6 May 2019 in IEEE Systems Journal
The safety and security of load frequency control (LFC) system are menaced by cyber attacks and physical attacks. Sophisticated attackers can launch cyber-physical attacks (CPAs), in which cyber attacks are used to increase the impacts of physical attacks by sending wrong instructions to the LFC controller. Considering that parameters of cyber attacks in CPAs may be either fixed or variable, a novel detection scheme is designed against two potential CPAs on an LFC system, namely fixed cyber-physical attacks (FCPAs) and variable cyber-physical attacks (VCPAs), respectively. As for FCPAs, dynamic characteristics of Area Control Error (ACE) are utilized to detect the compromised data. Compared with FCPAs, VCPAs are more deceptive. A relation-based (RB) feature extraction method is introduced to distinguish the signals compromised by VCPAs from the normal ones. A detection model that does not require compromised samples is developed with the aid of support vector domain description. In the end, a comprehensive detection scheme is designed to detect both FCPAs and VCPAs on the LFC system.
14 June 2023 in IEEE Transactions on Power Systems
The highly variable nature of renewable energy has led to the concept of intra-day look-ahead unit commitment (LAUC), which aims to determine the on/off status and power outputs of generating units in a rolling-horizon fashion. LAUC is traditionally performed based on look-ahead horizon (LAH) with fixed length and resolution. Such practice can neither capture the high-risk time periods, nor achieve maximum computational efficiency. To address these issues, this article proposes a LAUC method with adaptive horizon (LAUC-AH). The method uses three parameters to describe the shape of LAH, namely length, resolution, and myopia. Taking these parameters, the forecast profile of renewable energy and load demand is aggregated using a hierarchical clustering procedure to form the LAH, which is then used to construct the LAUC optimization model. Furthermore, a deep reinforcement learning-based agent is used to dynamically adjust the parameters of LAH, such that the LAUC model can adapt to different operation statuses of the power grid. The case studies are carried out on a modified IEEE-118 test case to validate the feasibility and effectiveness of the proposed method.
1 January 2014 in The Scientific World Journal
Cooperative regulation of multiagent systems has become an active research area in the past decade. This paper reviews some recent progress in distributed coordination control for leader-following multiagent systems and its applications in power system and mainly focuses on the cooperative tracking control in terms of consensus tracking control and containment tracking control. Next, methods on how to rank the network nodes are summarized for undirected/directed network, based on which one can determine which follower should be connected to leaders such that partial followers can perceive leaders’ information. Furthermore, we present a survey of the most relevant scientific studies investigating the regulation and optimization problems in power systems based on distributed strategies. Finally, some potential applications in the frequency tracking regulation of smart grids are discussed at the end of the paper.
1 November 2015 in Neurocomputing
21 November 2023 in IEEE Transactions on Industrial Informatics
The vital importance of the relay protection system makes it difficult for attackers to attack it directly. This article points out an innovative indirect coordinated attack (ICA) against the relay, which is initiated by manipulating load-side power electronics to generate false signals, to induce relays to malfunction and thus override trip. First, this article analyzes the vulnerability of the load-side power electronic and the potential for manipulating it to cause relay to malfunction. Next, this article investigates the principles and consequences of two indirect attacks, resulting in the blocking or tripping of the directional overcurrent relay (DOCR), respectively. Notably, if these two indirect attacks are combined into the ICA, it can penetrate through multiple DOCRs, posing a considerable threat to the security of the power system. To cope with it, a defense strategy is proposed, which is to implement a blocking reasons identification technology (BRIT) as a built-in function in DOCRs. BRIT employs the recursive feature elimination method to select optimal features and then identifies the actual overcurrent signal based on bidirectional LSTMto defend against the faulty blocking caused by the ICA. Consequently, it prevents the tripping signal from causing more extensive damage. The performance of the ICA process and the defense strategy is validated using the CIGRE low-voltage microgrid example system.