25 January 2021 in IEEE Transactions on Instrumentation and Measurement
Classical absolute gravimeters are widely used in many areas, including metrology, seismology, geophysics, and exploration. These gravimeters apply a free-fall method to measure absolute gravitational acceleration using a laser interferometer. In practice, the measurement precision is affected by ground vibrations. Vibration correction is an important way to deal with these ground vibrations for absolute gravity measurement. Most vibration correction methods use a commercial seismometer to measure the motion of a reference retroreflector indirectly. A vertical seismometer with a built-in retroreflector is designed to directly measure the motion of the retroreflector, which is fixed on the proof mass of the seismometer. The motion of the retroreflector relative to the ground vibration is measured through capacitance detection. A voice coil actuator is employed to drive the retroreflector to track the ground vibration. The sensitivity of the homemade vertical seismometer is approximately 15751 V/g. The bandwidth of the system is 80 Hz. The homemade vertical seismometer is integrated into the homemade T-1 absolute gravimeter to test its performance. The standard deviation of the measurement results is reduced by a factor of 16, when compared with the results obtained without any vibration treatment. Absolute gravimeters with the homemade vertical seismometer are expected to be used in field measurements.
18 March 2021 in IEEE Transactions on Instrumentation and Measurement
Accurate absolute gravimeters are important instruments in applications, such as metrology, geophysics, and geological exploration. Vibration is one of the limiting factors that cause deterioration in measurement accuracy, which includes trueness and precision. The vibration correction method, in which a seismometer is used to record the vibration, provides an effective method to deal with the disturbances. The theoretical analysis shows that the ultimate correction accuracy is limited by the inherent frequency performance of the seismometer. The correction algorithm is an optimization problem to achieve this ultimate accuracy. The selection of the optimization objectives affects the correction accuracy dramatically. Although the real gravitational acceleration is unknown before the measurement is taken, minimization of the standard deviation of the fitting residual for a single drop (SDFRSD) is proven to realize better trueness. Enhanced precision is achieved through minimization of the Type A uncertainty of gravitational accelerations for all drops (UGAAD). Simulations and experimental measurements with the T-1 absolute gravimeter verify the theoretical analysis results. In addition, the results also show that the SDFRSD correction contains the real gravitational acceleration value, while the UGAAD correction exceeds the valid range. Therefore, the SDFRSD correction approach provides better comprehensive accuracy than the UGAAD correction method.
21 December 2020 in IEEE Transactions on Instrumentation and Measurement
Accurate observations of the gravitational acceleration ( $g$ , about 9.8 m/s 2 ) provide important geophysical data for use in geophysics, metrology, and geodesy. At present, the most widely used absolute gravimeter determines the value of $g$ by tracking a falling retroreflector in a vacuum using a laser interferometer. The precision and accuracy of the measurement are mainly affected by ground vibration noise. When compared with a vibration isolator, vibration correction offers a simple and convenient way to reduce the influence of ground vibrations. Previous correction methods have used a low-noise seismometer as a detector. However, their performance is limited by the seismometer’s bandwidth (which usually ranges from 0.01 to 60 Hz). An optimized correction method combined with digital filtering is proposed here to increase the seismometer’s bandwidth numerically. Experimental results show that the accuracy and precision of the corrected results using the optimized method are improved in both relatively quiet and complex vibration environments. And better improvement is shown in complex vibration environment. Therefore, both the feasibility and the superiority of the proposed method have been verified. Further improvements can be achieved by using a higher-order digital filter.
18 July 2022 in IEEE Transactions on Instrumentation and Measurement
Dynamic onboard gravimetry is essential in geophysics, geodesy, and exploration. Optical interferometry is one of the promising technologies to achieve dynamic absolute gravimetry. A vibration correction system aimed at dynamic optical absolute gravimetry is proposed in this article. Its performance is preliminarily verified in static condition on the ground and on a passive gimbal suspension, respectively. As for case on the ground, the standard deviation is reduced from 7.5 to 0.9 mGal and the systematic deviation is reduced from 1.3 to 0.3 mGal after correction. As for case on the gimbal, the amplitude of vibration noise is up to 0.1 m/s 2 which is close to the intensity of vibrations onboard. The standard deviation is reduced from 43 to 1.3 mGal, and the systematic deviation is reduced from 83 to 0.2 mGal after correction. A precision of 3–4 mGal/ $\surd $ Hz could thus be achieved by proposed system. The error sources of the system are also analyzed, a combined standard uncertainty of 0.5 mGal is considered to be obtained. These results show a promise of achieving satisfying measurements for future dynamic experiments.
3 April 2023 in IEEE Transactions on Instrumentation and Measurement
The absolute gravimeters used in gravity measurements have wide applications across disciplines. The precision of a classical free-fall absolute gravimeter is limited by the performance of its dropping mechanism. The mismatch between the linear bearings and guideways can give rise to vibrations in measurement and lead to errors in the gravity results. To detect this problem, this research develops a diagnostic approach based on the current analysis of the motor that drives the dropping mechanism. Several dropping chambers are tested under gravity measurement within 12 hours to calculate the uncertainty of the mean and be tagged as qualified or unqualified. The status of the dropping mechanism is assessed by applying four parameters of the current data in the time and frequency domains during steady motion and feature coefficients of transient current under wavelet packet decomposition (WPD). The proper ranges of the parameters are identified through comparative experiments. Empirical evidence confirms the feasibility of the parameters and coefficients used to determine whether a gravimeter dropping mechanism meets the requirement of precision around 1 micro Gal. In addition, the analysis based on continuous wavelet transform (CWT) proves its potential to locate the faults in the unqualified dropping mechanism. The proposed diagnostic approach can be applied within 20 times of motor current acquisition, which makes it practicable and helpful in improving and achieving high-precision gravity measurement.