This study evaluated aerobic granulation and nitrogen removal via assimilation, nitrification, and denitrification of a system fed with real domestic wastewater. The granulation process was complete after 160 days of operation. The mature granules had an almost spherical structure, an average size of 473.0 μm, and a good settling ability (SVI30 of 75.6 mL g−1). Ammonium assimilation for cell growth varied between 3.5 and 64.6% during reactor start-up. After granule formation, assimilation accounted for less than 5% and nitrogen was mainly removed by partial nitrification up to nitrite, followed by denitrification via nitrite. Average efficiencies of 86.6% for nitrification, 59.5% for denitrification, and 60.5% for total nitrogen were obtained in this period. The assimilation ability of the mature granules grown on domestic wastewater was lower than the commonly reported results obtained for synthetic granules.
1 November 2013 in Journal of Environmental Engineering
Aerobic granulation has been extensively investigated in recent decades but most researchers have focused their studies on granule formation in laboratory-scale reactors using synthetic wastewaters at high organic loading rates (OLR) (OLR>2.5 kg COD·m−3·d−1). This research studied the aerobic granulation in a sequencing batch reactor (SBR) using real domestic wastewater with an OLR at or lower than 2 kg COD·m−3·d−1. The reactor was operated in three different stages (Stage I, II, and III), according to the applied OLR (1.4, 1.0, and 2.0 kg COD·m−3·d−1, respectively). After 140 days of operation (Stage II), the reactor biomass consisted mainly of compact mature granules (average diameter of 0.7 mm) with a good settling ability (SVI30 approximately 53 mL·g−1). The OLR increase caused a partial disintegration of the mature granules during the beginning of Stage III. However, the granules were able to quickly recover after the disturbance caused by the higher OLR. The reactor was effective at remo...
The effects of domestic wastewater and a coastal warm climate on granular sludge and biological nutrient removal were evaluated using a pilot-scale sequencing batch reactor (SBR). The reactor operation employed two different operational strategies (OS) based on up-flow feeding regimes, defined as fast (OS1, flow rate = 18.0 L min-1 and flow velocity = 22.0 m h-1) and slow (OS2, flow rate = 3.5 L min-1 and flow velocity = 4.3 m h-1). Under slow feeding, larger (OS1: 290 µm; OS2: 450 µm) and faster settling granules were obtained (OS1: 109; OS2: 74 mL g-1 TSS). The slow feeding regime was also advantageous for the hydrolysis of particulate organic matter (OS1: 1.3; OS2: 3.1 g CODtot g-1 VSS d-1) and for phosphorus removal (OS1: 97.5%). Neither strategy resulted in substantial biomass accumulation in the reactor (OS1: 0.7; OS2: 1.5 g VSS L-1), and high concentrations of nitrite were observed in the effluent (9-27 mg NO2--N L-1). Ordinary heterotrophic organisms dominated the granular sludge developed under both feeding regimes (OS1: 30% of Thauera; OS2: 56% of Comamonas), while polyphosphate-accumulating organisms (PAOs) were only detected during OS2 (2.3-3.4% of total bacteria). A successful granular sludge process should be able to cope with high fluctuations in wastewater loads caused by rain events (82-182 mm month-1 in Florianopolis, Brazil). In order to achieve higher water quality, strategies identified for an efficient granular sludge SBR operation included (i) management of an anaerobic phase for PAO selection, and (ii) aeration control for successful nitrification/denitrification.
Neste trabalho estudou-se a formação de grânulos aeróbios em um reator em bateladas sequenciais alimentado com esgoto doméstico e avaliou-se o desempenho desse reator em relação à remoção de carbono, nitrogênio e fósforo utilizando ciclos operacionais de 3 e 4 h. Após 150 dias de operação, a biomassa do reator era constituída predominantemente por grânulos maduros e compactos, com concentração de sólidos suspensos em torno de 1,5 g.L-1. O reator apresentou elevada capacidade de remoção de carbono, nitrogênio e fósforo, principalmente quando operado em sucessivos ciclos de 4 h, atingindo uma eficiência média de remoção de demanda química de oxigênio solúvel de 82±5%, de NH4+-N de 69±19% e de PO43--P de 30±10%.