24 January 2022 in Physics of Fluids
Respiratory droplets—which may contain disease spreading virus—exhaled during speaking, coughing, or sneezing are one of the significant causes for the spread of the ongoing COVID-19 pandemic. The droplet dispersion depends on the surrounding air velocity, ambient temperature, and relative humidity. In a confined space like an elevator, the risk of transmission becomes higher when there is an infected person inside the elevator with other individuals. In this work, a numerical investigation is carried out in a three-dimensional domain resembling an elevator using OpenFoam. Three different modes of air ventilation, viz., quiescent, axial exhaust draft, and exhaust fan, have been considered to investigate the effect of ventilation on droplet transmission for two different climatic conditions (30 °C, 50% relative humidity and 10 °C, 90% relative humidity). The risk assessment is quantified using a risk factor based on the time-averaged droplet count present near the passenger's hand to head region (risky height zone). The risk factor drops from 40% in a quiescent scenario to 0% in an exhaust fan ventilation condition in a hot dry environment. In general, cold humid conditions are safer than hot dry conditions as the droplets settle down quickly below the risky height zone owing to their larger masses maintained by negligible evaporation. However, an exhaust fan renders the domain in a hot dry ambience completely safe (risk factor, 0%) in 5.5 s whereas it takes 7.48 s for a cold humid ambience.
11 August 2015 in Journal of Heat Transfer
20 January 2020 in Journal of Thermal Analysis and Calorimetry
1 March 2013 in International Journal of Spray and Combustion Dynamics
The study characterizes the behavior of a premixed swirl stabilized dump plane combustor flame near its lean blow-out (LBO) limit in terms of CH* chemiluminiscence intensity and observable flame color variations for a wide range of equivalence ratio, flow rates and degree of premixing (characterized by premixing length, L fuel). LPG and pure methane are used as fuel. We propose a novel LBO prediction strategy based solely on the flame color. It is observed that as the flame approaches LBO, its color changes from reddish to blue. This observation is found to be valid for different levels of fuel-air premixing achieved by changing the available mixing length of the air and the fuel upstream of the dump plane although the flame dynamics were significantly different. Based on this observation, the ratio of the intensities of red and blue components of the flame as captured by a color CCD camera was used as a metric for detecting the proximity of the flame to LBO. Tests were carried out for a wide range of air flow rates and using LPG and CH4 as fuel. For all the operating conditions and both fuels tested, this ratio was found to monotonically decrease as LBO was approached. Moreover, the value of this ratio was within a small range close to LBO for all the cases investigated. This makes the ratio suitable as a metric for LBO detection at all levels of premixing.
1 February 2021 in International Communications in Heat and Mass Transfer
1 September 2015 in International Journal of Spray and Combustion Dynamics
This paper addresses dynamic data-driven prediction of lean blowout (LBO) phenomena in confined combustion processes, which are prevalent in many physical applications (e.g., land-based and aircraft gas-turbine engines). The underlying concept is built upon pattern classification and is validated for LBO prediction with time series of chemiluminescence sensor data from a laboratory-scale swirl-stabilized dump combustor. The proposed method of LBO prediction makes use of the theory of symbolic dynamics, where (finite-length) time series data are partitioned to produce symbol strings that, in turn, generate a special class of probabilistic finite state automata (PFSA). These PFSA, called D-Markov machines, have a deterministic algebraic structure and their states are represented by symbol blocks of length D or less, where D is a positive integer. The D-Markov machines are constructed in two steps: (i) state splitting, i.e., the states are split based on their information contents, and (ii) state merging, i.e., two or more states (of possibly different lengths) are merged together to form a new state without any significant loss of the embedded information. The modeling complexity (e.g., number of states) of a D-Markov machine model is observed to be drastically reduced as the combustor approaches LBO. An anomaly measure, based on Kullback-Leibler divergence, is constructed to predict the proximity of LBO. The problem of LBO prediction is posed in a pattern classification setting and the underlying algorithms have been tested on experimental data at different extents of fuel-air premixing and fuel/air ratio. It is shown that, over a wide range of fuel-air premixing, D-Markov machines with D > 1 perform better as predictors of LBO than those with D = 1.