Crustal earthquake ruptures tend to initiate near fluid-rich zones. However, it is relatively unknown whether fluid-rich zones can further promote or arrest these ruptures. We image the electrical resistivity structure around the focal area of the 2016 Kumamoto earthquake sequence by using 200 sites broadband magnetotelluric data, and discuss its quantitative relationship to earthquake initiation, growth, and arrest processes. The ruptures that initiated along the outer edge of the low-resistivity fluid-rich zones (< 30 Ωm) tended to become large earthquakes, whereas those that initiated either distal to or within the fluid-rich zones did not. The ruptures were arrested by high-temperature (> 400 °C) fluid-rich zones, whereas shallower low-temperature (200–400 °C) fluid-rich zones either promoted or arrested the ruptures. These results suggest that the distribution of mid-crustal fluids contributes to the initiation, growth, and arrest of crustal earthquakes. The pre-failure pressure/temperature gradient (spatial difference) of the pore fluids may contribute to the rupture initiation, propagation, and arrest.
We conducted a broadband magnetotelluric (MT) survey along a north–south transect across Unzen graben, Japan. The MT survey line is located ~ 2 km west of the most recent lava dome and consisted of 27 stations along a 9-km profile. We estimated the 3-D resistivity structure and correlated it with the seismic reflection structure obtained by the same survey line as in the present study. The best-fit resistivity structure shows an upper resistive layer underlain by a moderately conductive layer. The resistive layer, which is interpreted as a cold groundwater zone, is cut by four faults marked by their relatively high conductivity. The underlying layer, which is interpreted as a hydrothermal-water-rich layer, also shows relatively conductive values near the faults. By assuming that the faults are imaged as relatively conductive zones, we infer the dip and depth extent of fracture zones around the faults. Beneath the Chijiwa Fault, which is the longest and most active fault of Unzen graben, the dominant conductor (C1) has a width of 2 km and extends down to below 4 km depth. C1 corresponds to a zone of strong seismic reflection and is located close to one of the pressure sources causing surface deformation. In this study, we interpret C1 as a network of fractures generated by the Chijiwa Fault to which magmatic volatiles are supplied from a deeper pressure source. Given that C1 extends to a greater depth and its resistivity is lower than other conductive zones, it is possible that earthquakes have occurred repeatedly on the Chijiwa Fault. In the center of the study area, we identify a vertically oriented body of high resistivity (R1) that corresponds to a zone of low seismic reflectivity. We interpret R1 as a cooled dyke complex that may have acted as a volcanic conduit.
A volcanic eruption transmits both seismic and infrasound signals. The seismo-acoustic power ratio is widely used to investigate the eruption behaviors and the source dynamics. It is often the case that seismic data during an eruption are significantly contaminated or even dominated by ground shaking due to infrasound (air-to-ground signals). To evaluate the contribution of infrasound-originated power in the seismic data, we need a response function of the seismic station to infrasound. It is rare to obtain a seismo-acoustic data set containing only infrasound signals, though it is ideal for calculating the response function. This study proposes a simple way to calculate the response function using seismo-acoustic data containing infrasound and independent seismic waves. The method requires data recorded at a single station and mainly uses the cross-correlation function between the infrasound data and the Hilbert transform of the seismic data. It is tested with data recorded by a station at Kirishima volcano, Japan, of which response function has been constrained. It is shown that the method calculates a proper response function even when the seismic data contain more significant seismic power (or noise) than the air-to-ground signals. The proposed method will be useful in monitoring and understanding eruption behaviors using seismo-acoustic observations.
We estimated the vent radius within Showa Crater of Sakurajima volcano from ejection velocity and flow rate of gas‐particle mixtures. The ejection velocity was calculated from video recordings, and the flow rate and volume from infrasound data. Based on the assumption that the vent shape does not change during an explosion, the vent radius was estimated from 201 impulsive Vulcanian eruptions at Showa Crater, yielding values of 6.4–42.3 m (median 23.8 m), which is comparable with the width of fresh lava capping the vent, as photographed from a helicopter. Long‐term changes in vent radius (i.e., over several months) show a relationship with magma accumulation within a reservoir 2–5 km beneath the crater. If the top of the conduit is assumed to be cylindrical, then the vertical extent of the gas‐rich zone is estimated to be 120 m, which may reflect the depth of gas accumulation and buildup of significant overpressure.
The Iwo-yama volcano of the Kirishima Volcanic Complex in Japan had a small phreatic eruption in April 2018, which newly formed multiple vents. The activity was recorded by two infrasound sensors and two monitoring cameras, which had been installed within 1 km of the vents. This study identified infrasonic signals from the multiple vents by a cross-correlation analysis between the two infrasound sensors. The analysis successfully revealed the signals from two main eruption craters and constrained the infrasound onsets at the individual vents in the two craters. We combined the infrasound results with the images from the cameras and reconstructed the sequence of the small phreatic eruption of Iwo-yama. At each of the two craters, the intense eruption, which was depicted by the evident infrasound signals, occurred several hours after the eruption onset. This study provides a sequence of the activities of the multiple vents in a phreatic eruption, which will be useful for understanding the phreatic eruption and hazard assessments.
From April to July 2021, West Crater at Iwo-Yama, Kirishima Volcanic Complex, Japan, was repeatedly filled with hydrothermal water and subsequently evacuated. The overall cycle lasted 14–70 h, and the course of a single cycle followed this sequence of phases: (i) steam effusion disappeared 20–40 min before hydrothermal water discharge; (ii) hydrothermal water discharge occurred, generating a hydrothermal water pool; (iii) steam effusion resumed and gradually increased; and (iv) drain-back (evacuation) of the hydrothermal water occurred 1–1.5 h before the onset of the next hydrothermal water discharge. We used multi-parametric observations (optical camera, thermometer, electric self-potential (SP) electrodes, seismometer, acoustic sensor, and tiltmeter) to investigate the cause of the cyclic hydrothermal water discharge. A change in SP data occurred approximately 2 h before the onset of hydrothermal water discharge. However, the change in SP was small when hydrothermal water discharge did not occur. The temporal change in SP is inferred to have been caused by groundwater flow through the region below West Crater, implying that groundwater flow was occurring 2 h before hydrothermal water discharge. The polarity of SP change suggests that groundwater flowed toward the region underlying the vents. Seismic signals in the frequency range of < 20 Hz decreased 15–45 min after the onset of change in SP. This seismic signal pattern is inferred to have been caused by bubble activity in boiling fluid. We interpret that the inflow of cold groundwater inhibited boiling activity in the conduit, which in turn caused the cessation of both steam effusion and seismic activity. SP data suggest that the inflow of cold groundwater gradually decreased before hydrothermal water discharge. Pressurization sufficient to force the water in the upper part of the conduit to ascend could have built up in the lower part of the conduit owing to a decrease in the input of groundwater into the upper part of the conduit and the continuing supply of steam bubbles and hot water. This increase in pressure finally led to hydrothermal water discharge at the surface. We suggest that the inflow of cold groundwater into the geyser conduit was the key control on the occurrence and cyclicity of hydrothermal water discharge in West Crater at Iwo-Yama. Graphical Abstract