Infrared thermographs (IRTs) are commonly used during disease pandemics to screen individuals with elevated body temperature (EBT). To address the limited research on external factors affecting IRT accuracy, we conducted benchtop measurements and computer simulations with two IRTs, with or without an external temperature reference source (ETRS) for temperature compensation. The combination of an IRT and an ETRS forms a screening thermograph (ST). We investigated the effects of viewing angle (θ, 0–75°), ETRS set temperature (, 30–40 °C), ambient temperature (, 18–32 °C), relative humidity (RH, 15–80%), and working distance (d, 0.4–2.8 m). We discovered that STs exhibited higher accuracy compared to IRTs alone. Across the tested ranges of and RH, both IRTs exhibited absolute measurement errors of less than 0.97 °C, while both STs maintained absolute measurement errors of less than 0.12 °C. The optimal for EBT detection was 36–37 °C. When θ was below 30°, the two STs underestimated calibration source (CS) temperature () of less than 0.05 °C. The computer simulations showed absolute temperature differences of up to 0.28 °C and 0.04 °C between estimated and theoretical temperatures for IRTs and STs, respectively, considering d of 0.2–3.0 m, of 15–35 °C, and RH of 5–95%. The results highlight the importance of precise calibration and environmental control for reliable temperature readings and suggest proper ranges for these factors, aiming to enhance current standard documents and best practice guidelines. These insights enhance our understanding of IRT performance and their sensitivity to various factors, thereby facilitating the development of best practices for accurate EBT measurement.
Hyperspectral imaging (HSI) technology, which offers both spatial and spectral information, holds significant potential for enhancing diagnostic performance during endoscopy and other medical procedures. However, quantitative evaluation of HSI cameras is challenging due to various influencing factors (e.g., light sources, working distance, and illumination angle) that can alter the reflectance spectra of the same target as these factors vary. Towards robust, universal test methods, we evaluated several data normalization methods aimed at minimizing the impact of these factors. Using a high-resolution HSI camera, we measured the reflectance spectra of diffuse reflectance targets illuminated by two different light sources. These spectra, along with the reference spectra from the target manufacturer, were normalized with nine different methods (e.g., area under the curve, standard normal variate, and centering power methods), followed by a uniform scaling step. We then compared the measured spectra to the reference to evaluate the capability of each normalization method in ensuring a consistent, standardized performance evaluation. Our results demonstrate that normalization can mitigate the impact of some factors during HSI camera evaluation, with performance varying across methods. Generally, noisy spectra pose challenges for normalization methods that rely on limited reflectance values, while methods based on reflectance values across the entire spectrum (such as standard normal variate) perform better. The findings also suggest that absolute reflectance spectral measurements may be less effective for clinical diagnostics, whereas normalized spectral measurements are likely more appropriate. These findings provide a foundation for standardized performance testing of HSI-based medical devices, promoting the adoption of high-quality HSI technology for critical applications such as early cancer detection.
24 October 2024 in IEEE Transactions on Medical Imaging
To address many of the deficiencies in optical neuroimaging technologies, such as poor tempo-spatial resolution, low penetration depth, contact-based measurement, and time-consuming image reconstruction, a novel, noncontact, portable, time-resolved laser speckle contrast imaging (TR-LSCI) technique has been developed for continuous, fast, and high-resolution 2D mapping of cerebral blood flow (CBF) at different depths of the head. TR-LSCI illuminates the head with picosecond-pulsed, coherent, widefield near-infrared light and synchronizes a fast, high-resolution, gated single-photon avalanche diode camera to selectively collect diffuse photons with longer pathlengths through the head, thus improving the accuracy of CBF measurement in the deep brain. The reconstruction of a CBF map was dramatically expedited by incorporating convolution functions with parallel computations. The performance of TR-LSCI was evaluated using head-simulating phantoms with known properties and in-vivo rodents with varied hemodynamic challenges to the brain. TR-LSCI enabled mapping CBF variations at different depths with a sampling rate of up to 1 Hz and spatial resolutions ranging from tens/hundreds of micrometers on rodent head surfaces to 1-2 millimeters in deep brains. With additional improvements and validation in larger populations against established methods, we anticipate offering a noncontact, fast, high-resolution, portable, and affordable brain imager for fundamental neuroscience research in animals and for translational studies in humans.
