Jaana Vanhatalo

Jaana Vanhatalo

Auto-generated profile, based on publicly available information

Jaana Vanhatalo

Department of Civil Engineering Faculty of the Built Environment Tampere University Tampere FI

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2025 in Buildings and Cities
Verified
Journal Article
Open access
PDF file
JTJonathon Taylor
Jonathon Taylor
CSCharles H. Simpson
Charles H. Simpson
JVJaana Vanhatalo
Jaana Vanhatalo
HSHasan Bin Sohail
Hasan Bin Sohail
OBOscar Brousse
Oscar Brousse
CHClare Heaviside
Clare Heaviside
Urban heat islands (UHI) modify building heating and cooling loads and public exposure to non-optimal temperatures, topics of increasing importance given climate change. This study uses personal weather stations (PWS) to investigate urban temperatures in Helsinki, Espoo, Vantaa and Tampere, Finland. Data from PWS within 50 km of municipal boundaries were acquired, cleaned and spatially linked to socio-economic, land-use and local climate zone (LCZ) classifications. Analyses evaluated for PWS location bias, including distributions across socio-economic and land-use categories. Temperatures were examined across LCZs and the urban influence on temperature, heating degree-days (HDD), cooling degree-days (CDD) and number of extreme hot or cold days calculated. Results indicate more PWS in residential open low-rise areas, but no consistent biases across incomes or ages. UHI intensities were, on average, 1.2°C (interquartile range (IQR) = 0.6–1.2°C) for Helsinki, 0.8°C (IQR = 0.4–1.2°C) for Espoo, 0.7°C (IQR = 0.4–1.1°C) for Vantaa and 0.5°C (IQR = 0.1–0.8°C) for Tampere, with differences greatest during spring and summer. Urban PWS have 112–281 fewer HDD and 30–50 more CDD than rural equivalents, suggesting a net benefit of the UHI for building energy consumption. Urban intensification of extreme heat was greater than extreme cold reduction. Practice relevance Urban climate research typically relies on sparse networks of official or researcher-deployed weather stations, interpolations thereof, land-surface temperature observations or urban climate models. However, PWS provide an additional, emerging source of data. In Finland, relatively dense and uniform PWS coverage provides opportunities to evaluate land-use impacts on urban temperatures, energy and population temperature exposures. Elevated temperatures from the UHI effect in Helsinki, Vantaa, Espoo and Tampere lead to a reduction in annual HDD around four to five times greater than the increase in CDD, as well as reduced exposure to extreme cold. Adaptation actions that aim to reduce the UHI and mitigate climate-related heat risks in colder climates may have the disbenefit of increasing energy consumption if temperature reductions also occur during heating seasons. Therefore, for cities in the far north, dynamic or seasonal adaptations such as building cooling or seasonal greenery may be preferable.


9 February 2026 in Buildings and Cities
Verified
Journal Article
Closed access
DBDalia Milián Bernal
Dalia Milián Bernal
SPSofie Pelsmakers
Sofie Pelsmakers
ENEssi Nisonen
Essi Nisonen
JVJaana Vanhatalo
Jaana Vanhatalo

14 January 2026 in Buildings and Cities
Verified
Journal Article
Open access
PDF file
JTJonathon Taylor
Jonathon Taylor
LTLevin Thoen
Levin Thoen
AVAlonso Espinosa Mireles de Villafranca
Alonso Espinosa Mireles de Villafranca
PAPetr Anashin
Petr Anashin
JVJaana Vanhatalo
Jaana Vanhatalo
IOIida Okkonen
Iida Okkonen
In Europe, remote work is increasing, driven by technological advances and behavioural shifts. Working from home may potentially reduce commuting-related greenhouse gas (GHG) emissions, but can also remove incidental physical activity during commutes. Alternative work locations, such as co-working spaces, are a third option, with potential impacts on travel-related emissions and physical activity. This paper examines commuting behaviours of remote workers in Finland to their employer and alternative work locations, assessing differences in distances, modes and active travel levels; characterising different types of remote workers; and mapping how co-working spaces can support 15-min cities in the Helsinki Metropolitan Area. A survey collected remote worker socio-demographic characteristics, and the mode and frequency of travel between home and work locations. Travel time, distance, and emissions were estimated and compared between work locations, and used to develop remote worker typologies using clustering analysis, while spatial analysis was used to locate potential future co-working spaces to leverage potential benefits. Results show those working from designated alternative workspaces had lower single-trip emissions and were more likely to use active travel than those travelling to employer offices. However, long-distance travel for remote work at cottages or holiday homes resulted in high emission rebound effects. POLICY RELEVANCE Remote working has the potential to reduce commuting-related GHG emissions, but may also increase sedentary behaviour as workers stay at home, and often with poor ergonomics. Alternative third workspaces such as co-working spaces appear to offer a compromise, with shorter commuting distances reducing potential emissions and increasing the likelihood of using active travel, as well as better ergonomic environments. However, remote working from third locations may also facilitate rebound travel behaviours, where individuals travel to distant remote work locations. Policies supporting local co-working spaces, and their strategic placement, may offer a potential remote work compromise which encourages more physical activity. Through understanding the types and travel behaviours of people who work remotely, it may be possible to strategically locate co-working spaces to encourage low emission and active commuting and help support the 15-min city concept by shifting work locations.