31 January 2005 in IEEE Transactions on Power Systems
This work presents the techniques derived for an efficient and accurate latency exploitation of electric networks using time-domain transients simulation software, such as the "electromagnetic transients program" (EMTP). Latency exploitation is related to the capability of numerically solving the differential equations governing the behavior of electric networks with different integration steps. With this approach, the limitations of a single fixed size integration step, as required by EMTP-type programs, can be overcome, resulting in a decreased number of numerical operations for a given total simulation time. Using a network partitioning and recombination technique, latency exploitation is achieved using noniterative solutions. Results are shown for networks consisting exclusively of lumped elements and networks with transmission lines and are compared with those obtained from conventional EMTP simulations.
11 December 2006 in IEEE Transactions on Circuits and Systems I: Regular Papers
Multirate simulation of electric networks exhibiting a wide variety of time constants decreases the simulation runtimes by exploiting the property of circuit latency. The fundamental idea is to use different integration steps for different network subsystems, according to the requirements of accuracy of each subsystem. Programs that exploit circuit latency are usually based on relaxation methods that require iterations among the different subsystems of the original networks. These methods lack the numerical robustness of direct implicit integration methods used in circuit simulators and are not adequate for real-time simulation due to their non-uniform solution times. This paper proposes circuit latency exploitation without iterations making use of the concept of interlinked Multi-Area Thevenin Equivalents (MATE). Results are presented showing the efficiency and accuracy of the method
16 April 2024 in IEEE Transactions on Electromagnetic Compatibility
Grounding system design ensures safety compliance for transmission lines under lightning conditions. In this article, the transient response of short concrete encased grounding electrodes is investigated, that is, a 2.5 m vertical rod and a 10 m horizontal electrode (HE) (counterpoise). Situations of first and subsequent lightning strokes applied to horizontal and vertical concrete encapsulated electrodes are analyzed. The effect of the frequency dependence of soil parameters is considered. Also, soils with low, medium, and high resistivities $(\text{300}{\bm{ }}$ to $\text{4000}{\bm{\ }}\Omega .m)$ are evaluated. Different lengths of concrete encasement are considered in order to verify situations with either partial or total encapsulation. For all these cases, the harmonic impedance (from 60 Hz to 4 MHz) is calculated, and the respective ground potential rise is derived for median lightning currents. The results obtained indicate that concrete encased electrodes produced reductions in the impulse impedance up to 30% for the HE and 44% for the vertical electrode. Moreover, for the evaluated situations, the percentage reduction on impulse impedance was only slightly affected by the increase in soil resistivity, which is also observed for soils modeled with constant parameters.
27 June 2024 in Electric Power Systems Research
1 September 2016 in Electric Power Systems Research
23 December 2021 in IEEE Latin America Transactions
This work evaluates the efficiency of installing surge arresters in only one or two phases concerning the lightning performance of transmission lines. The simulations were performed in the ATP software, taking as reference a Brazilian 138 kV transmission line, and considering the rigorous representation of the frequency-dependent behavior of the tower footing impedance. The electrical parameters of the soil were considered as either constants or frequency-dependent, in order to analyze the influence of this effect in partially protected lines. The results obtained have shown that the partial protection technique is highly efficient. Although it does not guarantee the protection of the unprotected phase(s), the probability of insulation breakdown is strongly decreased. It was also verified that the inclusion of the frequency-dependent effect in the soil parameters significantly reduces the backflashover rate estimates of the studied line when compared to the constant values situation.