Ellie Molloy

Dr. Ellie Molloy

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2022 in Metrologia
Verified
Journal Article
Closed access
EMEllie Molloy
Ellie Molloy
PSP Saunders
P Saunders
AKAnnette Koo
Annette Koo
Goniometric measurements are essential for the determination of many optical quantities, and quantifying the effects of errors in the rotation axes on these quantities is a complex task. In this paper, we show how a measurement model for a four-axis goniometric system can be developed to allow the effects of alignment and rotation errors to be included in the uncertainty of the measurement. We use three different computational methods to propagate the uncertainties due to several error sources through the model to the rotation angles and then to the measurement of bidirectional reflectance and integrated diffuse reflectance, a task that would otherwise be intractable. While all three methods give the same result, the GTC Python package is the simplest and intrinsically provides a full uncertainty budget, including all correlations between measurement parameters. We then demonstrate how the development of a measurement model and the use of GTC has improved our understanding of the system. As a consequence, taking advantage of negative correlations between measurements in different geometries allows us to minimise the total uncertainty in integrated diffuse reflectance, lowering the standard uncertainty from 0.0029 to 0.0015.

21 April 2023 in Applied Optics
Verified
Journal Article
Closed access
NBNina Basic
Nina Basic
EMEllie Molloy
Ellie Molloy
AKAnnette Koo
Annette Koo
AFAlejandro Ferrero
Alejandro Ferrero
PGP. Santafé Gabarda
P. Santafé Gabarda
GOGael Obein
Gael Obein
In recent years, there has been a growing interest in the measurements of the bidirectional reflectance distribution function (BRDF) in industry and research and development. However, there is currently no dedicated key comparison to demonstrate the scale conformity. To date, scale conformity has been proved only for classical in-plane geometries, in comparisons between different national metrology institutes (NMIs) and designated institutes (DIs). This study aims at expanding that with nonclassical geometries, including, for the first time, to the best of our knowledge, two out-of-plane geometries. A total of four NMIs and two DIs participated in a scale comparison of the BRDF measurements of three achromatic samples at 550 nm in five measurement geometries. The realization of the scale of BRDF is a well-understood procedure, as explained in this paper, but the comparison of the measured values presents slight inconsistencies in some geometries, most likely due to the underestimation of measurement uncertainties. This underestimation was revealed and indirectly quantified using the Mandel–Paule method, which provides the interlaboratory uncertainty. The results from the presented comparison allow the present state of the BRDF scale realization to be evaluated, not only for classical in-plane geometries, but also for out-of-plane geometries.

21 February 2024 in Metrologia
Verified
Journal Article
Closed access
EMEllie Molloy
Ellie Molloy
AKAnnette Koo
Annette Koo
Measurements of both hemispherical reflectance and the bidirectional reflectance distribution function (BRDF) are of interest to a wide range of industries including computer graphics, remote sensing, lighting design, and cosmetics. The scale of directional reflectance is often realised at national metrology institutes using goniospectrophotometers, and by integrating BRDF measurements made over the hemisphere, the scale of hemispherical reflectance can also be realised. This paper describes the measurement model for BRDF and hemispherical reflectance using the MSL goniospectrophotometer, which uses rotation stages to adjust the angle of the sample. The measurement model is applied to measurements of a white Spectralon sample and a white ceramic tile to demonstrate the performance of the instrument. The relative standard uncertainty in the BRDF of a white Spectralon sample at 550 nm is less than 0.1% for in-plane measurements, while the relative standard uncertainty in the hemispherical reflectance of a white Spectralon sample at 560 nm is 0.27%.

