Isak Silander

Isak Silander

Auto-generated profile, based on publicly available information

Isak Silander

Department of Physics, Umeå University 1 , 901 87 Umeå

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2021 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
LRLucile Rutkowski
Lucile Rutkowski
ISIsak Silander
Isak Silander
AJAlexandra C. Johansson
Alexandra C. Johansson
VOVinicius Silva de Oliveira
Vinicius Silva de Oliveira
KLKevin K. Lehmann
Kevin K. Lehmann
We report the first measurement of sub-Doppler molecular response using a frequency comb by employing the comb as a probe in optical-optical double-resonance spectroscopy. We use a 3.3  μm continuous wave pump and a 1.67  μm comb probe to detect sub-Doppler transitions to the 2ν3 and 3ν3 bands of methane with ∼1.7  MHz center frequency accuracy. These measurements provide the first verification of the accuracy of theoretical predictions from highly vibrationally excited states, needed to model the high-temperature spectra of exoplanets. Transition frequencies to the 3ν3 band show good agreement with the TheoReTS line list.

27 October 2011 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
PDF file
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
ISIsak Silander
Isak Silander
OAOve Axner
Ove Axner
Noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) based on a fiber-coupled electro-optic modulator (EOM) provides a compact and versatile experimental setup. It has, however, been limited by background signals originating from an imbalance of the phase modulated triplet created by a cross-coupling between the principal axes of the polarization maintaining fibers and the extraordinary axis of the EOM. Two strategies for reducing these background signals are investigated: (i) using an EOM with a titanium diffused waveguide, in which the balance of the triplet is controlled by active feedback, and (ii) using an EOM with a proton exchanged waveguide that does not support light propagation along the ordinary axis. It is shown that both approaches significantly reduce drifts and noise in the system. Using a cavity with a finesse of 5700, an absorption sensitivity of 3.2×10−12 cm−1 in 1 min of integration time (i.e., 1.8×10−11 cm−1 Hz−1/2) is demonstrated for Doppler-broadened detection, the lowest reported so far for Doppler-broadened NICE-OHMS. For sub- Doppler detection, a minimum detectable optical phase shift of 1.3×10−12 cm−1 in 400 s of integration time is obtained.

11 February 2021 in Physical Review A
Verified
Journal Article
Open access
PDF file
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
LRLucile Rutkowski
Lucile Rutkowski
ISIsak Silander
Isak Silander
AJAlexandra C. Johansson
Alexandra C. Johansson
VOVinicius Silva de Oliveira
Vinicius Silva de Oliveira
KLKevin K. Lehmann
Kevin K. Lehmann
Optical-optical double-resonance spectroscopy with a continuous wave pump and frequency comb probe allows measurement of sub-Doppler transitions to highly excited molecular states over a wide spectral range with high frequency accuracy. We report on assessment and characterization of sub-Doppler double-resonance transitions in methane measured using a 3.3-μm continuous wave optical parametric oscillator as a pump and a 1.67-μm frequency comb as a probe. The comb spectra were recorded using a Fourier transform spectrometer with comb-mode-limited resolution. With the pump tuned to nine different transitions in the ν3 fundamental band, we detected 36 ladder-type transitions to the 3ν3 overtone band region, and 18 V-type transitions to the 2ν3 overtone band. We describe in detail the experimental approach and the pump stabilization scheme, which currently limits the frequency accuracy of the measurement. We present the data analysis procedure used to extract the frequencies and intensities of the probe transitions for parallel and perpendicular relative pump-probe polarization. We compare the center frequencies and relative intensities of the ladder-type transitions to theoretical predictions from the TheoReTS and ExoMol line lists, demonstrating good agreement with TheoReTS.

6 April 2012 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
PDF file
ISIsak Silander
Isak Silander
PEPatrick Ehlers
Patrick Ehlers
JWJunyang Wang
Junyang Wang
OAOve Axner
Ove Axner
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

4 November 2014 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
PDF file
PEPatrick Ehlers
Patrick Ehlers
AJAlexandra C. Johansson
Alexandra C. Johansson
ISIsak Silander
Isak Silander
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
OAOve Axner
Ove Axner
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

2 February 2015 in Optics Letters
Verified
Journal Article
Closed access
PDF file
ISIsak Silander
Isak Silander
THThomas Hausmaninger
Thomas Hausmaninger
WMWeiguang Ma
Weiguang Ma
FHFrans Harren
Frans Harren
OAOve Axner
Ove Axner
An optical parametric oscillator based Doppler-broadened (Db) noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS) system suitable for addressing fundamental vibrational transitions in the 3.2–3.9 μm mid-infrared (MIR) region has been realized. An Allan–Werle analysis provides a detection sensitivity of methane of 1.5×10−9  cm−1 with a 20 s integration time, which corresponds to 90 ppt of CH4 if detected at the strongest transition addressed at 40 Torr. This supersedes that of previous Db MIR NICE-OHMS demonstrations and suggests that the technique can be suitable for detection of both the environmentally important CH413 and CH3D isotopologues. It also opens up for detection of many other molecular species at ppt and sub-ppt concentration levels.