Bryan J. Johnson

Bryan J. Johnson

Auto-generated profile, based on publicly available information

Bryan J. Johnson

NOAA Global Monitoring Laboratory Boulder CO USA

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2017 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
JWJacquelyn C. Witte
Jacquelyn C. Witte
ATAnne M. Thompson
Anne M. Thompson
HSHerman G. J. Smit
Herman G. J. Smit
MFMasatomo Fujiwara
Masatomo Fujiwara
FPFrançoise Posny
Françoise Posny
FSFrancisco R. da Silva
Francisco R. da Silva
Electrochemical concentration cell ozonesonde measurements are an important source of highly resolved vertical profiles of ozone (O3) with long‐term data records for deriving O3trends, model development, satellite validation, and air quality studies. Ozonesonde stations employ a range of operational and data processing procedures, metadata reporting, and instrument changes that have resulted in inhomogeneities within individual station data records. A major milestone is the first reprocessing of seven Southern Hemisphere ADditional OZonesondes (SHADOZ) station ozonesonde records to account for errors and biases in operating/processing procedures. Ascension Island, Hanoi, Irene, Kuala Lumpur, La Réunion, Natal, and Watukosek station records all show an overall increase in O3after reprocessing. Watukosek shows the largest increase of 9.0 ± 2.1 Dobson Units (DU) in total column O3; Irene and Hanoi show a 5.5 ± 2.5 DU increase, while remaining sites show statistically insignificant enhancements. Negligible to modest O3enhancements are observed after reprocessing in the troposphere (up to 8%) and stratosphere (up to 6%), except at La Réunion for which the application of background currents reduces tropospheric O3(−2.1 ± 1.3 DU). Inhomogeneities due to ozonesonde/solution‐type changes at Ascension, Natal, and La Réunion are resolved with the application of transfer functions. Comparisons with EP‐TOMS, Aura's Ozone Monitoring Instrument and Microwave Limb Sounder (MLS) satellite O3overpasses show an overall improvement in agreement after reprocessing. Most reprocessed data sets show a significant reduction in biases with MLS at the ozone maximum region (50–10 hPa). Changes in radiosonde/ozonesonde system and nonstandard solution types can account for remaining discrepancies observed at several sites when compared to satellites.

18 October 2017 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
ATAnne M. Thompson
Anne M. Thompson
JWJacquelyn C. Witte
Jacquelyn C. Witte
CSChance Sterling
Chance Sterling
AJAllen Jordan
Allen Jordan
BJBryan J. Johnson
Bryan J. Johnson
KTKennedy Thiongo
Kennedy Thiongo
The Southern Hemisphere ADditional OZonesonde (SHADOZ) network was assembled to validate a new generation of ozone‐monitoring satellites and to better characterize the vertical structure of tropical ozone in the troposphere and stratosphere. Beginning with nine stations in 1998, more than 7,000 ozone and P‐T‐U profiles are available from 14 SHADOZ sites that have operated continuously for at least a decade. We analyze ozone profiles from the recently reprocessed SHADOZ data set that is based on adjustments for inconsistencies caused by varying ozonesonde instruments and operating techniques. First, sonde‐derived total ozone column amounts are compared to the overpasses from the Earth Probe/Total Ozone Mapping Spectrometer, Ozone Monitoring Instrument, and Ozone Mapping and Profiler Suite satellites that cover 1998–2016. Second, characteristics of the stratospheric and tropospheric columns are examined along with ozone structure in the tropical tropopause layer (TTL). We find that (1) relative to our earlier evaluations of SHADOZ data, in 2003, 2007, and 2012, sonde‐satellite total ozone column offsets at 12 stations are 2% or less, a significant improvement; (2) as in prior studies, the 10 tropical SHADOZ stations, defined as within ±19° latitude, display statistically uniform stratospheric column ozone, 229 ± 3.9 DU (Dobson units), and a tropospheric zonal wave‐one pattern with a 14 DU mean amplitude; (3) the TTL ozone column, which is also zonally uniform, masks complex vertical structure, and this argues against using satellites for lower stratospheric ozone trends; and (4) reprocessing has led to more uniform stratospheric column amounts across sites and reduced bias in stratospheric profiles. As a consequence, the uncertainty in total column ozone now averages 5%.

26 February 2021 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
WSWolfgang Steinbrecht
Wolfgang Steinbrecht
DKDagmar Kubistin
Dagmar Kubistin
CPChristian Plass‐Dülmer
Christian Plass‐Dülmer
JDJonathan Davies
Jonathan Davies
DTDavid Tarasick
David Tarasick
OCOwen R. Cooper
Owen R. Cooper
Throughout spring and summer 2020, ozone stations in the northern extratropics recorded unusually low ozone in the free troposphere. From April to August, and from 1 to 8 kilometers altitude, ozone was on average 7% (≈4 nmol/mol) below the 2000–2020 climatological mean. Such low ozone, over several months, and at so many stations, has not been observed in any previous year since at least 2000. Atmospheric composition analyses from the Copernicus Atmosphere Monitoring Service and simulations from the NASA GMI model indicate that the large 2020 springtime ozone depletion in the Arctic stratosphere contributed less than one‐quarter of the observed tropospheric anomaly. The observed anomaly is consistent with recent chemistry‐climate model simulations, which assume emissions reductions similar to those caused by the COVID‐19 crisis. COVID‐19 related emissions reductions appear to be the major cause for the observed reduced free tropospheric ozone in 2020.