24 July 2023
Verified
Thesis
Open access
PDF file
EMEllie Molloy
Ellie Molloy
We are continuously making judgements based on the appearance of objects around us. The appearance of an object depends on the way in which the object’s surface reflects, transmits, and absorbs the incident light. In recent years, there has been an increasing demand for traceable measurements of ‘appearance’ across various industries. While there has been extensive work carried out in national metrology institutes to develop traceable colour measurements, there are more and more requirements for multidimensional measurements, for example of the bidirectional reflectance and transmittance distribution functions (BRDF, BTDF). Measurements of these quantities require an instrument that allows changes to both the incident and detection angles, such as a goniospectrophotomer. Achieving traceability for measurements of the bidirectional scattering distribution function (BSDF, referring to either the BRDF or BTDF) and integrated BSDF requires an in-depth understanding of the instrument and all of the errors in the measurements. This thesis describes the measurement model developed for measurements of BSDF and integrated BSDF using the Measurement Standards Laboratory of New Zealand’s (MSL) goniospectrophotometer. This model considers all of the errors in the alignment of the instrument and the angles set by the instrument and propagates these through to the measured BSDF. A correction factor for the non-uniformity in the response of the detector is calculated and a new design for the detector is proposed to remove the need for this correction factor. The effect of the instrument signature is also considered. The measurement model is applied to various samples to demonstrate the insights that can be gained from a detailed model, which are then used to help lower the measurement uncertainty. The relative standard uncertainty in the BRDF of a white Spectralon sample at 550 nm is less than 0.1% for in-plane measurements, while the relative standard uncertainty in the diffuse reflectance (calculated from integrated BRDF measurements) of a white Spectralon sample at 560 nm is 0.25%. Finally, the model is applied to measurements of BTDF, which is integrated to calculate transmittance haze. The haze values measured using the goniospectrophotometer are compared with measurements of haze made according to the documentary standards using an integrating sphere. It is demonstrated that these two methods of measuring transmittance haze do not agree due to a conflict in the definition of transmittance haze. The BTDF measurements are used to simulate the integrating sphere haze and to calculate the sensitivity of the sphere measurements to various alignment errors.

1 August 2023 in Metrologia
Verified
Journal Article
Closed access
EMEllie Molloy
Ellie Molloy
AKAnnette Koo
Annette Koo
LGL Gevaux
L Gevaux
GOG Obein
G Obein
LYL Yang
L Yang
Accurate and traceable measurements of transmittance haze are required for quality control in various different industries, such as optoelectronics, automobiles, and agriculture. Transmittance haze is defined as the fraction of light transmitted through a material that deviates from the incident beam by more than 2.5∘. Various documentary standards specify the use of an integrating sphere with a prescribed geometry for the measurement of transmittance haze. This paper uses goniometric measurements of the bidirectional transmittance distribution function (BTDF) to calculate transmittance haze according to the definition and demonstrates that the sphere-based realisation of transmittance haze specified in the documentary standards does not agree with the definition, with the difference being up to 20% for some samples. The BTDF measurements are also used to simulate the integrating sphere haze, allowing the sensitivity of the sphere haze to errors in the integrating sphere geometry to be calculated.

7 May 2024 in Metrologia
Verified
Journal Article
Open access
JFJinglin Fu
Jinglin Fu
AFAlejandro Ferrero
Alejandro Ferrero
TQTatjana Quast
Tatjana Quast
MEMichael Esslinger
Michael Esslinger
PSPablo Santafé-Gabarda
Pablo Santafé-Gabarda
ASAlfred Schirmacher
Alfred Schirmacher
In recent years, a growing demand for the capability of performing accurate measurements of the bidirectional transmittance distribution function (BTDF) has been observed in industry, research and development, and aerospace applications. However, there exists no calibration and measurement capabilities-entry for BTDF in the database of the Bureau International des Poids et Mesures and to date no BTDF comparison has been conducted between different national metrology institutes (NMIs) or designated institutes (DIs). As a first step to a possible future key comparison and to test the existing capabilities of determining this measurand, two interlaboratory comparisons were performed. In comparison one, five samples of three different types of optical transmissive diffusers were measured by five NMIs and one DI. By specific sample choice, the focus for this study lay more on orientation-dependent scatter properties. In comparison two, where one NMI, one DI, one university, and three industrial partners investigated their measurement capabilities, the dependence on the orientation was not assessed, but two additional samples of the same material and different thickness were measured. Results of the two comparisons are presented, giving a good overview of existing experimental solutions, and showing specific sample-related problems to be solved for improved future BTDF measurements.