Simon Moser

Simon Moser

Auto-generated profile, based on publicly available information

Simon Moser

Medical University of Innsbruck

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2024 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
ASAna S. Sotirova
Ana S. Sotirova
BSBangshan Sun
Bangshan Sun
JLJamie D. Leppard
Jamie D. Leppard
AWAndong Wang
Andong Wang
MWMohan Wang
Mohan Wang
CBChristopher J. Ballance
Christopher J. Ballance
Individual optical addressing in chains of trapped atomic ions requires the generation of many small, closely spaced beams with low cross-talk. Furthermore, implementing parallel operations necessitates phase, frequency, and amplitude control of each individual beam. Here, we present a scalable method for achieving all of these capabilities using a high-performance integrated photonic chip coupled to a network of optical fibre components. The chip design results in very low cross-talk between neighbouring channels even at the micrometre-scale spacing by implementing a very high refractive index contrast between the channel core and cladding. Furthermore, the photonic chip manufacturing procedure is highly flexible, allowing for the creation of devices with an arbitrary number of channels as well as non-uniform channel spacing at the chip output. We present the system used to integrate the chip within our ion trap apparatus and characterise the performance of the full individual addressing setup using a single trapped ion as a light-field sensor. Our measurements showed intensity cross-talk below ~10–3 across the chip, with minimum observed cross-talk as low as ~10–5.

16 March 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
MLMia Kvåle Løvmo
Mia Kvåle Løvmo
SDShiyu Deng
Shiyu Deng
SMSimon Moser
Simon Moser
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
WDWolfgang Drexler
Wolfgang Drexler
MRMonika Ritsch-Marte
Monika Ritsch-Marte
Organoid and spheroid technology provide valuable insights into developmental biology and oncology. Optical coherence tomography (OCT) is a label-free technique that has emerged as an excellent tool for monitoring the structure and function of these samples. However, mature organoids are often too opaque for OCT. Access to multi-angle views is highly desirable to overcome this limitation, preferably with non-contact sample handling. To fulfil these requirements, we present an ultrasound-induced reorientation method for multi-angle-OCT, which employs a 3D-printed acoustic trap inserted into an OCT imaging system, to levitate and reorient zebrafish larvae and tumor spheroids in a controlled and reproducible manner. A model-based algorithm was developed for the physically consistent fusion of multi-angle data from a priori unknown angles. We demonstrate enhanced penetration depth in the joint 3D-recovery of reflectivity, attenuation, refractive index, and position registration for zebrafish larvae, creating an enabling tool for future applications in volumetric imaging.

24 April 2025 in Optica
Verified
Journal Article
Open access
SMSimon Moser
Simon Moser
MLMia Kvåle Løvmo
Mia Kvåle Løvmo
FSFranziska Strasser
Franziska Strasser
JHJudith Hagenbuchner
Judith Hagenbuchner
MAMichael J. Ausserlechner
Michael J. Ausserlechner
MRMonika Ritsch-Marte
Monika Ritsch-Marte
Optical diffraction tomography (ODT) has emerged as a powerful tool for imaging biological cells in a non-invasive and label-free manner. However, conventional approaches using ODT by varying the illumination are plagued by the missing cone problem, which introduces ambiguity and deteriorates the axial resolution in the reconstruction. Although utilizing object rotation has the potential to yield an isotropic resolution, experimental control or prior retrieval of the rotational parameters is challenging. In this work, we demonstrate the ODT of multiple-scattering samples undergoing variable rotational motion, unlocking the potential for isotropic resolution in non-contact systems. We introduce a comprehensive reconstruction method to jointly retrieve both the sample and the rotational motion in 3D. An interferometric setup enables the recording of amplitude and phase data while the object is rotated in a non-contact manner around one or more chosen axes in an acoustofluidic device. We evaluate the tomographic reconstruction performance of the method for clusters of micro-beads and highlight its suitability for biomedical applications beyond single cells, demonstrating high-resolution reconstruction of dense cancer spheroids containing more than 100 cells.

