19 August 2020 in IEEE Transactions on Antennas and Propagation
This paper presents a novel method to design a linear-tocircular polarization converter (LCPC) by using a hybrid array structure, which is composed of meander-lines and the split ring resonators (SRRs). The LCPC can respond to both the E-field and Hfield for the incident wave. When the meander-line and the SRR are placed along two orthogonal directions, the composed unit cell would have different electromagnetic response characteristics in the two orthogonal directions. Using this method, two LCPCs working in frequency bands of 6-18 GHz and 2-6 GHz, are designed respectively. The simulated results show that, for the LCPC working in 6-18 GHz, the axial ratio (AR) is lower than 3 dB in 6.8-17.32 GHz with a maximum insertion loss (IL) of 1.25 dB. When the angle of incident wave is less than 45°, the 3 dB AR bandwidth is 7.87 GHz. For the LCPC working in 2-6 GHz, the AR of entire frequency band is all lower than 3 dB and the maximum IL is 0.82 dB when the incident angle increases to 15°. Even at incident angle of 45°, the bandwidth with the function of polarization conversion is 3.5 GHz. Experiments on the LCPC (6-18 GHz) are carried out, and the measured results are in agreement with the simulated ones, which proves that the LCPCs design method proposed in this paper is effective and reliable.
20 December 2016 in IET Microwaves, Antennas & Propagation
A novel short‐ and open‐stub loaded spiral resonator (SOSL‐SR) is presented and analysed by the odd‐ and even‐mode method to obtain three controllable resonant modes. Therefore, a triple‐mode bandpass filter (BPF) has been designed with good frequency selectivity based on the proposed SOSL‐SR. Then, by dividing these three resonant modes into two passbands or stopbands, a dual‐band BPF and a dual‐band bandstop filter using the proposed SOSL‐SR have been demonstrated. Because of the spiral structure, the sizes of these three designed microstrip filters are reduced significantly. Good agreement between simulated and measured results validates the design concept.
6 September 2022 in Applied Physics A
13 January 2021 in Applied Physics A
1 October 2026 in IEEE Transactions on Industrial Electronics
In dynamic wireless power transfer systems, long segmented transmitter couplers facilitate simplified control and mitigate voltage fluctuations. However, dynamic capacitive power transfer (CPT) systems typically operate in the MHz range, where the high-frequency excitation wavelength is comparable to the dimensions of long segmented transmitter plates. This induces significant transmission line effects (TLE) in the system couplers, resulting severe electric-field inhomogeneity and even near-zero-field regions. These issues severely constrain the system’s power transfer capacity and stability. This article develops a mathematical model for dynamic CPT systems accounting for the TLE in long segmented transmitter plates, and analyzes the electric-field distribution around transmitter plates as well as the receiver output characteristics. It also proposes an open-loop output voltage fluctuation suppression method based on switchable terminal reactance, along with a corresponding terminal reactance parameters optimization method and switching strategy. Integrated with the transmitter’s DC–DC converter, it enables closed-loop control of output voltage. An experimental prototype was built with an operating frequency of 6.78 MHz, 10 m-long transmitter plates, and a system power of 30 W. Experimental results demonstrate distinct near-zero-power operation intervals in the output voltage without terminal reactance, with the voltage fluctuation rate approaching nearly 100%. Adopting the proposed method reduces the open-loop output voltage fluctuation rate to 30.1%, and implementing closed-loop control further decreases it to within 5%. The fluctuation trends and amplitudes of the system output voltage before and after using the proposed method are consistent with theoretical values, verifying that the proposed method realizes stable constant-voltage output across all segments of dynamic CPT systems.