Jie Tong

Jie Tong

Auto-generated profile, based on publicly available information

Jie Tong

China Electric Power Research Institute, Beijing 100192, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2023 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
KWKehe Wu
Kehe Wu
RCrui cheng
rui cheng
HXHuiyan Xu
Huiyan Xu
JTJie Tong
Jie Tong
As a novel network security scheme, the zero trust model can effectively improve the traditional role-based access control model in the public network by continuous trust evaluation and dynamic authorization. As a private network for collecting the health status data of the power equipment, the terminals in the power Internet of Things (IoT) have the characteristics of fixed and controllable hardware, software, and users, and the main network security threat of the power IoT comes from the risk of terminals being damaged or forged. Therefore, based on the analysis of the key connotation of the zero trust and the security characteristics of the power IoT, this paper proposes a novel zero trust model and framework to synthetically evaluate the security status of the power IoT based on the behaviour and characteristics of the terminals. The analysis based on the stochastic Petri net and simulation results show that the proposed model can effectively address network security problems and significantly improve the level of security protection of the power IoT.

1 December 2017
Verified
Conference Paper
Closed access
GZGuoDong Zhu
GuoDong Zhu
JTJie Tong
Jie Tong
DWDaWei Wang
DaWei Wang
JJJing Jin
Jing Jin
JHJun Hu
Jun Hu
WYWen-Yan Yin
Wen-Yan Yin
Electrical-thermal co-simulation based on finite element method and massively parallel scheme which can perform on a supercomputer is proposed. Accuracy of the in-house high-performance computing scheme is validated by comparing the simulated results with commercial software. Then, a high frequency microstrip filter in system in package is analyzed by the proposed scheme.

1 December 2018
Verified
Conference Paper
Closed access
LYLei Yuqing
Lei Yuqing
QLQi Liyan
Qi Liyan
LWLei Weiqing
Lei Weiqing
GKGuo Kunya
Guo Kunya
TJTong Jie
Tong Jie
OPLC is an important facility in the power fiber-to-the-home project, and it is an important means to achieve deep integration of power grid and communication network infrastructure. The OPLC temperature is closely related to the lifetime of the composite cable. The paper firstly analyzed important reasons for the temperature's varying with cable surface of an OPLC core, and proposed that the oxidation of an insulating material such as XLPE is caused by the thermal aging, electrical aging, and photo aging of composite cable material with high temperature. With these results, the paper raised a technology for OPLC on-line condition monitoring and its safe state assessment, which uses the distributed temperature and current sensors to extract the on-line state parameters of the composite cable, and uses the internal and external temperature characteristics to evaluate the safe operation state of the OPLC. These temperature characteristics of the OPLC composite cable were further verified in the aging test of the composite cable. The method proposed in this paper can help the operation and maintenance staff to master the operation status of OPLC, scientifically develop equipment maintenance plans, and ensure network security.