1 January 2017 in AIP Conference Proceedings
Growth of world energy consumption and depletion of energy resources make humanity to constantly work on the creation of the energy efficient technologies and increase usage of the alternative and renewable sources of energy. One of such alternative sources of energy is the night radiative cooling (NRC). NRC is an alternative and renewable source of energy, derived from the effective radiation of the Earth into the Space. If the given surface is located so that it looks to the night sky, then under the particular condition more energy can be generated under the effect of radiative cooling, than received from the atmosphere. As a result the temperature of the surface can be kept lower than the temperature of the ambient air. This effect can be used for creation of the refrigeration systems with the low energy consumption and as a result lower negative influence on the environment. During the research it has been identified that the possibility of the NRC usage is mostly predetermined by the specifics of the climate of the each region. In particular climate conditions the refrigeration systems working on night radiative cooling will be more effective that in others.
23 August 2018 in AIP Conference Proceedings
Various methods of natural cooling are used to solve the problem of global warming and increase the energy efficiency of refrigeration systems. One of such methods is radiation cooling to outer space. In this paper we consider the possibility of using radiation cooling to lower the temperature of the liquid entering the processing once a day at 5:00. For cooling is proposed a system that is a cylindrical tank with a cooling casing. The coolant in the casing is cooled by the action of the radiators at night. The system is operated in the climatic conditions of the moderately cold climate of the Ust-Kamenogorsk city (Kazakhstan), located at 49°58’N. To assess the efficiency of the system, its mathematical modeling was carried out based on the solution of the heat balance equations. As a result of the simulation, data were obtained on the temperature and heat fluxes in the system during the year. It is found that the cooled liquid reaches the required temperature (<+ 5 °C) three hours after loading into the system for 123 days a year. The average daily specific cooling capacity of radiators reaches from 50 to 150 W/m2 in winter and in the summer this value does not exceed 30 W/m2.
30 April 2022 in Eastern-European Journal of Enterprise Technologies
The surface of the Earth is a source of radiation of thermal energy, which, passing through the atmosphere, is partially absorbed while the bulk of the energy is released into the surrounding outer space. A cooling technique based on this physical phenomenon is known as radiative cooling (RC). It is possible to reduce the consumption of electricity for cooling, as well as to reduce capital costs, by integrating the unit with radiative cooling directly into the circulation circuit of the refrigerant of the refrigeration machine. An experimental refrigeration system has been designed, in which in the cold periods of the year the removal of heat from the cooled object is carried out due to the mode of natural circulation of the refrigerant from the evaporator to the heat exchanger, cooled by radiative cooling. A refrigeration system with natural circulation and radiative cooling of the refrigerant R134a was experimentally studied during the autumn period in Almaty. The experimental study established that the chamber is cooled with the help of the examined system while the temperature in the cooled volume is maintained by 5...7 K above ambient air temperature at night. The dependence of the air temperature in the refrigerating chamber on the temperature of the atmospheric air has been determined. A procedure for assessing the cooling capacity of the system has been devised. The study reported here demonstrated the possibility of using radiative cooling to remove heat under the mode of natural circulation of the refrigerant. The refrigeration system reduces energy consumption in the cold seasons by diverting heat to the environment without the compressor operating
25 February 2022 in Eastern-European Journal of Enterprise Technologies
In regions with a continental climate, refrigerators with air-cooled condensers operate at high condensation pressures during the summer season which reduces their efficiency and accelerates the wear of compressors. To reduce condensation pressure, it was proposed to use radiative cooling which is a way of heat removal through the planet's atmosphere to outer space in a form of infrared radiation. A refrigerating machine with an assembly of condensation heat removal including air and liquid cooling condensers connected in series has been developed. To reduce the condensation temperature, a pre-cooled heat-transfer agent is fed to the liquid cooling condenser during the day hours at high atmospheric temperatures. At night, the heat-transfer agent is cooled by radiative cooling. An experimental study of the operation of a 600 W refrigerating machine including a sealed piston compressor was conducted. R134a refrigerant was used. Supply of pre-cooled heat-transfer agent at +33.1 °С has provided a reduction of condensation temperature from +47.0 to +39.1 °С. The study was conducted at an atmospheric air temperature of +38.0 °С. The degree of pressure growth was decreased by 30 %. The refrigeration coefficient was increased by 11 %. In comparison with the conventional scheme with an air-cooled condenser, energy consumption by the system did not change in the daytime. The offered scheme of condensation heat removal reduces the pressure of condensation and provides stability for refrigerating machine operation. It can be used in stationary refrigerating machines at high daytime temperatures.
25 February 2023 in Eastern-European Journal of Enterprise Technologies
The work examines the heat exchange characteristics of a condenser in which heat removal of the refrigerant condensation occurs due to natural convection and radiation cooling. The heat exchanger is designed to reduce energy costs for the removal of condensation heat. Unlike traditional air cooling condensers, it uses radiation cooling, a method of heat removal based on its transmission in the form of infrared radiation through the planet’s atmosphere into the surrounding outer space. A method for calculating the thickness of the radiating plate has been developed. To minimize material consumption and cost, the distance between the tubes is reduced to 40 mm, and the thickness of the aluminum radiating plate is reduced to 0.32 mm. The inner diameter of the coolant channels is 1 mm. For the experimental study of the condenser, an experimental stand working on R134a refrigerant was developed. Theoretical and experimental studies of heat transfer have been carried out. The heat transfer coefficient of the heat exchanger, reduced to the area of the radiating surface, was from 10.3±1.36 to 18.7±2.47 W·m–2·°C–1, when the condensation temperature was 12.8...21.9 °С higher than the temperature of atmospheric air. The operability of the condenser is shown both during the day and at night, in the presence of precipitation in the form of rain and snow, and a high level of cloudiness. The material capacity and filling of the refrigerant in the condenser are comparable to the characteristics of air-cooled condensers with forced air circulation. At the same time, it does not consume electricity. It can be used in stationary refrigeration systems (in data processing centers, commercial refrigeration equipment, air conditioners) to increase their energy efficiency