Mia Kvåle Løvmo

Mia Kvåle Løvmo

Auto-generated profile, based on publicly available information

Mia Kvåle Løvmo

Medical University of Innsbruck

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
MLMia Kvåle Løvmo
Mia Kvåle Løvmo
SDShiyu Deng
Shiyu Deng
SMSimon Moser
Simon Moser
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
WDWolfgang Drexler
Wolfgang Drexler
MRMonika Ritsch-Marte
Monika Ritsch-Marte
Organoid and spheroid technology provide valuable insights into developmental biology and oncology. Optical coherence tomography (OCT) is a label-free technique that has emerged as an excellent tool for monitoring the structure and function of these samples. However, mature organoids are often too opaque for OCT. Access to multi-angle views is highly desirable to overcome this limitation, preferably with non-contact sample handling. To fulfil these requirements, we present an ultrasound-induced reorientation method for multi-angle-OCT, which employs a 3D-printed acoustic trap inserted into an OCT imaging system, to levitate and reorient zebrafish larvae and tumor spheroids in a controlled and reproducible manner. A model-based algorithm was developed for the physically consistent fusion of multi-angle data from a priori unknown angles. We demonstrate enhanced penetration depth in the joint 3D-recovery of reflectivity, attenuation, refractive index, and position registration for zebrafish larvae, creating an enabling tool for future applications in volumetric imaging.

26 February 2021 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
MLMia Kvåle Løvmo
Mia Kvåle Løvmo
BPBenedikt Pressl
Benedikt Pressl
GTGregor Thalhammer
Gregor Thalhammer
MRMonika Ritsch-Marte
Monika Ritsch-Marte
Optical and 3D acoustic trapping are combined in a microfluidic ‘sono-optical’ device to control the orientation or to induce sustained rotation of sub-millimeter-sized biological samples, such as micro-organisms, pollen grains or cell-clusters.

6 July 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MLMia Kvale Lovmo
Mia Kvale Lovmo
PYPetros Tesfamichael Yemane
Petros Tesfamichael Yemane
ABAstrid Bjorkoy
Astrid Bjorkoy
RHRune Hansen
Rune Hansen
RCRobin O. Cleveland
Robin O. Cleveland
CDCatharina De Lange Davies
Catharina De Lange Davies
Penetration of nanoscale therapeutic agents into the extracellular matrix (ECM) of a tumor is a limiting factor for sufficient delivery of drugs in tumors. Ultrasound in combination with microbubbles causing cavitation, is reported to improve delivery of nanoparticles (NPs) and drugs to tumors. Acoustic radiation force (ARF) could also enhance the penetration of NPs in tumor ECM. In this work, a collagen gel was used a model for tumor ECM to study the effect of ARF on the penetration of NPs as well as deformation of collagen gels applying different ultrasound (US) parameters (varying pressure and duty cycle). The collagen gel was characterized, and diffusion of water and diffusion of NPs measured. The penetration of NPs into the gel and was measured by confocal laser scanning microscopy and numerical simulations was performed to determine the ARF and to estimate penetration distance and extent of deformation. ARF had no effect on the penetration of NPs into the collagen gels for the US parameters and gel used, whereas a substantial deformation was observed. The width of the deformation on the collagen gel surface corresponded to the US beam. Comparing ARF caused by attenuation within the gel and Langevin pressure caused by reflection at the gel-water surface, ARF was the dominant mechanism for the gel deformation. The experimental and theoretical results were consistent both with respect to NP penetration and gel deformation.

24 April 2025 in Optica
Verified
Journal Article
Open access
SMSimon Moser
Simon Moser
MLMia Kvåle Løvmo
Mia Kvåle Løvmo
FSFranziska Strasser
Franziska Strasser
JHJudith Hagenbuchner
Judith Hagenbuchner
MAMichael J. Ausserlechner
Michael J. Ausserlechner
MRMonika Ritsch-Marte
Monika Ritsch-Marte
Optical diffraction tomography (ODT) has emerged as a powerful tool for imaging biological cells in a non-invasive and label-free manner. However, conventional approaches using ODT by varying the illumination are plagued by the missing cone problem, which introduces ambiguity and deteriorates the axial resolution in the reconstruction. Although utilizing object rotation has the potential to yield an isotropic resolution, experimental control or prior retrieval of the rotational parameters is challenging. In this work, we demonstrate the ODT of multiple-scattering samples undergoing variable rotational motion, unlocking the potential for isotropic resolution in non-contact systems. We introduce a comprehensive reconstruction method to jointly retrieve both the sample and the rotational motion in 3D. An interferometric setup enables the recording of amplitude and phase data while the object is rotated in a non-contact manner around one or more chosen axes in an acoustofluidic device. We evaluate the tomographic reconstruction performance of the method for clusters of micro-beads and highlight its suitability for biomedical applications beyond single cells, demonstrating high-resolution reconstruction of dense cancer spheroids containing more than 100 cells.

4 June 2025 in Optics Express
Verified
Journal Article
Open access
SKSyed Muhammad Kazim
Syed Muhammad Kazim
FSFranziska Strasser
Franziska Strasser
MLMia Kvåle Løvmo
Mia Kvåle Løvmo
ANAndrii Nehrych
Andrii Nehrych
SMSimon Moser
Simon Moser
MRMonika Ritsch-Marte
Monika Ritsch-Marte
We demonstrate coded wavefront sensing (Coded WFS) for video-rate quantitative phase imaging and 3D refractive index (RI) tomography of biological specimens. To evaluate the accuracy, we implement an experimental setup that supports measurements of specimens with Coded WFS as well as with digital holographic microscopy (DHM) under identical conditions, enabling direct comparison. We image a static 3D phantom fabricated via additive manufacturing and a rotating HEK293 cell in an acoustofluidic chamber. Our results demonstrate good agreement between the two methods, with the advantage that, in contrast to DHM, Coded WFS enables simple integration with standard microscopes. Furthermore, we apply a standard tomographic reconstruction algorithm to the HEK293 cell data for comparison, which demonstrates the potential of Coded WFS in tomography.

2 December 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
SMSimon Moser
Simon Moser
MLMia Kvale Lovmo
Mia Kvale Lovmo
FSFranziska Strasser
Franziska Strasser
JHJudith Hagenbuchner
Judith Hagenbuchner
MAMichael Ausserlechner
Michael Ausserlechner
MRMonika Ritsch-Marte
Monika Ritsch-Marte
Optical Diffraction Tomography (ODT) has emerged as a powerful tool for imaging biological cells in a non-invasive and label-free manner. However, conventional approaches using ODT by varying the illumination are plagued by the missing cone problem, which introduces ambiguity and deteriorates the axial resolution in the reconstruction. Although utilizing object rotation has the potential to yield isotropic resolution, experimental control or prior retrieval of the rotational parameters is challenging. In this work, we demonstrate ODT of multiple-scattering samples undergoing variable rotational motion, unlocking the potential for isotropic resolution in non-contact systems. We introduce a comprehensive reconstruction method to jointly retrieve both sample and rotational motion in 3D. An interferometric setup enables the recording of amplitude and phase data while the object is rotated in a non-contact manner around one or more chosen axes in an acoustofluidic device. We evaluate the tomographic reconstruction performance of the method for clusters of micro-beads and highlight its suitability for biomedical application beyond single cells, demonstrating high-resolution reconstruction of dense cancer spheroids containing more than 100 cells.