15 March 2021 in Earth and Space Science
Verified
Journal Article
Open access
PDF file
DTDavid Tarasick
David Tarasick
HSHerman G. J. Smit
Herman G. J. Smit
ATAnne M. Thompson
Anne M. Thompson
GMGary A. Morris
Gary A. Morris
JWJacquelyn C. Witte
Jacquelyn C. Witte
HVHolger Vömel
Holger Vömel
We review the current state of knowledge of ozonesonde uncertainty and bias, with reference to recent developments in laboratory and field experiments. In the past 20 years ozonesonde precision has improved by a factor of 2, primarily through the adoption of strict standard operating procedures. The uncertainty budget for the ozone partial pressure reading has contributions from stoichiometry, cell background current, pump efficiency and temperature, sensing solution type, and volume. Corrections to historical data for known issues may reduce biases but simultaneously introduce additional uncertainties. This paper describes a systematic approach to quantifying these uncertainties by considering the physical and chemical processes involved and attempts to place our estimates on a firm theoretical or empirical footing. New equations or tables for ozone/iodine conversion efficiency, humidity and temperature corrections to pump flow rate, and altitude‐dependent pump flow corrections are presented, as well as detailed discussion of stoichiometry and conversion efficiencies. The nature of the so‐called “background current” is considered in detail. Two other factors particularly affecting past measurements, uncertainties and biases in the pressure measurement, and the comparison of sonde profiles to spectrophotometric measurements of total column ozone, are also discussed. Several quality assurance issues remain, but are tractable problems that can be addressed with further research. This will be required if the present goal of better than 5% overall uncertainty throughout the global ozonesonde network is to be achieved.

21 October 2022 in Earth and Space Science
Verified
Journal Article
Open access
RSRyan Stauffer
Ryan Stauffer
ATAnne M. Thompson
Anne M. Thompson
DKDebra E. Kollonige
Debra E. Kollonige
DTDavid W. Tarasick
David W. Tarasick
RMRoeland Van Malderen
Roeland Van Malderen
MYMichael M. Yan
Michael M. Yan
The recent Assessment of Standard Operating Procedures for Ozonesondes 2.0 (WMO/GAW Report #268) addressed questions of homogeneity and long‐term stability in global electrochemical concentration cell (ECC) ozone sounding network time series. Among its recommendations was adoption of a standard for evaluating data quality in ozonesonde time series. Total column ozone (TCO) derived from the sondes compared to TCO from Aura's Ozone Monitoring Instrument (OMI) is a primary quality indicator. Comparisons of sonde ozone with Aura's Microwave Limb Sounder (MLS) are used to assess the stability of stratospheric ozone. This paper provides a comprehensive examination of global ozonesonde network data stability and accuracy since 2004 in light of the sudden post‐2013 TCO “dropoff” of ∼3%–4% that was reported previously at select stations (Stauffer et al., 2020, https://doi.org/10.1029/2019GL086791). Comparisons with Aura OMI TCO averaged across the network of 60 stations are stable within about ±2% over the past 18 years. Sonde TCO has similar stability compared to three other TCO satellite instruments, and the stratospheric ozone measurements average to within ±5% of MLS from 50 to 10 hPa. Thus, sonde data are reliable for trends, but with a caveat applied for a subset of dropoff stations in the tropics and subtropics. The dropoff is associated with only one of two major ECC instrument types. A detailed examination of ECC serial numbers pinpoints the timing of the dropoff. However, we find that overall, ozonesonde data are stable and accurate compared to independent measurements over the past two decades.

4 June 2020 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
RSRyan Stauffer
Ryan Stauffer
ATAnne M. Thompson
Anne M. Thompson
DKDebra E. Kollonige
Debra E. Kollonige
JWJacquelyn C. Witte
Jacquelyn C. Witte
DTDavid Tarasick
David Tarasick
HSHerman G. J. Smit
Herman G. J. Smit
An international effort to improve ozonesonde data quality and to reevaluate historical records has made significant improvements in the accuracy of global network data. However, between 2014 and 2016, ozonesonde total column ozone (TCO; O3) at 14 of 37 regularly reporting stations exhibited a sudden dropoff relative to satellite measurements. The ozonesonde TCO drop is 3–7% compared to satellite and ground‐based TCO, and 5–10% or more compared to satellite stratospheric O3 profiles, compromising the use of recent data for trends, although they remain reliable for other uses. Hardware changes in the ozonesonde instrument are likely a major factor in the O3 dropoff, but no single property of the ozonesonde explains the findings. The bias remains in recent data. Research to understand the dropoff is in progress; this letter is intended as a caution to users of the data. Our findings underscore the importance of regular ozonesonde data evaluation.