Lucile Rutkowski

Dr. Lucile Rutkowski

Institut de Physique de Rennes, Rennes, Bretagne, France
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2016 in Physical Review A
Verified
Journal Article
Closed access
PDF file
PMPiotr Maslowski
Piotr Maslowski
KLKevin F. Lee
Kevin F. Lee
AJAlexandra C. Johansson
Alexandra C. Johansson
AKAmir Khodabakhsh
Amir Khodabakhsh
GKGrzegorz Kowzan
Grzegorz Kowzan
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
We overcome the resolution limit of Fourier-transform spectrometry and measure instrumental line-shape-free broadband molecular spectra with lines narrower than the optical path-limited resolution. We do this by using an optical frequency comb and precisely matching the maximum delay range of the spectrometer to the comb line spacing to measure the intensities of the individual comb lines. This method allows measurements of undistorted high-resolution spectra with acquisition time and interferometer length reduced by orders of magnitude and with frequency scale accuracy given by the comb.

1 January 2018 in Journal of Quantitative Spectroscopy and Radiative Transfer
Verified
Journal Article
Open access
LRLucile Rutkowski
Lucile Rutkowski
PMPiotr Maslowski
Piotr Maslowski
AJAlexandra C. Johansson
Alexandra C. Johansson
AKAmir Khodabakhsh
Amir Khodabakhsh
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
Broadband precision spectroscopy is indispensable for providing high fidelity molecular parameters for spectroscopic databases. We have recently shown that mechanical Fourier transform spectrometers based on optical frequency combs can measure broadband high-resolution molecular spectra undistorted by the instrumental line shape (ILS) and with a highly precise frequency scale provided by the comb. The accurate measurement of the power of the comb modes interacting with the molecular sample was achieved by acquiring single-burst interferograms with nominal resolution matched to the comb mode spacing. Here we describe in detail the experimental and numerical steps needed to achieve sub-nominal resolution and retrieve ILS-free molecular spectra, i.e. with ILS-induced distortion below the noise level. We investigate the accuracy of the transition line centers retrieved by fitting to the absorption lines measured using this method. We verify the performance by measuring an ILS-free cavity-enhanced low-pressure spectrum of the 3ν1 + ν3 band of CO2 around 1575 nm with line widths narrower than the nominal resolution. We observe and quantify collisional narrowing of absorption line shape, for the first time with a comb-based spectroscopic technique. Thus retrieval of line shape parameters with accuracy not limited by the Voigt profile is now possible for entire absorption bands acquired simultaneously

24 April 2017 in Optics Letters
Verified
Journal Article
Open access
PDF file
GSGrzegorz Sobon
Grzegorz Sobon
TMTadeusz Martynkien
Tadeusz Martynkien
PMPawel Mergo
Pawel Mergo
LRLucile Rutkowski
Lucile Rutkowski
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
We demonstrate a broadband mid-infrared (MIR) frequency comb source based on difference frequency generation (DFG) in periodically poled lithium niobate crystal. MIR radiation is obtained via mixing of the output of a 125 MHz repetition rate Yb-doped fiber laser with Raman-shifted solitons generated from the same source in a highly nonlinear fiber. The resulting idler is tunable in the range of 2.7–4.2 μm, with average output power reaching 237 mW and pulses as short as 115 fs. The coherence of the MIR comb is confirmed by spectral interferometry and heterodyne beat measurements. Applicability of the developed DFG source for laser spectroscopy is demonstrated by measuring absorption spectrum of acetylene at 3.0–3.1 μm.

23 May 2016 in Optics Letters
Verified
Journal Article
Closed access
PDF file
AKAmir Khodabakhsh
Amir Khodabakhsh
VRVenkata Ramaiah-Badarla
Venkata Ramaiah-Badarla
LRLucile Rutkowski
Lucile Rutkowski
AJAlexandra C. Johansson
Alexandra C. Johansson
KLKevin F. Lee
Kevin F. Lee
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
We present a versatile mid-infrared frequency comb spectroscopy system based on a doubly resonant optical parametric oscillator tunable in the 3–5.4 μm range and two detection methods: a Fourier transform spectrometer (FTS) and a continuous-filtering Vernier spectrometer (CF-VS). Using the FTS with a multipass cell, we measure high precision broadband absorption spectra of CH4 at 3.3 μm and NO at 5.25 μm, the latter for the first time with comb spectroscopy, and we detect atmospheric species (CH4, CO, CO2, and H2O) in air in the signal and idler ranges. Multiline fitting yields minimum detectable concentrations of 10–20 ppb Hz−1/2 for CH4, NO, and CO. For the first time in the mid-infrared, we perform CF-VS using an enhancement cavity, a grating, and a single detector, and we measure the absorption spectrum of CH4 and H2O in ambient air at ∼3.3 μm, reaching a 40 ppb concentration detection limit for CH4 in 2 ms.

11 February 2021 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
LRLucile Rutkowski
Lucile Rutkowski
ISIsak Silander
Isak Silander
AJAlexandra C. Johansson
Alexandra C. Johansson
VOVinicius Silva de Oliveira
Vinicius Silva de Oliveira
KLKevin K. Lehmann
Kevin K. Lehmann
We report the first measurement of sub-Doppler molecular response using a frequency comb by employing the comb as a probe in optical-optical double-resonance spectroscopy. We use a 3.3  μm continuous wave pump and a 1.67  μm comb probe to detect sub-Doppler transitions to the 2ν3 and 3ν3 bands of methane with ∼1.7  MHz center frequency accuracy. These measurements provide the first verification of the accuracy of theoretical predictions from highly vibrationally excited states, needed to model the high-temperature spectra of exoplanets. Transition frequencies to the 3ν3 band show good agreement with the TheoReTS line list.

29 August 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
LRLucile Rutkowski
Lucile Rutkowski
AJAlexandra C. Johansson
Alexandra C. Johansson
GZGang Zhao
Gang Zhao
THThomas Hausmaninger
Thomas Hausmaninger
AKAmir Khodabakhsh
Amir Khodabakhsh
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
Optical cavities provide high sensitivity to dispersion since their resonance frequencies depend on the index of refraction. We present a direct, broadband, and accurate measurement of the modes of a high finesse cavity using an optical frequency comb and a mechanical Fourier transform spectrometer with a kHz-level resolution. We characterize 16000 longitudinal cavity modes spanning 16 THz of bandwidth in terms of center frequency, linewidth, and amplitude. Using the center frequencies we retrieve the group delay dispersion of the cavity mirror coatings and pure N2 with 0.1 fs2 precision and 1 fs2 accuracy, as well as the refractivity of the 3ν1 + ν3 absorption band of CO2 with 5 × 10−12 precision. This opens up for broadband refractive index metrology and calibration-free spectroscopy of entire molecular bands.