Peter Saunders

Peter Saunders

Auto-generated profile, based on publicly available information

Peter Saunders

Measurement Standards Laboratory of New Zealand, Lower Hutt, NEW ZEALAND

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2021 in Metrologia
Verified
Journal Article
Closed access
PDF file
ATAndrew D W Todd
Andrew D W Todd
KAKlaus Anhalt
Klaus Anhalt
PBPieter Bloembergen
Pieter Bloembergen
BKBoris B Khlevnoy
Boris B Khlevnoy
DLDave H Lowe
Dave H Lowe
PSPeter Saunders
Peter Saunders
In July 2016 the Consultative Committee for Thermometry’s Non-Contact Thermometry Working Group formed a task group to compile a complete list of uncertainties for high-temperature fixed points, categorize them as well specified or not, and recommend areas of future research. We describe herein two paths to realizing T by indirect primary radiometry using high-temperature fixed-point blackbody cells: one in which published values for the metal–carbon eutectic material transition temperatures are used and the other where a set of cells has their transition temperatures determined directly. The uncertainty components that need to be considered for each path are given together with typically achievable values and how well those values are known. This work concentrates on Co–C, Pt–C and Re–C.

1 July 1992 in Deep Sea Research Part A. Oceanographic Research Papers
Verified
Journal Article
Closed access
PSPeter M. Saunders
Peter M. Saunders

9 June 2020 in Metrologia
Verified
Journal Article
Closed access
PDF file
PSPeter Saunders
Peter Saunders
Non-uniqueness is a fundamental limit to the reproducibility of a defined temperature scale. In this paper, the non-uniqueness of temperatures, T 90 , on the International Temperature Scale of 1990 (ITS-90) above the silver point is fully investigated for the first time. The non-uniqueness arises from three causes: inconsistency in extrapolation with the choice of the three allowable ITS-90 reference fixed points; a wavelength dependence of T 90 due to the difference between thermodynamic temperature, T , and T 90 at these reference fixed points; and a further wavelength dependence arising from the discrepancy between the value of the second radiation constant defined on ITS-90 and its value derived from fundamental constants. The non-uniqueness is quantified by deriving an exact expression for T − T 90 above the silver point and calculating the differences in this expression as a function of reference fixed point and wavelength. In the worst case, the non-uniqueness is about 100 mK, and T − T 90 is as much as 400 mK, at 3000 °C.

13 November 2018 in Metrologia
Verified
Journal Article
Closed access
PDF file
PSPeter Saunders
Peter Saunders
Uncertainty formulae are derived for propagating both correlated and uncorrelated components of uncertainty in spectral responsivity measurements directly through the Planck integrals for the radiation thermometry range of the international temperature scale of 1990 (ITS-90) and for absolute radiometry. These formulae are compared to those obtained using the Sakuma–Hattori equation as an approximation to the Planck integrals. It is shown that for typical spectral responsivity bandwidths, the differences are negligible, confirming that the Sakuma–Hattori approximation provides an excellent model for the basis of uncertainty propagation for radiation thermometry, resulting in simpler and more intuitive uncertainty equations.

28 February 2022 in Metrologia
Verified
Journal Article
Closed access
EMEllie Molloy
Ellie Molloy
PSP Saunders
P Saunders
AKAnnette Koo
Annette Koo
Goniometric measurements are essential for the determination of many optical quantities, and quantifying the effects of errors in the rotation axes on these quantities is a complex task. In this paper, we show how a measurement model for a four-axis goniometric system can be developed to allow the effects of alignment and rotation errors to be included in the uncertainty of the measurement. We use three different computational methods to propagate the uncertainties due to several error sources through the model to the rotation angles and then to the measurement of bidirectional reflectance and integrated diffuse reflectance, a task that would otherwise be intractable. While all three methods give the same result, the GTC Python package is the simplest and intrinsically provides a full uncertainty budget, including all correlations between measurement parameters. We then demonstrate how the development of a measurement model and the use of GTC has improved our understanding of the system. As a consequence, taking advantage of negative correlations between measurements in different geometries allows us to minimise the total uncertainty in integrated diffuse reflectance, lowering the standard uncertainty from 0.0029 to 0.0015.

30 July 2010 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
PSP. Saunders
P. Saunders
DWD. R. White
D. R. White