Methanol plays an important role in studying the structure and dynamics of hydrogen bonds in alcohols and other physiologically important compounds in the condensed state. The physical vapor deposition method and two-beam interferometry make it possible to study the structure of polyatomic molecules, the nature and character of intermolecular interactions, and the internal structure of various compounds. Thus, it becomes possible to analyze changes in the internal structure of substances near the points of their phase transitions and glass transitions at ultralow temperatures. In this work, we have studied the effect of nitrogen and nitrous oxide on the dependence of refractive indices of methanol on temperature and on structural-phase transformations upon heating from 16 to 160 K.
The interaction of host molecules with water molecules is of primary importance in astrophysical and atmospheric studies. Water-binding interactions continue to attract a broad interest in various fields, especially those related to the formation of assembly structures. Using the physical vapor deposition (PVD) method and a two-beam interferometer with a wavelength of 406 nm, the refractive indices of thin films of a water and nitrogen (argon) mixture were calculated in the range from 15 to 35 K. The results of temperature transformations of the obtained films from a two-beam interferometer, and thermal desorption characteristics from the temperature of condensation to the temperature of evaporation of water (15–180 K), are presented. The relationship between the signal of the interferometer, the refractive index, and the film thickness during glass transition is demonstrated.
In this work, the temperature distribution on a cryosurface operating at low temperatures (in the range from 300 K to 80 K) was thoroughly studied. This type of cryogenic cooling surface is specifically designed for experimental processes that involve the controlled deposition and subsequent cooling of various inorganic compounds. Such processes are essential for conducting detailed investigations into the physicochemical properties, morphology, and structure of these materials under cryogenic conditions. The temperature distribution was analyzed through numerical simulation, which included modeling the cooling process of the cryopanel surface down to cryogenic temperatures using the finite element method. Liquid nitrogen was selected as the working coolant due to its availability, low boiling point, and high efficiency in achieving the required cooling rate. The simulation results revealed the temperature gradient both within the volume and on the surface of the cryopanel. Additionally, the influence of the thermal conductivity of different structural materials–aluminum and stainless steel–on the cooling efficiency was examined. The desired cryosurface temperature range (80–90 K) was successfully reached within 1800 seconds, using a nitrogen flow through a coiled pipe of 6 mm in diameter. Key words: cryosurface, computer modelling, thermal distribution, low temperatures, thermal conductiv ity.
25 February 2022 in Eastern-European Journal of Enterprise Technologies
In regions with a continental climate, refrigerators with air-cooled condensers operate at high condensation pressures during the summer season which reduces their efficiency and accelerates the wear of compressors. To reduce condensation pressure, it was proposed to use radiative cooling which is a way of heat removal through the planet's atmosphere to outer space in a form of infrared radiation. A refrigerating machine with an assembly of condensation heat removal including air and liquid cooling condensers connected in series has been developed. To reduce the condensation temperature, a pre-cooled heat-transfer agent is fed to the liquid cooling condenser during the day hours at high atmospheric temperatures. At night, the heat-transfer agent is cooled by radiative cooling. An experimental study of the operation of a 600 W refrigerating machine including a sealed piston compressor was conducted. R134a refrigerant was used. Supply of pre-cooled heat-transfer agent at +33.1 °С has provided a reduction of condensation temperature from +47.0 to +39.1 °С. The study was conducted at an atmospheric air temperature of +38.0 °С. The degree of pressure growth was decreased by 30 %. The refrigeration coefficient was increased by 11 %. In comparison with the conventional scheme with an air-cooled condenser, energy consumption by the system did not change in the daytime. The offered scheme of condensation heat removal reduces the pressure of condensation and provides stability for refrigerating machine operation. It can be used in stationary refrigerating machines at high daytime temperatures.
This paper evaluated the operation of a universal cryopanel designed to cool surfaces to cryogenic temperatures using an experimental and computer study. The cryopanel’s structure comprises prefabricated parts: a lower plate and a top plate featuring 2.3 mm high pins, through which cooled nitrogen flows. The main aim of this work was to assess the performance of the universal cryopanel design through thermal and mechanical numerical modeling to meet the demands of different operating modes. Using the COMSOL Multiphysics software version 6.1, it has been shown that the optimized design achieves the required temperature of 150 K and lower on the top surface of the panel with a constant inlet temperature of 80 K and a flow rate of 0.05 m/s. Experimental data on the operation of cryopanels was compared with the resulting model. Data on the cryopanel and research at cryotemperatures will find application in medicine, the food industry, electronics, and scientific research on deposition and condensation, where it is important to observe operating modes and maintain low temperatures.
This paper presents a study of cooling cryopanels to liquid nitrogen temperatures. Using computer modeling methods, in particular the finite element method and computational fluid dynamics, the temperature and time dependences of the average temperature over the volume and surface of a cryopanel with a single flow line, in contrast to multichannel structures, were obtained. The considered diameters (3, 5, or 7 mm) of the liquid nitrogen flow line showed the effect of the diameter on the cooling intensity: a larger channel diameter leads to more intense surface cooling. In addition, a larger coil diameter leads to a faster achievement of temperature equilibrium over the entire studied surface. This flow line configuration also demonstrated an advantageous concentration of the cooling zone in the central working area of the panel. These results provide critical information for optimizing the design of universal cryopanels, ensuring more efficient and controlled cooling for various applications.