Branislav Grajciar

Branislav Grajciar

Auto-generated profile, based on publicly available information

Branislav Grajciar

Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringerstrasse 13, A-1090 Vienna, Austria

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2010 in Optics Express
Verified
Journal Article
Open access
PDF file
BGBranislav Grajciar
Branislav Grajciar
YLYves Lehareinger
Yves Lehareinger
AFAdolf F. Fercher
Adolf F. Fercher
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
In this paper we present an ultra high speed and highly phase sensitive line-field FD-OCT system for quantitative phase mapping. The system works with a maximum speed of 512 000 A-scan/s (1000 fps) in real time mode. Along the parallel recorded direction excellent phase stability corresponding to a path length variation of only 510 pm was measured. We demonstrate how to exploit this phase accuracy for fast chemical analysis of glucose mixture processes. The system has particular potential for studying micro-fluidic processes.

1 January 2008 in Optics Express
Verified
Journal Article
Closed access
PDF file
BGBranislav Grajciar
Branislav Grajciar
Michael PircherMichael Pircher
Michael Pircher
CHChristoph Hitzenberger
Christoph Hitzenberger
OFOliver Findl
Oliver Findl
AFAdolf F. Fercher
Adolf F. Fercher
In this paper we present a system for intraocular distance measurement of the human eye in vivo with high sensitivity. The instrument is based on Fourier domain low coherence interferometry (FD-LCI). Stateof-the-art FD-LCI systems are limited to a depth range of only a few mm, because the depth range is determined by the spectral resolution of the spectrometer. To measure larger distances (e.g. human eye length) we implemented two separate reference arms with different arm lengths into the interferometer. Each reference arm length corresponds to a different depth position within the sample (e.g. cornea and retina). Therefore two different depth sections, each with a depth range of a few mm can be imaged simultaneously. With the new system axial distances could be measured with a precision of 8µm. We demonstrate the performance of the instrument by measuring the axial eye length of 9 patients with cataract and compare our results with those obtained using the IOL Master (Carl Zeiss Meditec Inc.).

31 December 2011 in Photonics Letters of Poland
Verified
Journal Article
Closed access
BGBranislav Grajciar
Branislav Grajciar
MHMelanie Herdin
Melanie Herdin
CBCedric Blatter
Cedric Blatter
MGMartin Gröschl
Martin Gröschl
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb

1 September 2006
Verified
Conference Paper
Closed access
BGBranislav Grajciar
Branislav Grajciar
OOOldrich Ondracek
Oldrich Ondracek
Optical coherence tomography (OCT) is a non-invasive interferometric imaging technique offering millimeter penetration depths of a sample with outstanding axial resolution. In this work a parallel Fourier domain optical coherence tomography (FD OCT) system is presented which records full tomograms of the sample structure in parallel. A fully parallel FD OCT system allows fast real time imaging of biological tissues.