11 February 2021 in Physical Review Letters
We report the first measurement of sub-Doppler molecular response using a frequency comb by employing the comb as a probe in optical-optical double-resonance spectroscopy. We use a continuous wave pump and a comb probe to detect sub-Doppler transitions to the and bands of methane with center frequency accuracy. These measurements provide the first verification of the accuracy of theoretical predictions from highly vibrationally excited states, needed to model the high-temperature spectra of exoplanets. Transition frequencies to the band show good agreement with the TheoReTS line list.
27 October 2011 in Journal of the Optical Society of America B
Noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) based on a fiber-coupled electro-optic modulator (EOM) provides a compact and versatile experimental setup. It has, however, been limited by background signals originating from an imbalance of the phase modulated triplet created by a cross-coupling between the principal axes of the polarization maintaining fibers and the extraordinary axis of the EOM. Two strategies for reducing these background signals are investigated: (i) using an EOM with a titanium diffused waveguide, in which the balance of the triplet is controlled by active feedback, and (ii) using an EOM with a proton exchanged waveguide that does not support light propagation along the ordinary axis. It is shown that both approaches significantly reduce drifts and noise in the system. Using a cavity with a finesse of 5700, an absorption sensitivity of in of integration time (i.e., ) is demonstrated for Doppler-broadened detection, the lowest reported so far for Doppler-broadened NICE-OHMS. For sub- Doppler detection, a minimum detectable optical phase shift of in of integration time is obtained.
11 February 2021 in Physical Review A
Optical-optical double-resonance spectroscopy with a continuous wave pump and frequency comb probe allows measurement of sub-Doppler transitions to highly excited molecular states over a wide spectral range with high frequency accuracy. We report on assessment and characterization of sub-Doppler double-resonance transitions in methane measured using a 3.3- continuous wave optical parametric oscillator as a pump and a 1.67- frequency comb as a probe. The comb spectra were recorded using a Fourier transform spectrometer with comb-mode-limited resolution. With the pump tuned to nine different transitions in the fundamental band, we detected 36 ladder-type transitions to the overtone band region, and 18 V-type transitions to the overtone band. We describe in detail the experimental approach and the pump stabilization scheme, which currently limits the frequency accuracy of the measurement. We present the data analysis procedure used to extract the frequencies and intensities of the probe transitions for parallel and perpendicular relative pump-probe polarization. We compare the center frequencies and relative intensities of the ladder-type transitions to theoretical predictions from the TheoReTS and ExoMol line lists, demonstrating good agreement with TheoReTS.
6 April 2012 in Journal of the Optical Society of America B
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
4 November 2014 in Journal of the Optical Society of America B
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
2 February 2015 in Optics Letters
An optical parametric oscillator based Doppler-broadened (Db) noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS) system suitable for addressing fundamental vibrational transitions in the 3.2–3.9 μm mid-infrared (MIR) region has been realized. An Allan–Werle analysis provides a detection sensitivity of methane of with a 20 s integration time, which corresponds to 90 ppt of if detected at the strongest transition addressed at 40 Torr. This supersedes that of previous Db MIR NICE-OHMS demonstrations and suggests that the technique can be suitable for detection of both the environmentally important and isotopologues. It also opens up for detection of many other molecular species at ppt and sub-ppt concentration levels.