Rand Hidayah

Rand Hidayah

Auto-generated profile, based on publicly available information

Rand Hidayah

Columbia University, New York, New York, United States

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
RHRand Hidayah
Rand Hidayah
LBLauri Bishop
Lauri Bishop
XJXin Jin
Xin Jin
SCSiddharth Chamarthy
Siddharth Chamarthy
JSJoel Stein
Joel Stein
SASunil K. Agrawal
Sunil K. Agrawal
Individuals with chronic hemiparesis post-stroke exhibit gait impairments that require functional rehabilitation through training. Exoskeletal robotic assistive devices can provide a user with continuous assistance but impose movement restrictions. There are currently devices that allow unrestricted movement but provide assistance only intermittently at specific points of the gait cycle. Our design, a cable-driven active leg exoskeleton (C-ALEX), allows the user both unrestricted movement and continuous force assistance throughout the gait cycle to assist the user in new walking patterns. In this study, we assessed the ability of C-ALEX to induce a change in the walking patterns of ten post-stroke participants using a singlesession training protocol. The ability of C-ALEX to accurately provide forces and torques in the desired directions was also evaluated to compare its design performance to traditional rigidlink designs. Participants were able to reach 91% ± 12% of their target step length and 89% ± 13 % of their target step height. The achieved step parameters differed significantly from participant baselines (p < 0.05). To quantify the performance, the forces in each cable’s out of the plane movements were evaluated relative to the in-plane desired cable tension magnitudes. This corresponded to an error of under 2Nm in the desired controlled joint torques. This error magnitude is low compared to the system command torques and typical adult biological torques during walking (2-4%) [1]. These results point to the utility of using non-restrictive cable-driven architectures in gait retraining, in which future focus can be on rehabilitating gait pathologies seen in stroke survivors.

8 June 2021 in Wearable Technologies
Verified
Journal Article
Open access
PDF file
RHRand Hidayah
Rand Hidayah
DSDongbao Sui
Dongbao Sui
KWKennedi A. Wade
Kennedi A. Wade
BCBiing-Chwen Chang
Biing-Chwen Chang
SASunil K. Agrawal
Sunil K. Agrawal
Passive wearable exoskeletons are desirable as they can provide assistance during user movements while still maintaining a simple and low-profile design. These can be useful in industrial tasks where an ergonomic device could aid in load lifting without inconveniencing them and reducing fatigue and stress in the lower limbs. The SpringExo is a coil-spring design that aids in knee extension. In this paper, we describe the muscle activation of the knee flexors and extensors from seven healthy participants during repeated squats. The outcome measures are the timings of the key events during squat, flexion angle, muscle activation of rectus femoris and bicep femoris, and foot pressure characteristics of the participants. These outcome measures assess the possible effects of the device during lifting operations where reduced effort in the muscles is desired during ascent phase of the squat, without changing the knee and foot kinematics. The results show that the SpringExo significantly decreased rectus femoris activation during ascent (−2%) without significantly affecting either the bicep femoris or rectus femoris muscle activations in descent. This implies that the user could perform a descent without added effort and ascent with reduced effort. The exoskeleton showed other effects on the biomechanics of the user, increasing average squat time (+0.02 s) and maximum squat time (+0.1 s), and decreasing average knee flexion angle (−4°). The exoskeleton has no effect on foot loading or placement, that is, the user did not have to revise their stance while using the device.

22 July 2019 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
RHRand Hidayah
Rand Hidayah
SCSiddharth Chamarthy
Siddharth Chamarthy
ASAvni Shah
Avni Shah
MFMatthew Fitzgerald-Maguire
Matthew Fitzgerald-Maguire
SASunil K. Agrawal
Sunil K. Agrawal
Visual and force feedback are common elements in rehabilitation robotics, but visual feedback is difficult to provide in over-ground mobile exoskeleton systems. This letter aims to provide a method to integrate visual feedback using an augmented reality HoloLens headset with our mobile C-ALEX system. A preliminary study was carried out to assess the effects of providing force-only (Haptic), force and visual (HoloHapt) or visual (Visual) feedback to three independent groups, each containing eight participants. The groups showed an increase in normalized step height, nSH (HoloHapt: 1.10 $\pm$ 0.13, Haptic: 1.03 $\pm$ 0.23 Visual: 1.61 $\pm$ 0.52) and decreased normalized trajectory tracking error, TE (HoloHapt: 42.8% $\pm$ 23.4%, Haptic: 47.6% $\pm$ 18.4%, Visual: 114 .2 % $\pm$ 60.0 % ). Visual nSH differed significantly from HoloHapt and Haptic nSH ( $p< 0.005$ ). Lap-wise normalized tracking error differed significantly ( $p < 0.005$ ) within participants. The results show the feasibility of and differences between each form of feedback for overground gait training. This information is useful for future studies targeted at patients with gait impairments.

17 August 2021
Verified
Conference Paper
Closed access
PDF file
JHJiaxu Huang
Jiaxu Huang
RHRand Hidayah
Rand Hidayah
SASunil K. Agrawal
Sunil K. Agrawal
JDJorge A. Diez
Jorge A. Diez
NGNicolas Garcia-Aracil
Nicolas Garcia-Aracil
In this paper, a customized optical force sensor is developed for an application with a cable-driven leg exoskeleton. Sensors are vital components of cable-driven, exoskeletal robotic systems, which require real-time and accurate measurement of cable tensions. While these systems’ accuracy is a consideration, the added weight, volume, and complexity of the system must is an essential part of widespread adoption for wearable applications. These sensors can also be costly, which is undesirable. An optical force sensor has the advantages of being lightweight, lower in manufacturing cost, and easy to incorporate within the exoskeleton architecture. We designed a sensor to accommodate the expected force profiles and magnitudes during gait while wearing the Cable-Driven Active Leg Exoskeleton (C-ALEX) during a walking task. We carried out four different calibration tests with dynamic loading of the sensors from 10N to 40N. Once a sensor calibration was established, the optical sensor’s performance was compared to a traditional load cell in validation tests. Both components were used in an assist-as-needed force controller in a walking task with a user, with the optical force sensor incorporated into the C-ALEX exoskeleton arms. Comparing the sensor responses to the command tension forces, the results show a root-mean-square error (RMSE) of 0.9595N ± 0.5360N.