicating that the VSA-3D array provides more detailed information about the wavefield than a planar array. The observed signals had higher BELs (−20° to 0°) than the vent direction (−30° to −25°) at 3–6 Hz, although signals above 20 Hz arrived from the vent direction. Our array verified that such DOA deviations were significant by the STD analysis and some tests with synthetic data. We infer that the DOA deviations do not indicate the source location and are caused by topographical diffraction.
21 February 2023 in Earth, Planets and Space
In the infrasonic observation of a fumarolic field, distinguishing multiple fumarolic sources is challenging. The array technique effectively estimates the source locations and identifies the target signal from other signals and noise. We conducted an experiment at Kirishima Iwo-Yama, Japan, where two active fumarolic areas were separated by ~ 450 m. A three-element array with an aperture of ~ 20 m was installed between the two fumarolic areas. In addition, a single microphone was installed near one of the fumaroles. The array combined with the waveform correlation analysis estimated the most prominent source but failed to estimate the other weak source. A joint analysis of the array and the single microphone effectively resolved the two sources. It was also confirmed that newly developed power-saving MEMS microphones were useful for observing the fumaroles. This paper presents the instrumentation and analytical method that would be beneficial for monitoring volcanoes that have multiple hydrothermally active vents. Graphical Abstract
17 May 2022 in Research Square
In the infrasonic observation of fumarolic area, the challenge is to distinguish among the multiple fumarolic sources and noise. The array technique effectively estimates the source locations and identifies the target signal from others and noise. We conducted the experiment at Kirishima Iwo-yama, Japan, where there are two fumarolic craters separated by about 450 m. A three-element array with an aperture of 20 m was installed between two targeting fumaroles. In addition, a single microphone was installed near one of the fumaroles. The array with the waveform correlation analysis estimated the most prominent source but failed to estimate the other weak source. The joint analysis of the array and the single microphone effectively resolved the two sources. The method developed by this experiment would be beneficial for monitoring volcanoes that hold hydrothermally active multiple vents.
21 May 2025 in Earth, Planets and Space
The infrasonic array technique is applied in many volcanoes to locate the acoustic source. Compared to the azimuthal estimation for the horizontal source location information, the elevational estimation is challenging due to the difficulty of aligning sensors vertically. However, the elevational estimation is essential because volcanic eruptions often have infrasound sources distributed at different heights, such as a pyroclastic density current on a steep slope or a volcanic jet. A previous study, which conducted an infrasonic array experiment at Stromboli Volcano, obtained frequency-dependent source elevation, which they concluded to be due to the topographic effect on the apparent slowness along the ground. We examined the topographic effects on the apparent slowness by numerical simulations for acoustic propagation with the 2D axisymmetric finite element method. The simplification in 2D allowed us to examine the individual topographic elements around the vent and the array site at Stromboli Volcano. The mountain summit topography behind the array distorted acoustic phases, causing an underestimation of the slowness below 10 Hz, which led to an apparent source at ≥ 100 m above the vent. On the other hand, frequencies above 20 Hz pointed to the right elevations. The comparison between the simulated and observed slowness-frequency relations indicated that the source was within 30 m above the vent. We infer that turbulence in the atmosphere significantly above the vent should not be a primary source in the previous observation at Stromboli. We emphasize that considering the topographic effects is necessary to avoid misunderstanding the source location. Graphical Abstract