19 October 2016 in IEEE/ASME Transactions on Mechatronics
The training for both translation and rotation of the hand is desirable for patients with impairments. This paper focuses on the design and control of a 7-degree-of-freedom cable-driven arm exoskeleton (CAREX-7), used for dexterous motion (including translation and rotation) training or assistance of the whole-arm. The CAREX-7 includes an additional wrist module compared with CAREX, and eight cables are routed through the exoskeleton cuffs to drive the whole-arm motion. Based on the “assist-as-needed” paradigm, a novel wrench-field controller was designed to regulate a needed wrench (force and torque) on the hand for assisting its dexterous manipulation. Healthy subjects participated in path-tracking experiments while wearing CAREX-7. The experimental results show that the CAREX-7 with the new wrench-field controller can help the subjects to follow the path more closely, and this demonstrates the effectiveness of the device. The current design of CAREX-7 is unique and offers significant improvements and new functionality over the existing CAREX. The novel features are the following: 1) CAREX-7 is an exoskeleton for the full human arm, including shoulder, elbow, and the wrist, with new design issues; and 2) controller of CAREX-7 builds on a screw-theoretic approach and assists both translation and rotation of the hand, allowing for dexterous hand reorientation, which is required in everyday tasks.
5 June 2014 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
In recent years, the authors have proposed lightweight exoskeleton designs for upper arm rehabilitation using multi-stage cable-driven parallel mechanism. Previously, the authors have demonstrated via experiments that it is possible to apply “assist-as-needed” forces in all directions at the end-effector with such an exoskeleton acting on an anthropomorphic machine arm. A human-exoskeleton interface was also presented to show the feasibility of CAREX on human subjects. The goals of this paper are to 1) further address issues when CAREX is mounted on human subjects, e.g., generation of continuous cable tension trajectories 2) demonstrate the feasibility and effectiveness of CAREX on movement training of healthy human subjects and a stroke patient. In this research, CAREX is rigidly attached to an arm orthosis worn by human subjects. The cable routing points are optimized to achieve a relatively large “tensioned” static workspace. A new cable tension planner based on quadratic programming is used to generate continuous cable tension trajectory for smooth motion. Experiments were carried out on eight healthy subjects. The experimental results show that CAREX can help the subjects move closer to a prescribed circular path using the force fields generated by the exoskeleton. The subjects also adapt to the path shortly after training. CAREX was also evaluated on a stroke patient to test the feasibility of its use on patients with neural impairment. The results show that the patient was able to move closer to a prescribed straight line path with the “assist-as-needed” force field.
14 July 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Individuals with chronic hemiparesis post-stroke exhibit gait impairments that require functional rehabilitation through training. Exoskeletal robotic assistive devices can provide a user with continuous assistance but impose movement restrictions. There are currently devices that allow unrestricted movement but provide assistance only intermittently at specific points of the gait cycle. Our design, a cable-driven active leg exoskeleton (C-ALEX), allows the user both unrestricted movement and continuous force assistance throughout the gait cycle to assist the user in new walking patterns. In this study, we assessed the ability of C-ALEX to induce a change in the walking patterns of ten post-stroke participants using a singlesession training protocol. The ability of C-ALEX to accurately provide forces and torques in the desired directions was also evaluated to compare its design performance to traditional rigidlink designs. Participants were able to reach 91% ± 12% of their target step length and 89% ± 13 % of their target step height. The achieved step parameters differed significantly from participant baselines (p < 0.05). To quantify the performance, the forces in each cable’s out of the plane movements were evaluated relative to the in-plane desired cable tension magnitudes. This corresponded to an error of under 2Nm in the desired controlled joint torques. This error magnitude is low compared to the system command torques and typical adult biological torques during walking (2-4%) [1]. These results point to the utility of using non-restrictive cable-driven architectures in gait retraining, in which future focus can be on rehabilitating gait pathologies seen in stroke survivors.
13 March 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Exoskeletons for gait training commonly use a rigid-linked “skeleton” which makes them heavy and bulky. Cable-driven exoskeletons eliminate the rigid-linked skeleton, providing a lighter and transparent design. Current cable-driven exoskeletons are aimed only at gait assistance by provide short bursts of forces to the leg during walking. It has not yet been shown if these designs are suitable for gait retraining where rehabilitative forces need to be continuously applied to the leg in response to errors from a desired movement. The goal of this study is to investigate if a cable-driven leg exoskeleton can retrain the gait of human users. Nine healthy subjects were trained by a cable-driven leg exoskeleton to walk in a new gait pattern with 30% increase in step height from their natural gait. After 40 minutes of training, the gait of the subjects became significantly closer to the target gait than before the training. In three different post-training sessions, the step height of the subjects increased by 22%, 29% and 31% on an average. In a fourth post-training session when the subjects were instructed to ignore the training and walk naturally, the step height remained increased by 11%. These results confirm the potential of cable-driven designs in gait training applications.