4 June 2025 in Optics Express
Verified
Journal Article
Open access
SKSyed Muhammad Kazim
Syed Muhammad Kazim
FSFranziska Strasser
Franziska Strasser
MLMia Kvåle Løvmo
Mia Kvåle Løvmo
ANAndrii Nehrych
Andrii Nehrych
SMSimon Moser
Simon Moser
MRMonika Ritsch-Marte
Monika Ritsch-Marte
We demonstrate coded wavefront sensing (Coded WFS) for video-rate quantitative phase imaging and 3D refractive index (RI) tomography of biological specimens. To evaluate the accuracy, we implement an experimental setup that supports measurements of specimens with Coded WFS as well as with digital holographic microscopy (DHM) under identical conditions, enabling direct comparison. We image a static 3D phantom fabricated via additive manufacturing and a rotating HEK293 cell in an acoustofluidic chamber. Our results demonstrate good agreement between the two methods, with the advantage that, in contrast to DHM, Coded WFS enables simple integration with standard microscopes. Furthermore, we apply a standard tomographic reconstruction algorithm to the HEK293 cell data for comparison, which demonstrates the potential of Coded WFS in tomography.

4 March 2025 in Biomedical Optics Express
Verified
Journal Article
Open access
JMJulian G. Maloberti
Julian G. Maloberti
LVLukas Velas
Lukas Velas
SMSimon Moser
Simon Moser
AGAnna Gaugutz
Anna Gaugutz
MBMarina Bishara
Marina Bishara
AJAlexander Jesacher
Alexander Jesacher
The advent of single molecule localization microscopy (SMLM) has transformed our capacity to investigate biological structures at the nanoscale. While the research focus has long been on improving localization precision, systematic errors caused by optical aberrations are often overlooked. In the case of 3D SMLM, such errors have the potential to significantly impair the quality of the resulting images. In this paper, we present an imaging and data processing approach that jointly estimates both, molecule positions and optical aberrations in SMLM. Therefore, the method minimizes systematic errors in SMLM reconstructions without the necessity of additional experimental calibration steps, such as the recording of fluorescent bead z-stacks. We investigate the reliability of this approach, especially in situations where the joint retrieval can be expected to be ill-posed, i.e., whenever the sample is "flat" and provides little diversity among the captured single molecule images. To enhance the reliability of the inverse problem solution, we suggest utilizing small SMLM data sets acquired at one or more slightly defocused "auxiliary" planes. We investigate the effectiveness of our approach through numerical simulations and imaging experiments of a calibration probe and nuclear pore complexes. Our method is simple and integrates seamlessly into existing SMLM setups without necessitating modifications or added complexity to the system.

2 December 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
SMSimon Moser
Simon Moser
MLMia Kvale Lovmo
Mia Kvale Lovmo
FSFranziska Strasser
Franziska Strasser
JHJudith Hagenbuchner
Judith Hagenbuchner
MAMichael Ausserlechner
Michael Ausserlechner
MRMonika Ritsch-Marte
Monika Ritsch-Marte
Optical Diffraction Tomography (ODT) has emerged as a powerful tool for imaging biological cells in a non-invasive and label-free manner. However, conventional approaches using ODT by varying the illumination are plagued by the missing cone problem, which introduces ambiguity and deteriorates the axial resolution in the reconstruction. Although utilizing object rotation has the potential to yield isotropic resolution, experimental control or prior retrieval of the rotational parameters is challenging. In this work, we demonstrate ODT of multiple-scattering samples undergoing variable rotational motion, unlocking the potential for isotropic resolution in non-contact systems. We introduce a comprehensive reconstruction method to jointly retrieve both sample and rotational motion in 3D. An interferometric setup enables the recording of amplitude and phase data while the object is rotated in a non-contact manner around one or more chosen axes in an acoustofluidic device. We evaluate the tomographic reconstruction performance of the method for clusters of micro-beads and highlight its suitability for biomedical application beyond single cells, demonstrating high-resolution reconstruction of dense cancer spheroids containing more than 100 cells.