Brandon A. Miller

Brandon A. Miller

Auto-generated profile, based on publicly available information

Brandon A. Miller

Exercise Science Program, Kent State University, Kent, OH, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2022 in Brain, Behavior, & Immunity - Health
Verified
Journal Article
Open access
EAEliott Arroyo
Eliott Arroyo
ETEmily C. Tagesen
Emily C. Tagesen
THTricia L. Hart
Tricia L. Hart
BMBrandon A. Miller
Brandon A. Miller
Adam JajtnerAdam Jajtner
Adam Jajtner
The purpose of this investigation was to compare changes in circulating lymphocyte subset cell counts between high-intensity interval exercise (HIIE), sprint interval exercise (SIE), and moderate-intensity continuous exercise (MICE). Recreationally active men (n ​= ​11; age: 23 ​± ​4 ​yr; height: 179.9 ​± ​4.5 ​cm; body mass: 79.8 ​± ​8.7 ​kg; body fat %:12.6 ​± ​3.8%; V̇O2max: 46.6 ​± ​3.9 ​ml⋅kg−1⋅min−1) completed a maximal graded exercise test to determine maximal oxygen uptake (V̇O2max) and three duration-matched cycling trials (HIIE, SIE, and MICE) in a randomized, counterbalanced fashion. HIIE consisted of fifteen 90-s bouts at 85% V̇O2max interspersed with 90-s active recovery periods. SIE consisted of fifteen 20-s bouts at 130% maximal power and 160-s active recovery periods. MICE was a continuous bout at 65% V̇O2max. Total exercise duration was 53 ​min in all three trials, including warm-up and cool-down. Blood was collected before, immediately post, 30 ​min, 2 ​h, 6 ​h, and 24 ​h post-exercise. Changes in lymphocyte subset counts, and surface expression of various markers were analyzed via flow cytometry. Changes were assessed using mixed model regression analysis with an autoregressive first order repeated measures correction. Significant decreases were observed in absolute counts of CD56dim NK cells, CD19+ B cells, CD4+ T cells, and CD8+ T cells 30 ​min and 24-h post-exercise in all three trials. Despite resulting in greater total work and oxygen consumption, MICE elicited similar changes in lymphocyte subset counts and receptor expression compared to both SIE and HIIE. Similarly, while the two interval trials resulted in differing oxygen consumption and total work, no differences in the lymphocyte response were observed. Though both forms of exercise resulted in declines in circulating lymphocyte cell counts, neither exercise type provides an immune-related advantage when matched for duration.

1 October 2012 in Neurosurgery Clinics of North America
Verified
Journal Article
Closed access
BMBrandon A. Miller
Brandon A. Miller
WRW. Caleb Rutledge
W. Caleb Rutledge
AIAdriana G. Ioachimescu
Adriana G. Ioachimescu
NONelson M. Oyesiku
Nelson M. Oyesiku

10 September 2018 in Child's Nervous System
Verified
Journal Article
Open access
PDF file
TCTravis S. CreveCoeur
Travis S. CreveCoeur
ASAfshin Salehi
Afshin Salehi
BMBrandon A. Miller
Brandon A. Miller
MAMatthew J. Austin
Matthew J. Austin
DCDewitte T. Cross
Dewitte T. Cross
MSMatthew D. Smyth
Matthew D. Smyth
Aneurysmal subarachnoid hemorrhage (SAH) is rare in neonates. The authors present a unique report of a neonate with SAH from anterior inferior cerebellar artery (AICA) aneurysm rupture that was successfully treated with Onyx embolization. This case report demonstrates the utility of Onyx embolization for posterior circulation aneurysms in neonates and the successful management of SAH in this population.

17 March 2020 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
BMBrandon A Miller
Brandon A Miller
RSRobert Christopher Spears
Robert Christopher Spears
THThomas K Hines
Thomas K Hines
AAAbdulnasser Alhajeri
Abdulnasser Alhajeri
JFJustin F Fraser
Justin F Fraser
Pediatric spinal vascular malformations are rare entities that typically present with symptoms from their effect on surrounding structures. Here we report a unique case of lumbar spinal dural/perimedullary arteriovenous fistula (AVF) that presented with intraventricular hemorrhage and hydrocephalus. The previously healthy child presented with lethargy and headache, and initial imaging revealed only ventriculomegaly with trace intraventricular blood. His mental status improved with CSF diversion via an external ventricular drain. Further workup revealed a spinal AVF that was treated via endovascular embolization. His course was complicated by vasospasm requiring endovascular treatment and he eventually required ventriculoperitoneal shunt placement. He made a full recovery and has returned to his normal activities. This is a unique case of spinal AVF presentation and highlights the importance of considering imaging of the entire neuroaxis during workup for hydrocephalus.

10 January 2016 in Neural Plasticity
Verified
Journal Article
Open access
PDF file
BMBrandon A. Miller
Brandon A. Miller
JGJohn C. Gensel
John C. Gensel
MBMichael S. Beattie
Michael S. Beattie

1 December 2018
Verified
Conference Paper
Closed access
SMSiavash Mazdeyasna
Siavash Mazdeyasna
Chong HuangChong Huang
Chong Huang
MZMingjun Zhao
Mingjun Zhao
ABAlisha R. Bonaroti
Alisha R. Bonaroti
KSKathryn Saatman
Kathryn Saatman
GYGuoqiang Yu
Guoqiang Yu
We modified and adapted a novel noncontact speckle contrast diffuse correlation tomography (scDCT) system, developed in our laboratory, for noninvasive 3D imaging of blood flow distributions in small animals and large human tissue volumes. The new system has the flexibility of selecting small and large regions of interest (ROIs) with different imaging depths for the use in both the small mouse head and large human mastectomy skin flaps. The capability of the upgraded scDCT system was demonstrated by continuous imaging of cerebral blood flow (CBF) changes in a small mouse head during sequential common carotid artery ligations and blood flow distributions in human mastectomy skin flaps during surgery. As expected, arterial occlusions resulted in substantial CBF decreases in deep brain tissues of the mouse. Spatial heterogeneity existed, and lower blood flow values were observed around the incision area of mastectomy skin flaps. The noncontact scDCT system with flexible ROIs and imaging depths has the potential to be used in many preclinical and clinical settings for noninvasive assessment of tissue hemodynamics and viability.