14 July 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Individuals with chronic hemiparesis post-stroke exhibit gait impairments that require functional rehabilitation through training. Exoskeletal robotic assistive devices can provide a user with continuous assistance but impose movement restrictions. There are currently devices that allow unrestricted movement but provide assistance only intermittently at specific points of the gait cycle. Our design, a cable-driven active leg exoskeleton (C-ALEX), allows the user both unrestricted movement and continuous force assistance throughout the gait cycle to assist the user in new walking patterns. In this study, we assessed the ability of C-ALEX to induce a change in the walking patterns of ten post-stroke participants using a singlesession training protocol. The ability of C-ALEX to accurately provide forces and torques in the desired directions was also evaluated to compare its design performance to traditional rigidlink designs. Participants were able to reach 91% ± 12% of their target step length and 89% ± 13 % of their target step height. The achieved step parameters differed significantly from participant baselines (p < 0.05). To quantify the performance, the forces in each cable’s out of the plane movements were evaluated relative to the in-plane desired cable tension magnitudes. This corresponded to an error of under 2Nm in the desired controlled joint torques. This error magnitude is low compared to the system command torques and typical adult biological torques during walking (2-4%) [1]. These results point to the utility of using non-restrictive cable-driven architectures in gait retraining, in which future focus can be on rehabilitating gait pathologies seen in stroke survivors.
8 June 2021 in Wearable Technologies
Passive wearable exoskeletons are desirable as they can provide assistance during user movements while still maintaining a simple and low-profile design. These can be useful in industrial tasks where an ergonomic device could aid in load lifting without inconveniencing them and reducing fatigue and stress in the lower limbs. The SpringExo is a coil-spring design that aids in knee extension. In this paper, we describe the muscle activation of the knee flexors and extensors from seven healthy participants during repeated squats. The outcome measures are the timings of the key events during squat, flexion angle, muscle activation of rectus femoris and bicep femoris, and foot pressure characteristics of the participants. These outcome measures assess the possible effects of the device during lifting operations where reduced effort in the muscles is desired during ascent phase of the squat, without changing the knee and foot kinematics. The results show that the SpringExo significantly decreased rectus femoris activation during ascent (−2%) without significantly affecting either the bicep femoris or rectus femoris muscle activations in descent. This implies that the user could perform a descent without added effort and ascent with reduced effort. The exoskeleton showed other effects on the biomechanics of the user, increasing average squat time (+0.02 s) and maximum squat time (+0.1 s), and decreasing average knee flexion angle (−4°). The exoskeleton has no effect on foot loading or placement, that is, the user did not have to revise their stance while using the device.
22 July 2019 in IEEE Robotics and Automation Letters
Visual and force feedback are common elements in rehabilitation robotics, but visual feedback is difficult to provide in over-ground mobile exoskeleton systems. This letter aims to provide a method to integrate visual feedback using an augmented reality HoloLens headset with our mobile C-ALEX system. A preliminary study was carried out to assess the effects of providing force-only (Haptic), force and visual (HoloHapt) or visual (Visual) feedback to three independent groups, each containing eight participants. The groups showed an increase in normalized step height, nSH (HoloHapt: 1.10 $\pm$ 0.13, Haptic: 1.03 $\pm$ 0.23 Visual: 1.61 $\pm$ 0.52) and decreased normalized trajectory tracking error, TE (HoloHapt: 42.8% $\pm$ 23.4%, Haptic: 47.6% $\pm$ 18.4%, Visual: 114 .2 % $\pm$ 60.0 % ). Visual nSH differed significantly from HoloHapt and Haptic nSH ( $p< 0.005$ ). Lap-wise normalized tracking error differed significantly ( $p < 0.005$ ) within participants. The results show the feasibility of and differences between each form of feedback for overground gait training. This information is useful for future studies targeted at patients with gait impairments.