1 December 2023 in IEEE Journal of Translational Engineering in Health and Medicine
Malignant glioma (MG) is the most common type of primary malignant brain tumors. Surgical resection of MG remains the cornerstone of therapy and the extent of resection correlates with patient survival. A limiting factor for resection, however, is the difficulty in differentiating the tumor from normal tissue during surgery. Fluorescence imaging is an emerging technique for real-time intraoperative visualization of MGs and their boundaries. However, most clinical grade neurosurgical operative microscopes with fluorescence imaging ability are hampered by low adoption rates due to high cost, limited portability, limited operation flexibility, and lack of skilled professionals with technical knowledge. To overcome the limitations, we innovatively integrated miniaturized light sources, flippable filters, and a recording camera to the surgical eye loupes to generate a wearable fluorescence eye loupe ( FLoupe ) device for intraoperative imaging of fluorescent MGs. Two FLoupe prototypes were constructed for imaging of Fluorescein and 5-aminolevulinic acid (5-ALA), respectively. The wearable FLoupe devices were tested on tumor-simulating phantoms and patients with MGs. Comparable results were observed against the standard neurosurgical operative microscope (PENTERO® 900) with fluorescence kits. The affordable and wearable FLoupe devices enable visualization of both color and fluorescence images with the same quality as the large and expensive stationary operative microscopes. The wearable FLoupe device allows for a greater range of movement, less obstruction, and faster/easier operation. Thus, it reduces surgery time and is more easily adapted to the surgical environment than unwieldy neurosurgical operative microscopes.
Extremely preterm infants’ hemodynamic instability places them at high risk of brain injury. Currently there is no reliable bedside method to continuously monitor cerebral hemodynamics in the neonatal intensive care unit (NICU). This paper reports a feasibility study to adapt and test an innovative speckle contrast diffuse correlation tomography (scDCT) device for noncontact, high-density, 3D imaging of cerebral blood flow (CBF) in preterm infants. The scDCT scans a focused point near-infrared illumination to multiple source positions for deep tissue penetration, and controls an electron multiplying charge-coupled-device camera with thousands of pixels to achieve a high-density sampling. The optimized scDCT for use in preterm infants was first evaluated against an established diffuse correlation spectroscopy in an infant-head-simulating phantom with known properties. The observed significant correlation between the two measurements verified the capability of scDCT for transcranial brain imaging. The insignificant influence of transparent incubator wall on scDCT measurements was then confirmed by comparing adult forearm blood flow responses to artery cuff occlusions measured inside and outside the incubator. Finally, the scDCT device was moved to the NICU to image CBF variations in two preterm infants. Infant #1 with no major organ deficits showed little CBF fluctuation over the first 3 weeks of life. Infant #2 showed a significant CBF increase after the 2 h pharmacotherapy for patent ductus arteriosus closure. While these CBF variations meet physiological expectations, the fact that no significant changes are noted with peripheral monitoring of blood oxygen saturation suggests necessity of direct cerebral monitoring. This feasibility study with timely technology development is an important and necessary step towards larger clinical studies with more subjects to further validate it for continuous monitoring and instant management of cerebral pathologies and interventions in the NICU.
Hyperspectral imaging (HSI) is increasingly used in studies for medical applications as it provides both structural and functional information of biological tissue, enhancing diagnostic accuracy and clinical decision-making. Recently, HSI cameras (HSICs) have been integrated with medical endoscopes (HSIEs), capturing hypercube data beyond conventional white light imaging endoscopes. However, there are currently no cleared or approved HSIEs by the U.S. Food and Drug Administration (FDA). HSI accuracy depends on technologies and experimental parameters, which must be assessed for reliability. Importantly, the reflectance spectrum of a target can vary across different cameras and under different environmental or operational conditions. Thus, before reliable clinical translation can be achieved, a fundamental question must be addressed: can the same target yield consistent spectral measurements across different HSI systems and under varying acquisition conditions? This study investigates the impact of eight parameters—ambient light, exposure time, camera warm-up time, spatial and temporal averaging, camera focus, working distance, illumination angle, and target angle—on spectral measurements using two HSI techniques: interferometer-based spectral scanning and snapshot. Controlled experiments were conducted to evaluate how each parameter affects spectral accuracy and whether normalization can mitigate these effects. Our findings reveal that several parameters significantly influence spectral measurements, with some having a more pronounced impact. While normalization reduced variations for most parameters, it was less effective at mitigating errors caused by ambient light and camera warm-up time. Additionally, normalization did not eliminate spectral noise resulting from low exposure time, small region of interest, or a spectrally non-uniform light source. From these results, we propose practical considerations for optimizing HSI system performance. Implementing these measures can minimize variations in reflectance spectra of identical targets captured by different cameras and under diverse conditions, thereby supporting the reliable translation of HSI techniques to clinical applications.